Effects of inlet and exhaust locations and emitted gas density on indoor air contaminant concentrations

被引:60
|
作者
Khan, JA [1 ]
Feigley, CE
Lee, E
Ahmed, MR
Tamanna, S
机构
[1] Univ S Carolina, Dept Mech Engn, Columbia, SC 29208 USA
[2] Univ S Carolina, Dept Environm Hlth Sci, Columbia, SC 29208 USA
关键词
D O I
10.1016/j.buildenv.2005.04.002
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The steady-state distribution of contaminant concentrations in a workroom is a function of several factors, of which the types and relative position of air inlets and exhausts are some of the most important. Here several different inlet and exhaust locations and types (with or without diffuser) were investigated to determine the optimum inlet and exhaust positions. Room concentration patterns for a workroom were explored by computational fluid dynamics (CFD) simulations for various inlet locations, exhaust locations, contaminant gas densities, and dilution air flow rates. Average contaminant concentrations were calculated for the entire room, the breathing zone plane, and the near-source breathing zone (BZ). The computational results were validated with experimental results. For wall jet inlets and for lighter than air, the exhausts located near the ceiling resulted in lower concentrations than the corresponding exhausts near the floor. Also, the exhausts located on the same wall as the inlet were relatively better than that of the opposite side wall. The relative density of the contaminant was found to have some effects on the concentration distribution at low flow rates, whereas this effect was negligible at higher flow rates (8 ACH or higher). Exhaust location was not important for ceiling inlets as the room was well mixed. Although ceiling inlet type had almost no effect on average concentration, near-source concentrations were markedly less for the ceiling jet inlet than for the ceiling diffuser inlet. (c) 2005 Elsevier Ltd. All rights reserved.
引用
下载
收藏
页码:851 / 863
页数:13
相关论文
共 50 条
  • [41] QUANTIFICATION OF AN INDOOR POPULATION BY MEANS OF AIR EXCHANGE-RATES AND CARBON-DIOXIDE GAS CONCENTRATIONS
    OLCERST, R
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1994, 55 (11): : 1080 - 1083
  • [42] Thermodynamic assessment of power requirements and impact of different gas-turbine inlet air cooling techniques at two different locations in Oman
    Dawoud, B
    Zurigat, YH
    Bortmany, J
    APPLIED THERMAL ENGINEERING, 2005, 25 (11-12) : 1579 - 1598
  • [43] Effects of fuel variation and inlet air temperature on combustion stability in a gas turbine model combustor
    Chen, Feier
    Ruan, Can
    Yu, Tao
    Cai, Weiwei
    Mao, Yebing
    Lu, Xingcai
    AEROSPACE SCIENCE AND TECHNOLOGY, 2019, 92 : 126 - 138
  • [44] EFFECTS OF INLET AIR HUMIDITY ON NOx AND CO EMISSIONS FROM A SMALL GAS TURBINE.
    Danjo, Kyokuo
    Sawada, Teruo
    1600, (34):
  • [45] MODELING THE EFFECTS OF EXHAUST VENTILATION ON RN-222 ENTRY RATES AND INDOOR RN-222 CONCENTRATIONS - REPLY
    MOWRIS, R
    FISK, W
    HEALTH PHYSICS, 1989, 57 (06): : 1035 - 1035
  • [46] Effects of temperature, inlet gas pressure and humidity on PEM water contents and current density distribution
    Hao, Huimin
    Mo, Rongjia
    Kang, Shuangyuan
    Wu, Zhifei
    RESULTS IN ENGINEERING, 2023, 20
  • [47] CFD analysis on characteristics of contaminated indoor air ventilation and its application in the evaluation of the effects of contaminant inhalation by a human occupant
    Hayashi, T
    Ishizu, Y
    Kato, S
    Murakami, S
    BUILDING AND ENVIRONMENT, 2002, 37 (03) : 219 - 230
  • [48] LIQUEFIED PETROLEUM GAS FOR ENGINES - EFFECTS OF INLET-AIR TEMPERATURE AND HUMIDITY ON PERFORMANCE OF AN LP-GAS ENGINE
    HARRIS, WL
    HUMMEL, JW
    SAE TRANSACTIONS, 1968, 76 : 71 - &
  • [49] A Study on the N2O Reduction Rate According to Temperature and Residence Time in the Exhaust Gas Atmosphere Emitted on Combustion of Air and Oxygen
    Yun, Jae Geun
    Kim, Ji Yeop
    Lee, Han Min
    Baik, Gwang Yeol
    Jeon, Min Kyu
    Yun, Jin Han
    Hong, Jung Goo
    ACS OMEGA, 2022, 7 (04): : 3434 - 3441
  • [50] An E-Nose-based indoor air quality monitoring system: prediction of combustible and toxic gas concentrations
    Mumyakmaz, Bekir
    Karabacak, Kerim
    TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES, 2015, 23 (03) : 729 - 740