Effects of inlet and exhaust locations and emitted gas density on indoor air contaminant concentrations

被引:60
|
作者
Khan, JA [1 ]
Feigley, CE
Lee, E
Ahmed, MR
Tamanna, S
机构
[1] Univ S Carolina, Dept Mech Engn, Columbia, SC 29208 USA
[2] Univ S Carolina, Dept Environm Hlth Sci, Columbia, SC 29208 USA
关键词
D O I
10.1016/j.buildenv.2005.04.002
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The steady-state distribution of contaminant concentrations in a workroom is a function of several factors, of which the types and relative position of air inlets and exhausts are some of the most important. Here several different inlet and exhaust locations and types (with or without diffuser) were investigated to determine the optimum inlet and exhaust positions. Room concentration patterns for a workroom were explored by computational fluid dynamics (CFD) simulations for various inlet locations, exhaust locations, contaminant gas densities, and dilution air flow rates. Average contaminant concentrations were calculated for the entire room, the breathing zone plane, and the near-source breathing zone (BZ). The computational results were validated with experimental results. For wall jet inlets and for lighter than air, the exhausts located near the ceiling resulted in lower concentrations than the corresponding exhausts near the floor. Also, the exhausts located on the same wall as the inlet were relatively better than that of the opposite side wall. The relative density of the contaminant was found to have some effects on the concentration distribution at low flow rates, whereas this effect was negligible at higher flow rates (8 ACH or higher). Exhaust location was not important for ceiling inlets as the room was well mixed. Although ceiling inlet type had almost no effect on average concentration, near-source concentrations were markedly less for the ceiling jet inlet than for the ceiling diffuser inlet. (c) 2005 Elsevier Ltd. All rights reserved.
引用
下载
收藏
页码:851 / 863
页数:13
相关论文
共 50 条
  • [1] Performance of deterministic workplace exposure assessment models for various contaminant source, air inlet, and exhaust locations
    Feigley, CE
    Bennett, JS
    Khan, J
    Lee, E
    AIHAJ, 2002, 63 (04): : 402 - 412
  • [2] Markov modeling of contaminant concentrations in indoor air
    Nicas, M
    AIHAJ, 2000, 61 (04): : 484 - 491
  • [3] Analysis of Gas Turbine Combustor Exhaust Emissions: Effects of Transient Inlet Air Pressure
    Tenango-Pirin, Oscar
    Espinosa, Sierra
    Garcia, Juan Carlos
    Rodriguez, Jose Alfredo
    ENERGY TECHNOLOGY, 2024, 12 (03)
  • [4] Effect of Wall Exhaust and Spill Locations on Indoor Air Quality in a Chemical Laboratory
    Morcos, Ayman A. Shaaban Samy M.
    Khalil, Essam E.
    Fouad, Mahmoud A.
    ASHRAE TRANSACTIONS 2014, VOL 120, PT 2, 2014, 120
  • [5] Fuzzy modeling and control of an engine air inlet with exhaust gas recirculation
    Bortolet, P
    Merlet, E
    Boverie, S
    CONTROL ENGINEERING PRACTICE, 1999, 7 (10) : 1269 - 1277
  • [6] Fuzzy modeling and control of an engine air inlet with exhaust gas recirculation
    Laboratoire LAAS/CNRS - 7, av. du Colonel Roche, 31077 Toulouse Cedex, France
    不详
    不详
    Control Eng. Pract., 10 (1269-1277):
  • [7] Fuzzy modeling and control of an engine air inlet with exhaust gas recirculation.
    Bortolet, P
    Merlet, E
    Boverie, S
    INTELLIGENT COMPONENTS FOR VEHICLES, 1998, : 71 - 77
  • [8] Investigation of Exhaust Gas Temperature Correction Methods for the Change of Air Inlet Temperature
    Zhao, Zhenning
    Wang, Jingjing
    Zhao, Zhenzhou
    Zhang, Qingfeng
    ADVANCED MATERIALS AND INFORMATION TECHNOLOGY PROCESSING II, 2012, 586 : 342 - +
  • [9] Development of a model to predict air contaminant concentrations following indoor spills of volatile liquids
    Reinke, PH
    Brosseau, LM
    ANNALS OF OCCUPATIONAL HYGIENE, 1997, 41 (04): : 415 - 435
  • [10] Relationship between radon concentrations in indoor air and in soil gas
    Vaupotic, J
    Andjelov, M
    Kobal, I
    ENVIRONMENTAL GEOLOGY, 2002, 42 (06): : 583 - 587