Synchrotron radiation x-ray fluorescence at the LNLS:: Beamline instrumentation and experiments

被引:0
|
作者
Pérez, CA
Radtke, M
Sánchez, HJ [1 ]
Tolentino, H
Neuenshwander, RT
Barg, W
Rubio, M
Bueno, MIS
Raimundo, IM
Rohwedder, JJR
机构
[1] Univ Nacl Cordoba, Fac Matemat Astron & Fis, RA-5000 Cordoba, Argentina
[2] Lab Nacl Luz Sincrotron, CNPq, BR-13038970 Campinas, SP, Brazil
[3] UNICAMP, Inst Quim, BR-13083970 Campinas, SP, Brazil
关键词
D O I
10.1002/(SICI)1097-4539(199909/10)28:5<320::AID-XRS359>3.0.CO;2-1
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The x-ray fluorescence beamline of the Laboratorio Nacional de Luz Sincrotron (LNLS) is described, The main optical component of the beamline is a silicon (111) channel-cut monochromator, which can tune energies between 3 and 14 keV. A general description of two experimental stations is given, Beam characterization was done by measuring experimental parameters such as vertical profile and monochromatic Bur. These results show that the photon flux at 8 keV in an area of 20 mm(2) is 4.2 x 10(9) photons s(-1). The possibility of achieving fine tuning of energies (high resolution) was confirmed, This paper presents some original results derived from the commissioning of the beamline, such as a comparison of detection limits in different experimental conditions, and a novel mechanical system to align capillaries together with a semi-automatic adjustment procedure. So far, there have been several proposals to perform a variety of experiments at this beamline. covering different fields, such as physics, chemistry, geology and biology. Copyright (C) 1999 John Whey & Sons, Ltd.
引用
收藏
页码:320 / 326
页数:7
相关论文
共 50 条
  • [1] CARNAUBA: The Coherent X-Ray Nanoprobe Beamline for the Brazilian Synchrotron SIRIUS/LNLS
    Tolentino, Helio C. N.
    Soares, Marcio M.
    Perez, Carlos A.
    Vicentin, Flavio C.
    Abdala, Dalton B.
    Galante, Douglas
    Teixeira, Veronica de C.
    de Araujo, Douglas H. C.
    Westfahl, Harry, Jr.
    X-RAY MICROSCOPY CONFERENCE 2016 (XRM 2016), 2017, 849
  • [2] The LNLS soft X-ray spectroscopy beamline
    Tolentino, H
    Compagnon-Cailhol, V
    Vicentin, FC
    Abbate, M
    JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 539 - 541
  • [3] The LNLS soft X-ray spectroscopy beamline
    Tolentino, H.
    Compagnon-Cailhol, V.
    Vicentin, F.C.
    Abbate, M.
    Journal of Synchrotron Radiation, 1998, 5 (03): : 539 - 541
  • [4] The X-ray Fluorescence Microscopy Beamline at the Australian Synchrotron
    Paterson, D.
    de Jonge, M. D.
    Howard, D. L.
    Lewis, W.
    McKinlay, J.
    Starritt, A.
    Kusel, M.
    Ryan, C. G.
    Kirkham, R.
    Moorhead, G.
    Siddons, D. P.
    10TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2011, 1365 : 219 - 222
  • [5] The Dispersive X-ray Absorption Spectroscopy beamline at LNLS
    Tolentino, Helio C. N.
    Cezar, Julio C.
    Watanabe, Noemia
    Piamonteze, Cinthia
    Souza-Neto, Narcizo M.
    Tamura, Edilson
    Ramos, AlineY.
    Neueschwander, Regis
    PHYSICA SCRIPTA, 2005, T115 : 977 - 979
  • [6] A microfocus X-ray fluorescence beamline at Indus-2 synchrotron radiation facility
    Tiwari, M. K.
    Gupta, P.
    Sinha, A. K.
    Kane, S. R.
    Singh, A. K.
    Garg, S. R.
    Garg, C. K.
    Lodha, G. S.
    Deb, S. K.
    JOURNAL OF SYNCHROTRON RADIATION, 2013, 20 : 386 - 389
  • [7] The X-ray fluorescence beamline at Brazilian National Synchrotron Laboratory
    Pérez, CA
    Radtke, M
    Tolentino, H
    Vicentin, FC
    Neuenshwander, RT
    Barg, B
    Sánchez, HJ
    Rubio, M
    Bueno, MIS
    Raimundo, IM
    Rohwedder, JJR
    EDXRS-98: PROCEEDINGS OF THE EUROPEAN CONFERENCE ON ENERGY DISPERSIVE X-RAY SPECTROMETRY 1998, 1999, : 125 - 129
  • [8] Simultaneous X-ray fluorescence and scanning X-ray diffraction microscopy at the Australian Synchrotron XFM beamline
    Jones, Michael W. M.
    Phillips, Nicholas W.
    van Riessen, Grant A.
    Abbey, Brian
    Vine, David J.
    Nashed, Youssef S. G.
    Mudie, Stephen T.
    Afshar, Nader
    Kirkham, Robin
    Chen, Bo
    Balaur, Eugeniu
    de Jonge, Martin D.
    JOURNAL OF SYNCHROTRON RADIATION, 2016, 23 : 1151 - 1157
  • [9] Control of x-ray beam fluctuation in synchrotron radiation lithography beamline
    Shimano, Hiroki
    Tanaka, Hirofumi
    Ozaki, Yoshihiko
    Marumoto, Kenji
    Japanese Journal of Applied Physics, Part 1: Regular Papers & Short Notes & Review Papers, 1995, 34 (10): : 5856 - 5861
  • [10] X-RAY INSTRUMENTATION FOR BIOLOGICAL CRYSTALLOGRAPHY USING SYNCHROTRON RADIATION
    KAHN, R
    BOSSHARD, R
    FOURME, R
    X-RAY INSTRUMENTATION IN MEDICINE AND BIOLOGY, PLASMA PHYSICS, ASTROPHYSICS, AND SYNCHROTRON RADIATION, 1989, 1140 : 68 - 72