Impedance controller and its clinical use of the remote ultrasound diagnostic system

被引:0
|
作者
Koizumi, N [1 ]
Warisawa, S [1 ]
Hashizume, H [1 ]
Mitsuishi, M [1 ]
机构
[1] Univ Tokyo, Grad Sch Engn, Dept Engn Synth, Tokyo 1138656, Japan
关键词
D O I
暂无
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
A master-slave type remote ultrasound diagnostic system was developed. This paper presents and evaluates its control strategy. There is only one impedance controller that is located in the master site or the slave site or the relay point in the conventional impedance controller. Therefore, the effect of the time lag in transmitting force and position data becomes large in the conventional system. Then we propose an impedance controller to cope with this problem. In the proposed system, the position controller for the slave manipulator is also constructed by means of a velocity-control-based impedance controller. This feature makes it possible to shorten the dead time taken by the slave manipulator to respond for the contact force input. This paper also reports the result of a clinical use of the remote ultrasound diagnostic system. The result of the experiments demonstrates that a medical doctor can diagnose patients as well as the conventional diagnosis.
引用
收藏
页码:676 / 683
页数:8
相关论文
共 50 条
  • [1] Impedance controller for a remote ultrasound diagnostic system
    Koizumi, N
    Warisawa, S
    Mitsuishi, M
    Hashizume, H
    2002 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS I-IV, PROCEEDINGS, 2002, : 651 - 656
  • [2] Continuous path controller for the remote ultrasound diagnostic system
    Koizumi, Norihiro
    Warisawa, Shin'ichi
    Hashizume, Hiroyuki
    Mitsuishi, Mamoru
    IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2008, 13 (02) : 206 - 218
  • [3] Continuous path controller of slave manipulator in remote ultrasound diagnostic system
    Koizumi, N
    Warisawa, S
    Mitsuishi, M
    Hashizume, H
    2002 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS I-IV, PROCEEDINGS, 2002, : 3368 - 3373
  • [4] Manipulability enhancement by an impedance parameter tuning for a remote ultrasound diagnostic system
    Koizumi, N
    Kato, T
    Warisawa, S
    Hashizume, H
    Mitsuishi, M
    EXPERIMENTAL ROBOTICS VIII, 2003, 5 : 527 - 537
  • [5] Remote ultrasound diagnostic system
    Mitsuishi, M
    Warisawa, S
    Tsuda, T
    Higuchi, T
    Koizumi, N
    Hashizume, H
    Fujiwara, K
    2001 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS I-IV, PROCEEDINGS, 2001, : 1567 - 1574
  • [6] Remote Ultrasound Diagnostic System (RUDS)
    Koizumi, Norihiro
    Tsurumi, Takehiko
    Kato, Takahiro
    Warisawa, Shin'ichi
    Nagoshi, Mitsuru
    Hashizume, Hiroyuki
    Mitsuishi, Mamoru
    JOURNAL OF ROBOTICS AND MECHATRONICS, 2014, 26 (03) : 396 - 397
  • [7] Construction Methodology for a Remote Ultrasound Diagnostic System
    Koizumi, Norihiro
    Warisawa, Shin'ichi
    Nagoshi, Mitsuru
    Hashizume, Hiroyuki
    Mitsuishi, Mamoru
    IEEE TRANSACTIONS ON ROBOTICS, 2009, 25 (03) : 522 - 538
  • [8] DIAGNOSTIC ULTRASOUND - ITS USE IN THE EVALUATION OF MUSCLE
    HICKS, JE
    SHAWKER, TH
    JONES, BL
    LINZER, M
    GERBER, LH
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1984, 65 (03): : 129 - 131
  • [9] Automatic control switching according to diagnostic tasks for a remote ultrasound diagnostic system
    Mitsuishi, Mamoru
    Hashizume, Hiroyuki
    2006 1ST IEEE RAS-EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL ROBOTICS AND BIOMECHATRONICS, VOLS 1-3, 2006, : 1064 - +
  • [10] The Improvement of Telerobotic System Behavior in Contact with Remote Environment by Extension of an Impedance Controller
    Velagic, J.
    Huseinbegovic, S.
    Osmic, N.
    INTERNATIONAL JOURNAL OF ONLINE ENGINEERING, 2008, 4 (04) : 39 - 44