Impedance controller and its clinical use of the remote ultrasound diagnostic system

被引:0
|
作者
Koizumi, N [1 ]
Warisawa, S [1 ]
Hashizume, H [1 ]
Mitsuishi, M [1 ]
机构
[1] Univ Tokyo, Grad Sch Engn, Dept Engn Synth, Tokyo 1138656, Japan
关键词
D O I
暂无
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
A master-slave type remote ultrasound diagnostic system was developed. This paper presents and evaluates its control strategy. There is only one impedance controller that is located in the master site or the slave site or the relay point in the conventional impedance controller. Therefore, the effect of the time lag in transmitting force and position data becomes large in the conventional system. Then we propose an impedance controller to cope with this problem. In the proposed system, the position controller for the slave manipulator is also constructed by means of a velocity-control-based impedance controller. This feature makes it possible to shorten the dead time taken by the slave manipulator to respond for the contact force input. This paper also reports the result of a clinical use of the remote ultrasound diagnostic system. The result of the experiments demonstrates that a medical doctor can diagnose patients as well as the conventional diagnosis.
引用
收藏
页码:676 / 683
页数:8
相关论文
共 50 条
  • [31] DIAGNOSTIC ULTRASOUND IN CLINICAL MEDICINE
    HOLDER, JC
    TEXAS REPORTS ON BIOLOGY AND MEDICINE, 1975, 33 (02) : 326 - 327
  • [32] THE PRUDENT USE OF DIAGNOSTIC ULTRASOUND
    WELLS, PNT
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1987, 13 (07): : 391 - 400
  • [33] Clinical perspective of diagnostic ultrasound
    Meilstrup, JF
    MEDICAL IMAGING 1999: ULTRASONIC TRANSDUCER ENGINEERING, 1999, 3664 : 2 - 6
  • [34] CLINICAL APPLICATIONS OF DIAGNOSTIC ULTRASOUND
    TERRY, HJ
    BIOMEDICAL ENGINEERING, 1973, 8 (02) : 71 - 72
  • [35] Use of a multiaxial diagnostic system in clinical genetics - Reply
    Robin, NH
    Biesecker, LG
    GENETICS IN MEDICINE, 2002, 4 (02) : 96 - 96
  • [36] Remote monitoring and diagnostic system
    Diesel & Gas Turbine Worldwide, 2000, 32 (03):
  • [37] Surgeon-performed ultrasound - Its use in clinical practice
    Rozycki, GS
    ANNALS OF SURGERY, 1998, 228 (01) : 16 - 28
  • [38] Use of a Remote Computerized System for Study Documentation in Clinical Trials
    Mark S. Jones
    Dennis W. Raisch
    David Garnand
    Mike R. Sather
    Drug information journal : DIJ / Drug Information Association, 1998, 32 (4): : 1153 - 1163
  • [39] Use of a remote computerized system for study documentation in clinical trials
    Jones, MS
    Raisch, DW
    Garnand, D
    Sather, MR
    DRUG INFORMATION JOURNAL, 1998, 32 (04): : 1153 - 1163
  • [40] SPATIAL RESOLUTION AND MEASUREMENT ACCURACY OF THE ULTRASOUND DIAGNOSTIC SYSTEM AT ACOUSTIC REMOTE PALPATION USING HIGH INTENSITY FOCUSING ULTRASOUND
    Barannik, Evgen A.
    Pupchenko, Viktor, I
    Marusenko, Anatoliy, I
    Knyazyev, Olexiy, V
    Tsybin, Igor M.
    Berkovich, Aleksandr E.
    EAST EUROPEAN JOURNAL OF PHYSICS, 2019, (04): : 82 - 90