The LNLS soft X-ray spectroscopy beamline

被引:27
|
作者
Tolentino, H [1 ]
Compagnon-Cailhol, V [1 ]
Vicentin, FC [1 ]
Abbate, M [1 ]
机构
[1] CNPq, LNLS, BR-13083970 Campinas, SP, Brazil
关键词
soft X-rays; spectroscopy; beamline optics;
D O I
10.1107/S0909049597016087
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The soft X-ray spectroscopy beamline installed at a bending-magnet source at the LNLS is described. The optics are designed to cover energies from 800 to 4000 eV with good efficiency. The focusing element is a gold-coated toroidal mirror with an angle of incidence of 17 mrad. The UHV double-crystal monochromator has three pairs of crystals, Si (111), InSb (111) and beryl (10 (1) over bar 0), that can be selected by a sliding movement. The UHV workstation is equipped with an ion gun, an electron gun, an electron analyser, LEED optics, an open channeltron and a photodiode array. This beamline is intended for photoemission. photoabsorption, reflectivity and dichroism experiments.
引用
收藏
页码:539 / 541
页数:3
相关论文
共 50 条
  • [1] The LNLS soft X-ray spectroscopy beamline
    Tolentino, H.
    Compagnon-Cailhol, V.
    Vicentin, F.C.
    Abbate, M.
    Journal of Synchrotron Radiation, 1998, 5 (03): : 539 - 541
  • [2] The soft X-ray spectroscopy beamline at the LNLS: technical description and commissioning results
    Abbate, M
    Vicentin, FC
    Compagnon-Cailhol, V
    Rocha, MC
    Tolentino, H
    JOURNAL OF SYNCHROTRON RADIATION, 1999, 6 : 964 - 972
  • [3] The Dispersive X-ray Absorption Spectroscopy beamline at LNLS
    Tolentino, Helio C. N.
    Cezar, Julio C.
    Watanabe, Noemia
    Piamonteze, Cinthia
    Souza-Neto, Narcizo M.
    Tamura, Edilson
    Ramos, AlineY.
    Neueschwander, Regis
    PHYSICA SCRIPTA, 2005, T115 : 977 - 979
  • [4] Micro-soft x-ray spectroscopy with the LUCIA beamline
    Lagarde, P.
    Flank, A. -M.
    Vantelon, D.
    Janousch, M.
    X-RAY ABSORPTION FINE STRUCTURE-XAFS13, 2007, 882 : 852 - +
  • [5] A DEDICATED SOFT-X-RAY BEAMLINE FOR X-RAY ABSORPTION-SPECTROSCOPY
    MORRISON, TI
    LIEN, NC
    BUNKER, BA
    SAYERS, DE
    HEALD, SM
    FARERIA, L
    SCROFANI, J
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07): : 1991 - 1991
  • [6] Synchrotron radiation x-ray fluorescence at the LNLS:: Beamline instrumentation and experiments
    Pérez, CA
    Radtke, M
    Sánchez, HJ
    Tolentino, H
    Neuenshwander, RT
    Barg, W
    Rubio, M
    Bueno, MIS
    Raimundo, IM
    Rohwedder, JJR
    X-RAY SPECTROMETRY, 1999, 28 (05) : 320 - 326
  • [7] Soft x-ray spectroscopy undulator beamline at the Advanced Photon Source
    Randall, KJ
    Xu, ZD
    Moore, JF
    Gluskin, E
    GRATINGS AND GRATING MONOCHROMATORS FOR SYNCHROTRON RADIATION, 1997, 3150 : 189 - 194
  • [8] Soft X-ray beamline for spectroscopy of solids at SPring-8
    Saitoh, Y
    Kimura, H
    Suzuki, Y
    Nakatani, T
    Matsushita, T
    Muro, T
    Miyahara, T
    Fujisawa, A
    Soda, K
    Ueda, S
    Sekiyama, A
    Imada, S
    Suga, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 553 - 556
  • [9] PHELIX - A new soft X-ray spectroscopy beamline at SOLARIS synchrotron
    Szczepanik-Ciba, Magdalena
    Sobol, Tomasz
    Szade, Jacek
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2021, 492 : 49 - 55
  • [10] CARNAUBA: The Coherent X-Ray Nanoprobe Beamline for the Brazilian Synchrotron SIRIUS/LNLS
    Tolentino, Helio C. N.
    Soares, Marcio M.
    Perez, Carlos A.
    Vicentin, Flavio C.
    Abdala, Dalton B.
    Galante, Douglas
    Teixeira, Veronica de C.
    de Araujo, Douglas H. C.
    Westfahl, Harry, Jr.
    X-RAY MICROSCOPY CONFERENCE 2016 (XRM 2016), 2017, 849