Continuous path controller for the remote ultrasound diagnostic system

被引:18
|
作者
Koizumi, Norihiro [1 ]
Warisawa, Shin'ichi [1 ]
Hashizume, Hiroyuki [2 ]
Mitsuishi, Mamoru [1 ]
机构
[1] Univ Tokyo, Grad Sch Engn, Tokyo 1138656, Japan
[2] Kasaoka Daiichi Hosp, Kasaoka 7140043, Japan
关键词
continuous path (CP) control; impedance control; master-slave manipulation; remote medical system; remote ultrasound diagnostic system;
D O I
10.1109/TMECH.2008.918530
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A master-slave type remote ultrasound diagnostic system has been developed. The impedance controller has; been implemented and reported for the positions of the master and slave manipulators to display and control the contact force between the ultrasound probe and the affected area. The present paper introduces an alternative orientation controller utilizing continuous path (CP) control in the remote ultrasound diagnostic system. The major contribution of the present paper is an introduction to the, velocity-control-based CP controller for the master-slave type remote medical system, which realizes the continuous motion of the slave manipulator without a reduction in the master motion tracking performance. It is difficult to communicate information for control at high sampling rates between the master and slave site because the communication network between the master and slave site (local area network, integrated services digital network, asymmetric digital subscriber line, etc.) is. limited. To cope with this problem, the CP controller was introduced to the orientation controller in special remote medical systems. The CP control realizes the continuous motion of the slave manipulator under the limited sampling rate of the orientation data transmitted by the master manipulator and high master motion tracking performance of the slave manipulator. This allows the slave manipulator safety to be improved and decreases the volume of the transmitted data. The experimental results demonstrate the accuracy of the path control of the slave manipulator using the CP control in the master-slave manipulation system, compared with the conventional point-to-point control.
引用
收藏
页码:206 / 218
页数:13
相关论文
共 50 条
  • [1] Continuous path controller of slave manipulator in remote ultrasound diagnostic system
    Koizumi, N
    Warisawa, S
    Mitsuishi, M
    Hashizume, H
    2002 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS I-IV, PROCEEDINGS, 2002, : 3368 - 3373
  • [2] Impedance controller for a remote ultrasound diagnostic system
    Koizumi, N
    Warisawa, S
    Mitsuishi, M
    Hashizume, H
    2002 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS I-IV, PROCEEDINGS, 2002, : 651 - 656
  • [3] Impedance controller and its clinical use of the remote ultrasound diagnostic system
    Koizumi, N
    Warisawa, S
    Hashizume, H
    Mitsuishi, M
    2003 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1-3, PROCEEDINGS, 2003, : 676 - 683
  • [4] Remote ultrasound diagnostic system
    Mitsuishi, M
    Warisawa, S
    Tsuda, T
    Higuchi, T
    Koizumi, N
    Hashizume, H
    Fujiwara, K
    2001 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS I-IV, PROCEEDINGS, 2001, : 1567 - 1574
  • [5] Remote Ultrasound Diagnostic System (RUDS)
    Koizumi, Norihiro
    Tsurumi, Takehiko
    Kato, Takahiro
    Warisawa, Shin'ichi
    Nagoshi, Mitsuru
    Hashizume, Hiroyuki
    Mitsuishi, Mamoru
    JOURNAL OF ROBOTICS AND MECHATRONICS, 2014, 26 (03) : 396 - 397
  • [6] Construction Methodology for a Remote Ultrasound Diagnostic System
    Koizumi, Norihiro
    Warisawa, Shin'ichi
    Nagoshi, Mitsuru
    Hashizume, Hiroyuki
    Mitsuishi, Mamoru
    IEEE TRANSACTIONS ON ROBOTICS, 2009, 25 (03) : 522 - 538
  • [7] Automatic control switching according to diagnostic tasks for a remote ultrasound diagnostic system
    Mitsuishi, Mamoru
    Hashizume, Hiroyuki
    2006 1ST IEEE RAS-EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL ROBOTICS AND BIOMECHATRONICS, VOLS 1-3, 2006, : 1064 - +
  • [8] Decomposing and reconstructing required functions to construct the remote ultrasound diagnostic system
    Koizumi, Norihiro
    Warisawa, Shin'ichi
    Mitsuishi, Mamoru
    Hashizume, Hiroyuki
    2006 IEEE CONFERENCE ON ROBOTICS, AUTOMATION AND MECHATRONICS, VOLS 1 AND 2, 2006, : 440 - +
  • [9] Manipulability enhancement by an impedance parameter tuning for a remote ultrasound diagnostic system
    Koizumi, N
    Kato, T
    Warisawa, S
    Hashizume, H
    Mitsuishi, M
    EXPERIMENTAL ROBOTICS VIII, 2003, 5 : 527 - 537
  • [10] A novel hand-controller for remote ultrasound imaging
    Najafi, Farshid
    Sepehri, Nariman
    MECHATRONICS, 2008, 18 (10) : 578 - 590