eElectrochemical determination of chloramphenicol using a glassy carbon electrode modified with dendrite-like Fe3O4 nanoparticles

被引:36
|
作者
Giribabu, Krishnan [1 ]
Jang, Sung-Chan [1 ,2 ]
Haldorai, Yuvaraj [3 ]
Rethinasabapathy, Muruganantham [1 ]
Oh, Seo Yeong [1 ]
Rengaraj, Arunkumar [1 ]
Han, Young-Kyu [3 ]
Cho, Wan-Seob [4 ]
Roh, Changhyun [2 ,5 ]
Huh, Yun Suk [1 ]
机构
[1] Inha Univ, Dept Biol Engn, BSRC, Incheon 22212, South Korea
[2] KAERI, ARTI, Biotechnol Res Div, Jeongeup Si 56212, Jeonbuk, South Korea
[3] Dongguk Univ Seoul, Dept Energy & Mat Engn, Seoul 04620, South Korea
[4] Dong A Univ, Dept Med Biotechnol, Coll Hlth Sci, Lab Toxicol, Busan 49315, South Korea
[5] UST, Radiat Biotechnol & Appl Radioisotope Sci, Daejeon 34113, South Korea
基金
新加坡国家研究基金会;
关键词
magnetite nanoparticles; electrochemical deposition; chloramphenicol; sensor; square-wave voltammetry; MOLECULARLY IMPRINTED POLYMER; TANDEM MASS-SPECTROMETRY; LIQUID-CHROMATOGRAPHY; GOLD NANOPARTICLES; ELECTROCHEMICAL DETERMINATION; VOLTAMMETRIC DETERMINATION; GRAPHENE OXIDE; XPS ANALYSIS; MILK; RESIDUES;
D O I
10.5714/CL.2017.23.038
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this study, magnetite ((FeO4)-O-3) nanoparticles were electrochemically synthesized in an aqueous electrolyte at a given potential of -1.3 V for 180 s. Scanning electron microscopy revealed that dendrite-like Fe3O4 nanoparticles with a mean size of < 80 nm were electro-deposited on a glassy carbon electrode (GCE). The Fe3O4/GCE was utilized for sensing chloramphenicol (CAP) by cyclic voltammetry and square wave voltammetry. A reduction peak of CAP at the Fe3O4/GCE was observed at 0.62 V, whereas the uncoated GCE exhibited a very small response compared to that of the Fe3O4/GCE. The electrocatalytic ability of Fe3O4 was mainly attributed to the formation of Fe(VI) during the anodic scan, and its reduction to Fe(III) on the cathodic scan facilitated the sensing of CAP. The effects of pH and scan rate were measured to determine the optimum conditions at which the Fe3O4/GCE exhibited the highest sensitivity with a lower detection limit. The reduction current for CAP was proportional to its concentration under optimized conditions in a range of 0.09-47 mu M with a correlation coefficient of 0.9919 and a limit of detection of 0.09 mu M (S/N=3). Moreover, the fabricated sensor exhibited anti-interference ability towards 4-nitrophenol, thiamphenicol, and 4-nitrobenzamide. The developed electrochemical sensor is a cost effective, reliable, and straightforward approach for the electrochemical determination of CAP in real time applications.
引用
收藏
页码:38 / 47
页数:10
相关论文
共 50 条
  • [21] Electrochemical Detection of Nitrofuranzone and its Metabolite Using Glassy Carbon Electrode Modified by Fe3O4 Functionalized Graphene
    He, Baoshan
    Du, Gengan
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (10): : 8546 - 8560
  • [22] Electrochemical determination of NADH using a glassy carbon electrode modified with Fe3O4 nanoparticles and poly-2,6-pyridinedicarboxylic acid, and its application to the determination of antioxidant capacity
    Cui, Lin
    Ai, Shiyun
    Shang, Kun
    Meng, Xiaomeng
    Wang, Chengcheng
    [J]. MICROCHIMICA ACTA, 2011, 174 (1-2) : 31 - 39
  • [23] Electrochemical determination of NADH using a glassy carbon electrode modified with Fe3O4 nanoparticles and poly-2,6-pyridinedicarboxylic acid, and its application to the determination of antioxidant capacity
    Lin Cui
    Shiyun Ai
    Kun Shang
    Xiaomeng Meng
    Chengcheng Wang
    [J]. Microchimica Acta, 2011, 174 : 31 - 39
  • [24] Enhanced oxygen evolution reaction over glassy carbon electrode modified with NiOx and Fe3O4
    Tammam, Reham Helmy
    Fekry, Amany Mohamed
    Saleh, Mahmoud Mohamed
    [J]. KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2019, 36 (11) : 1932 - 1939
  • [25] Enhanced oxygen evolution reaction over glassy carbon electrode modified with NiOx and Fe3O4
    Reham Helmy Tammam
    Amany Mohamed Fekry
    Mahmoud Mohamed Saleh
    [J]. Korean Journal of Chemical Engineering, 2019, 36 : 1932 - 1939
  • [26] An electrochemical sensor for rizatriptan benzoate determination using Fe3O4 nanoparticle/multiwall carbon nanotube-modified glassy carbon electrode in real samples
    Madrakian, Tayyebeh
    Maleki, Somayeh
    Heidari, Mozhgan
    Afkhami, Abbas
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 63 : 637 - 643
  • [27] Electrochemical Sensor for Determination of Various Phenolic Compounds in Wine Samples Using Fe3O4 Nanoparticles Modified Carbon Paste Electrode
    Pwavodi, Pwadubashiyi C.
    Ozyurt, Vasfiye H.
    Asir, Suleyman
    Ozsoz, Mehmet
    [J]. MICROMACHINES, 2021, 12 (03)
  • [28] Electrooxidation behavior of warfarin in Fe3O4 nanoparticles modified carbon paste electrode and its determination in real samples
    Gholivand, Mohammad Bagher
    Torkashvand, Maryam
    Yavari, Eilnaz
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 48 : 235 - 242
  • [29] Electrocatalysis and sensitive determination of Sudan I at Fe3O4/graphene modified glassy carbon electrodes
    Luo, Suxing
    Wu, Yuanhui
    Gou, Hua
    [J]. FRONTIERS OF MANUFACTURING SCIENCE AND MEASURING TECHNOLOGY III, PTS 1-3, 2013, 401 : 775 - 778
  • [30] Selective detection toward Cd2+ using Fe3O4/RGO nanoparticle modified glassy carbon electrode
    Sun, Yu-Feng
    Chen, Wen-Kai
    Li, Wen-Juan
    Jiang, Tian-Jia
    Liu, Jin-Huai
    Liu, Zhong-Gang
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 714 : 97 - 102