Effect of Wall Exhaust and Spill Locations on Indoor Air Quality in a Chemical Laboratory

被引:0
|
作者
Morcos, Ayman A. Shaaban Samy M. [1 ]
Khalil, Essam E. [1 ]
Fouad, Mahmoud A. [1 ]
机构
[1] Cairo Univ, Fac Engn, Mech Power Dept, Giza 12211, Egypt
来源
关键词
CONTAMINANT DISTRIBUTION; MIXING VENTILATION; ROOM AIR; ENVIRONMENTS; INLET;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Indoor air quality inside chemical laboratories subjected to gaseous contaminants was investigated numerically throughout the current research using Ansys Fluent 13. The lab is 4.8 m (L) * 4.3 m (W) * 2.73 m (H). The model was built and mesh was generated using Gambit 2.2.30 yielding around 1.4 million cells. To ensure the reliability of the Computational Fluid Dynamics (CFD) model validation was done against experimental data of three cases done by Jin et al. [1]. The model could simulate accurately contaminant mole fraction to the order of 10(-7) with average absolute error of 9% using Re-normalization group (RNG) k-epsilon turbulence model. Parametric study is done to investigate the effect of wall exhaust and spill locations on the efficiency of the ventilation system. Wall exhaust location had strong impact on the contaminant distribution within the laboratory. Using wall exhaust in same half where the spill occurs was a very efficient solution for contaminant removal in accidents. The spill location did not have strong impact on the indoor air quality inside chemical laboratories. Average absolute deviation percentage in the average contaminant concentration in the studied cases because of the change of the spill location is 5% with maximum deviation percentage of 14%. This was attributed to the good mixing achieved by high Air Changes per Hour (ACH) normally used in laboratories (6 - 12).
引用
收藏
页数:8
相关论文
共 50 条
  • [1] A Study on the Effect of Exhaust Gases on the Indoor Air Quality Onboard Ships
    Abdullah, Hayati
    Ariffin, Arman
    [J]. ADVANCES IN THERMOFLUIDS, 2013, 388 : 106 - +
  • [2] Indoor air quality - Chemical pollutants
    Senitkova, I
    [J]. INTERNATIONAL SYMPOSIUM ON AIR CONDITIONING IN HIGH RISE BUILDINGS '2000, PROCEEDINGS, 2000, 2000 (03): : 183 - 185
  • [3] Effects of inlet and exhaust locations and emitted gas density on indoor air contaminant concentrations
    Khan, JA
    Feigley, CE
    Lee, E
    Ahmed, MR
    Tamanna, S
    [J]. BUILDING AND ENVIRONMENT, 2006, 41 (07) : 851 - 863
  • [4] A METHOD TO SELECT LOCATIONS FOR INDOOR AIR-QUALITY SAMPLING
    MALDONADO, EAB
    WOODS, JE
    [J]. BUILDING AND ENVIRONMENT, 1983, 18 (04) : 171 - 180
  • [5] The effect of air supply and air exhaust locations on particle restraint and removal in a laboratory utilizing a Lagrangian particle-tracking method
    Cheng, Shih-Feng
    Luo, Win-Jet
    Wu, Yu-Lieh
    Chung, Meng-Hua
    Huang, Yung-Shuen
    [J]. INTERNATIONAL JOURNAL OF THE PHYSICAL SCIENCES, 2010, 5 (14): : 2150 - 2160
  • [6] IMPROVING INDOOR AIR QUALITY USING LOCAL EXHAUST VENTILATION (LEV)
    Hussin, Norasikin Binti
    Ibrahim, Dzullijah Binti
    Ahmad, Farrah Noor Binti
    Yahya, Nur Hayati Binti Mohd
    Hashim, Siti Mardini Binti
    [J]. JURNAL TEKNOLOGI, 2015, 76 (06): : 7 - 11
  • [7] Evaluation of professional choice of sampling locations for indoor air quality assessment
    Hui, P. S.
    Wong, L. T.
    Mui, K. W.
    [J]. BUILDING AND ENVIRONMENT, 2007, 42 (08) : 2900 - 2907
  • [8] Exhaust ventilation in attached garages improves residential indoor air quality
    Mallach, G.
    St-Jean, M.
    MacNeill, M.
    Aubin, D.
    Wallace, L.
    Shin, T.
    Van Ryswyk, K.
    Kulka, R.
    You, H.
    Fugler, D.
    Lavigne, E.
    Wheeler, A. J.
    [J]. INDOOR AIR, 2017, 27 (02) : 487 - 499
  • [9] Effect of ventilation on indoor air quality
    Chen Jin-hua
    Duan Sheng-hui
    Zheng Ping
    Zhao Wen-jiang
    Zi Li-mei
    [J]. JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2007, 14 : 48 - 52
  • [10] Effect of wall construction materials over indoor air quality in humid and hot climate
    Nematchou, Modeste Kameni
    Tchinda, Rene
    Orosa, Jose A.
    Andreasi, Wagner Augusto
    [J]. JOURNAL OF BUILDING ENGINEERING, 2015, 3 : 16 - 23