Dual-Energy CT of Material Decomposition Analysis for Detection with Bone Marrow Edema in Patients with Vertebral Compression Fractures

被引:18
|
作者
Akisato, Kyouhei [1 ]
Nishihara, Reisuke [2 ]
Okazaki, Hajime [2 ]
Masuda, Takanori [3 ]
Hironobe, Ayako [2 ]
Ishizaki, Hiromi [2 ]
Shota, Kondo [2 ]
Yamaguchi, Hiroshi [1 ]
Funama, Yoshinori [4 ]
机构
[1] JA Hiroshima Gen Hosp, Dept Radiol, Hatsukaichi, Hiroshima, Japan
[2] JA Hiroshima Gen Hosp, Dept Diagnost Imaging, Hatsukaichi, Hiroshima, Japan
[3] Tsuchiya Gen Hosp, Dept Radiol Technol, Naka Ku, 3-30 Nakajima Cho, Hiroshima 7308655, Japan
[4] Kumamoto Univ, Fac Life Sci, Dept Med Phys, Kumamoto, Japan
关键词
Dual energy; Dual-energy material density analysis images; Bone marrow edema; Vertebral compression fractures; PERCUTANEOUS VERTEBROPLASTY; DIAGNOSTIC PERFORMANCE; MANAGEMENT; LESIONS; OSTEOPOROSIS; IMPACT; WOMEN; CARE;
D O I
10.1016/j.acra.2019.02.015
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: This study investigated detecting bone marrow edema (BME) in patients with vertebral compression fractures. We compared dual-energy material density analysis images to magnetic resonance imaging (MRI), which is considered the gold standard. Materials and Methods: In this retrospective study, 260 vertebral bodies from 30 patients (11 males, 19 females, mean age of 81) were assessed by MRI and dual-energy material density analysis. Diagnostic accuracy was assessed using the receiver operating characteristic (ROC) curve. Fifty-two of the 260 vertebral bodies were considered to have BME based on the dual-energy material density analysis images; 50 were deemed to have BME by MRI. Results: ROC analysis of the dual-energy material density analysis values revealed an area under the ROC curve of 0.95 for radiologist 1, 0.97 for radiologist 2, and 0.96 for radiologist 3. A mean cutoff value of 1032.6 mg/cm(3) provided an overall sensitivity of 93.0% (95% confidence intervals [CI]: 86.0%-99.9%), specificity of 98.0% (95% CI: 95.5%-99.0%), accuracy of 97.0% (95% CI: 95.2%-99.0%), positive predictive value of 95.0% (95% CI: 81.0%-97.5%), and negative predictive value of 98.0% (95% CI: 93.0% -99.9%). Conclusion: BME in patients with vertebral compression fractures can be detected using dual-energy material density analysis images.
引用
收藏
页码:227 / 232
页数:6
相关论文
共 50 条
  • [31] Quantification of bone marrow edema using dual-energy CT at fracture sites in trauma
    Mashya Abbassi
    Ashwin Jain
    Donghoon Shin
    Carlota Andreu Arasa
    Baojun Li
    Stephan W. Anderson
    Christina A. LeBedis
    Emergency Radiology, 2022, 29 : 691 - 696
  • [32] Dual-Energy Computed Tomographic Virtual Noncalcium Algorithm for Detection of Bone Marrow Edema in Acute Fractures: Early Experiences
    Reagan, Adrian C.
    Mallinson, Paul I.
    O'Connell, Timothy
    McLaughlin, Patrick D.
    Krauss, Bernhard
    Munk, Peter L.
    Nicolaou, Savvas
    Ouellette, Hugue A.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2014, 38 (05) : 802 - 805
  • [33] Utilization of a two-material decomposition from a single-source, dual-energy CT in acute traumatic vertebral fractures
    Tivnan, Patrick
    Kaliaev, Artem
    Anderson, Stephan W.
    LeBedis, Christina A.
    Li, Baojun
    Andreu-Arasa, V. Carlota
    FRONTIERS IN RADIOLOGY, 2023, 3
  • [34] Detection of Bone Marrow Edema in Patients with Osteoid Osteoma Using Three-Material Decomposition with Dual-Layer Spectral CT
    Gassert, Florian T.
    Hammel, Johannes
    Hofmann, Felix C.
    Neumann, Jan
    von Schacky, Claudio E.
    Gassert, Felix G.
    Pfeiffer, Daniela
    Pfeiffer, Franz
    Makowski, Marcus R.
    Woertler, Klaus
    Gersing, Alexandra S.
    Schwaiger, Benedikt J.
    DIAGNOSTICS, 2021, 11 (06)
  • [35] The Clinical Utility of Lower Extremity Dual-Energy CT Angiography in the Detection of Bone Marrow Edema in Diabetic Patients with Peripheral Artery Disease
    Floridi, Chiara
    Cacioppa, Laura Maria
    Valeri, Tommaso
    Rossini, Nicolo
    Rosati, Marzia
    Vento, Vincenzo
    Felicioli, Alessandro
    Macchini, Marco
    Candelari, Roberto
    Carotti, Marina
    Giovagnoni, Andrea
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (06)
  • [36] Noise Suppression in Material Decomposition for Dual-Energy CT
    Dong, X.
    Petrongolo, M.
    Wang, T.
    Zhu, L.
    MEDICAL PHYSICS, 2014, 41 (06) : 541 - 541
  • [37] Dual-Energy Computed Tomography-Based Display of Bone Marrow Edema in Incidental Vertebral Compression Fractures Diagnostic Accuracy and Characterization in Oncological Patients Undergoing Routine Staging Computed Tomography
    Frellesen, Claudia
    Azadegan, Mehrnoush
    Martin, Simon S.
    Otani, Katharina
    D'Angelo, Tommaso
    Booz, Christian
    Eichler, Katrin
    Panahi, Bita
    Kaup, Moritz
    Bauer, Ralf W.
    Vogl, Thomas J.
    Wichmann, Julian L.
    INVESTIGATIVE RADIOLOGY, 2018, 53 (07) : 409 - 416
  • [38] Identification of bone marrow edema of the knee: diagnostic accuracy of dual-energy CT in comparison with MRI
    Giovanni Foti
    William Mantovani
    Niccolò Faccioli
    Giacomo Crivellari
    Luigi Romano
    Claudio Zorzi
    Giovanni Carbognin
    La radiologia medica, 2021, 126 : 405 - 413
  • [39] Identification of bone marrow edema of the ankle: diagnostic accuracy of dual-energy CT in comparison with MRI
    Foti, Giovanni
    Catania, Matteo
    Caia, Simone
    Romano, Luigi
    Beltramello, Alberto
    Zorzi, Claudio
    Carbognin, Giovanni
    RADIOLOGIA MEDICA, 2019, 124 (10): : 1028 - 1036
  • [40] Identification of bone marrow edema of the knee: diagnostic accuracy of dual-energy CT in comparison with MRI
    Foti, Giovanni
    Mantovani, William
    Faccioli, Niccolo
    Crivellari, Giacomo
    Romano, Luigi
    Zorzi, Claudio
    Carbognin, Giovanni
    RADIOLOGIA MEDICA, 2021, 126 (03): : 405 - 413