Calibration of a portal imaging device for high-precision dosimetry: A Monte Carlo study

被引:23
|
作者
Keller, H [1 ]
Fix, M [1 ]
Ruegsegger, P [1 ]
机构
[1] ETH Zurich, Inst Biomed Engn, Zurich, Switzerland
关键词
electronic portal imaging; liquid filled ionization chambers; dose calibration; Monte Carlo simulation;
D O I
10.1118/1.598378
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Today electronic portal imaging devices (EPID's) are used primarily to verify patient positioning. They have, however, also the potential as 2D-dosimeters and could be used as such for transit dosimetry or dose reconstruction. It has been proven that such devices, especially liquid filled ionization chambers, have a stable dose response relationship which can be described in terms of the physical properties of the EPID and the pulsed linac radiation. For absolute dosimetry however, an accurate method of calibration to an absolute dose is needed. In this work, we concentrate on calibration against dose in a homogeneous water phantom. Using a Monte Carlo model of the detector we calculated dose spread kernels in units of absolute dose per incident energy fluence and compared them to calculated dose spread kernels in water at different depths. The energy of the incident pencil beams varied between 0.5 and 18 MeV. At the depth of dose maximum in water for a 6 MV beam (1.5 cm) and for a Is MV beam (3.0 cm) we observed large absolute differences between water and detector dose above an incident energy of 4 MeV but only small relative differences in the most frequent energy range of the beam energy spectra. It is shown that for a 6 MV beam the absolute reference dose measured at 1.5 cm water depth differs from the absolute detector dose by 3.8%. At depth 1.2 cm in water, however, the relative dose differences are almost constant between 2 and 6 MeV. The effects of changes in the energy spectrum of the beam on the dose responses in water and in the detector are also investigated. We show that differences larger than 2% can occur for different beam qualities of the incident photon beam behind water slabs of different thicknesses. It is therefore concluded that for high-precision dosimetry such effects have to be taken into account. Nevertheless, the precise information about the dose response of the detector provided in this Monte Carlo study forms the basis of extracting directly the basic radiometric quantities photon fluence and photon energy fluence from the detector's signal using a deconvolution algorithm. The results are therefore promising for future application in absolute transit dosimetry and absolute dose reconstruction. (C) 1998 American Association of Physicists in Medicine. [S0094-2405(98)02210-X].
引用
收藏
页码:1891 / 1902
页数:12
相关论文
共 50 条
  • [41] The use of an electronic portal imaging device for exit dosimetry
    Conte, L
    Stucchi, P
    Mordacchini, C
    Bianchi, C
    Monciardini, M
    Novario, R
    Cassani, E
    Mantovani, R
    Antognoni, P
    Tordiglione, M
    PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, 1997, : 279 - 281
  • [42] Development of an Electronic Portal Imaging Device Dosimetry Method
    Zhang, Jun
    Fan, Ziting
    Zhang, Xile
    Yang, Ruijie
    Wen, Junhai
    DIAGNOSTICS, 2021, 11 (09)
  • [43] Study on high-precision imaging method of carbonate reservoir
    Gu B.
    Han J.
    Chen J.
    Huang J.
    Li Z.
    Dizhi Xuebao/Acta Geologica Sinica, 2020, 94 (08): : 2534 - 2544
  • [44] Evaluation of an electronic portal imaging device for transit dosimetry
    He, Xiaodong
    Esch, Ann Van
    Reymen, Rita
    Huyskens, Dominique
    Acta Oncologica, 38 (05): : 591 - 596
  • [45] Optimization of an electric field calibration chamber for high-precision measurements for imaging applications
    Adelman, Ross
    Pritchett, Timothy M.
    Hull, David M.
    George, Alex
    Heintzelman, Sean
    JOURNAL OF ELECTROSTATICS, 2024, 130
  • [46] DEVICE FOR TESTING HIGH-PRECISION VOLTMETERS
    VERBENKO, EG
    MEASUREMENT TECHNIQUES-USSR, 1967, (04): : 505 - &
  • [47] High-Precision Monte Carlo Simulation of the Ising Models on the Penrose Lattice and the Dual Penrose Lattice
    Komura, Yukihiro
    Okabe, Yutaka
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 2016, 85 (04)
  • [48] Calibration of portal imaging devices for radiotherapy in-vivo dosimetry
    Piermattei, Angelo
    Cilla, Savino
    Fidanzio, Andrea
    Greco, Francesca
    Sabatino, Domenico
    Gargiulo, Laura
    Azario, Luigi
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 623 (02): : 829 - 831
  • [49] A High-Precision Calibration Method for MEMS Gyroscopes
    Shang, Zhigang
    Ma, Xiaochuan
    Li, Mo
    Liu, Yu
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2015, 16 (08) : 1711 - 1716
  • [50] Calibration of the TWIST high-precision drift chambers
    Grossheim, A.
    Hu, J.
    Olin, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 623 (03): : 954 - 959