Iris Thickness and Severity of Neovascular Glaucoma Determined Using Swept-Source Anterior-segment Optical Coherence Tomography

被引:7
|
作者
Nakakura, Shunsuke [1 ]
Kobayashi, Yui [1 ]
Matsuya, Kanae [1 ]
Terao, Etsuko [1 ]
Kiuchi, Yoshiaki [2 ]
机构
[1] Saneikai Tsukazaki Hosp, Dept Ophthalmol, 68-1 Aboshi Waku, Himeji, Hyogo 6711227, Japan
[2] Hiroshima Univ, Grad Sch Biomed Sci, Dept Ophthalmol & Visual Sci, Hiroshima, Japan
关键词
neovascular glaucoma; peripheral anterior synechia; anterior-segment optical coherence tomography; panretinal photocoagulation; iris thickness; MACULAR CHOROIDAL THICKNESS; GROWTH-FACTOR THERAPY; PHOTOCOAGULATION; ANGLE; EYES;
D O I
10.1097/IJG.0000000000000921
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the iris thickness (IT) in neovascular glaucoma (NVG) using swept-source anterior-segment optical coherence tomography (ASOCT). Patients and Methods: In this retrospective, clinic-based, comparative study, we enrolled 20 NVG patients [11 with 360-degree angle-closure (AC)-NVG and 9 with NVG without AC] and 14 healthy age-matched controls. Horizontal scanning images of swept-source ASOCT were analyzed using software calipers in temporal and nasal angle areas. ITs at 1 and 2 mm from the pupil edge were measured using ASOCT. The relation between IT and the severity of NVG, the effects of intraocular pressure (IOP), intravitreal antivascular endothelial growth factor (anti-VEGF) injection, and panretinal photocoagulation (PRP) were assessed using linear regression analysis based on the corrected Akaike information criteria index. Results: The IT was thinner in 360-degree AC-NVG patients, followed by NVG patients without AC and controls (0.33 vs. 0.48 vs. 0.57mm at 1 mm and 0.31 vs. 0.43 vs. 0.49 mm at 2 mm; P < 0.001 by ANOVA). Multiple linear regression analysis revealed that 360-degree AC-NVG patients-NVG patients without AC and controls (coefficient: -0.16), NVG patients without AC-control (-0.13) and underwent PRP (0.23) at 1 mm, 360-degree AC-NVG patients-NVG patients without AC and controls (-0.12), NVG patients without AC-controls (-0.08), underwent PRP (0.16), received anti-VEGF injection (0.05) and IOP (-0.001) at 2 mm were selected predictors to explain IT. Conclusions: IT decreases with the progression of the NVG stage and is thinnest in 360-degree AC-NVG patients. Our study suggests a new morphologic feature of NVG.
引用
收藏
页码:415 / 420
页数:6
相关论文
共 50 条
  • [1] Determination of iris thickness development in children using swept-source anterior-segment optical coherence tomography
    Nakakura, Shunsuke
    Nagata, Yuki
    Shimizu, Yukiko
    Kawai, Akiko
    Tabuchi, Hitoshi
    Kiuchi, Yoshiaki
    [J]. PLOS ONE, 2019, 14 (05):
  • [2] Pigmented Iris Lesion on Anterior-Segment Swept-Source Optical Coherence Tomography
    Vaidya, Sarangdev
    Yaghy, Antonio
    Shields, Carol L.
    [J]. JAMA OPHTHALMOLOGY, 2021, 139 (01)
  • [3] Measurement of Iris Lesion Volume with Anterior Segment Swept-Source Optical Coherence Tomography
    Vickers, Laura
    Akil, Handan
    Baghdasaryan, Elmira
    Lee, Olivia L.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [4] Bilateral Acute Depigmentation of the Iris: Findings in Anterior Segment Swept-Source Optical Coherence Tomography
    Escribano Lopez, Patricia
    Jacobo Gonzalez-Guijarro, J.
    [J]. OCULAR IMMUNOLOGY AND INFLAMMATION, 2019, 27 (08) : 1288 - 1292
  • [5] Anterior segment swept-source optical coherence tomography and ultrasound biomicroscopy in iris and ciliary body lesions
    Mirzayev, Ibadulla
    Gunduz, Ahmet Kaan
    Gunduz, Omur Ozlenen
    Ates, Funda Seher Ozalp
    Heper, Aylin Okcu
    [J]. EXPERT REVIEW OF MEDICAL DEVICES, 2024,
  • [6] Anterior scleral thickness dimensions by swept-source optical coherence tomography
    Ignacio Fernandez-Vigo, Jose
    Shi, Hang
    Burgos-Blasco, Barbara
    Fernandez-Aragon, Susana
    De-Pablo-Gomez-de-Liano, Lucia
    Kudsieh, Bachar
    Macarro-Merino, Ana
    Angel Fernandez-Vigo, Jose
    [J]. CLINICAL AND EXPERIMENTAL OPTOMETRY, 2022, 105 (01) : 13 - 19
  • [7] Anterior Segment Angiography with 1050 nm Swept-Source Optical Coherence Tomography
    Li, Yan
    Lu, Chen D.
    Jia, Yali
    Lee, ByungKun
    Kraus, Martin F.
    Hornegger, Joachim
    Fujimoto, James G.
    Huang, David
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [8] Corneal thickness mapping by 3D swept-source anterior segment optical coherence tomography
    Neri, Alberto
    Malori, Marianna
    Scaroni, Patrizia
    Leaci, Rosachiara
    Delfini, Elisabetta
    Macaluso, Claudio
    [J]. ACTA OPHTHALMOLOGICA, 2012, 90 (06) : e452 - e457
  • [9] Tear Meniscus Evaluation by Anterior Segment Swept-Source Optical Coherence Tomography
    Fukuda, Reina
    Usui, Tomohiko
    Miyai, Takashi
    Yamagami, Satoru
    Amano, Shiro
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 155 (04) : 620 - 624
  • [10] Polarization sensitive corneal and anterior segment swept-source optical coherence tomography
    Lim, Yiheng
    Yamanari, Masahiro
    Yasuno, Yoshiaki
    [J]. OPHTHALMIC TECHNOLOGIES XX, 2010, 7550