eElectrochemical determination of chloramphenicol using a glassy carbon electrode modified with dendrite-like Fe3O4 nanoparticles

被引:36
|
作者
Giribabu, Krishnan [1 ]
Jang, Sung-Chan [1 ,2 ]
Haldorai, Yuvaraj [3 ]
Rethinasabapathy, Muruganantham [1 ]
Oh, Seo Yeong [1 ]
Rengaraj, Arunkumar [1 ]
Han, Young-Kyu [3 ]
Cho, Wan-Seob [4 ]
Roh, Changhyun [2 ,5 ]
Huh, Yun Suk [1 ]
机构
[1] Inha Univ, Dept Biol Engn, BSRC, Incheon 22212, South Korea
[2] KAERI, ARTI, Biotechnol Res Div, Jeongeup Si 56212, Jeonbuk, South Korea
[3] Dongguk Univ Seoul, Dept Energy & Mat Engn, Seoul 04620, South Korea
[4] Dong A Univ, Dept Med Biotechnol, Coll Hlth Sci, Lab Toxicol, Busan 49315, South Korea
[5] UST, Radiat Biotechnol & Appl Radioisotope Sci, Daejeon 34113, South Korea
基金
新加坡国家研究基金会;
关键词
magnetite nanoparticles; electrochemical deposition; chloramphenicol; sensor; square-wave voltammetry; MOLECULARLY IMPRINTED POLYMER; TANDEM MASS-SPECTROMETRY; LIQUID-CHROMATOGRAPHY; GOLD NANOPARTICLES; ELECTROCHEMICAL DETERMINATION; VOLTAMMETRIC DETERMINATION; GRAPHENE OXIDE; XPS ANALYSIS; MILK; RESIDUES;
D O I
10.5714/CL.2017.23.038
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this study, magnetite ((FeO4)-O-3) nanoparticles were electrochemically synthesized in an aqueous electrolyte at a given potential of -1.3 V for 180 s. Scanning electron microscopy revealed that dendrite-like Fe3O4 nanoparticles with a mean size of < 80 nm were electro-deposited on a glassy carbon electrode (GCE). The Fe3O4/GCE was utilized for sensing chloramphenicol (CAP) by cyclic voltammetry and square wave voltammetry. A reduction peak of CAP at the Fe3O4/GCE was observed at 0.62 V, whereas the uncoated GCE exhibited a very small response compared to that of the Fe3O4/GCE. The electrocatalytic ability of Fe3O4 was mainly attributed to the formation of Fe(VI) during the anodic scan, and its reduction to Fe(III) on the cathodic scan facilitated the sensing of CAP. The effects of pH and scan rate were measured to determine the optimum conditions at which the Fe3O4/GCE exhibited the highest sensitivity with a lower detection limit. The reduction current for CAP was proportional to its concentration under optimized conditions in a range of 0.09-47 mu M with a correlation coefficient of 0.9919 and a limit of detection of 0.09 mu M (S/N=3). Moreover, the fabricated sensor exhibited anti-interference ability towards 4-nitrophenol, thiamphenicol, and 4-nitrobenzamide. The developed electrochemical sensor is a cost effective, reliable, and straightforward approach for the electrochemical determination of CAP in real time applications.
引用
收藏
页码:38 / 47
页数:10
相关论文
共 50 条
  • [31] Adsorptive anodic stripping differential pulse voltammetric determination of CellCept at Fe3O4 nanoparticles decorated multi-walled carbon nanotubes modified glassy carbon electrode
    Gholivand, Mohammad Bagher
    Solgi, Mohammad
    [J]. ANALYTICAL BIOCHEMISTRY, 2017, 520 : 1 - 8
  • [32] Electrochemical determination of clonazepam drug based on glassy carbon electrode modified with Fe3O4/R-SH/Pd nanocomposite
    Lotfi, Shahram
    Veisi, Hojat
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2019, 103
  • [33] Electrochemical determination of citalopram on new Schiff base functionalized magnetic Fe3O4 nanoparticle/MWCNTs modified glassy carbon electrode
    Keypour, Hassan
    Saremi, Shokoufeh Ghahri
    Veisi, Hojat
    Noroozi, Mohammad
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 780 : 160 - 168
  • [34] Electrochemical detection of choline at f-MWCNT/Fe3O4 nanocomposite modified glassy carbon electrode
    Uwaya, Gloria E.
    Fayemi, Omolola E.
    [J]. MATERIALS RESEARCH EXPRESS, 2021, 8 (05)
  • [35] An ultra-sensitive rifampicin electrochemical sensor based on Fe3O4 nanoparticles anchored Multiwalled Carbon nanotube modified glassy carbon electrode
    Alizadeh, Marzie
    Asrami, Padideh Naderi
    Altuner, Elif Esra
    Gulbagca, Fulya
    Tiri, Rima Nour Elhouda
    Aygun, Aysenur
    Sen, Fatih
    Cheraghi, Somaye
    Kaynak, Idris
    [J]. CHEMOSPHERE, 2022, 309
  • [36] Electrochemical Determination of 17-β-Estradiol Using a Glassy Carbon Electrode Modified with α-Fe2O3 Nanoparticles Supported on Carbon Nanotubes
    Galvao, Juliana Costa Rolim
    Araujo, Mayara da Silva
    Prete, Maiyara Carolyne
    Neto, Vanildo Leao
    Dall'Antonia, Luiz Henrique
    Matos, Roberto
    Tarley, Cesar Ricardo Texeira
    Medeiros, Roberta Antigo
    [J]. MOLECULES, 2023, 28 (17):
  • [37] Fabrication of an electrochemical biosensor based on Fe3O4 nanoparticles and uricase modified carbon paste electrode for uric acid determination
    Zehra Ozden Erdogan
    Semahat Kucukkolbası
    [J]. Monatshefte für Chemie - Chemical Monthly, 2021, 152 : 309 - 314
  • [38] Fabrication of an electrochemical biosensor based on Fe3O4 nanoparticles and uricase modified carbon paste electrode for uric acid determination
    Erdogan, Zehra Ozden
    Kucukkolbasi, Semahat
    [J]. MONATSHEFTE FUR CHEMIE, 2021, 152 (03): : 309 - 314
  • [39] Highly sensitive determination of nitrite using a carbon ionic liquid electrode modified with Fe3O4 magnetic nanoparticle
    Absalan, Ghodratollah
    Akhond, Morteza
    Bananejad, Asma
    Ershadifar, Hamid
    [J]. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2015, 12 (07) : 1293 - 1301
  • [40] Highly sensitive determination of nitrite using a carbon ionic liquid electrode modified with Fe3O4 magnetic nanoparticle
    Ghodratollah Absalan
    Morteza Akhond
    Asma Bananejad
    Hamid Ershadifar
    [J]. Journal of the Iranian Chemical Society, 2015, 12 : 1293 - 1301