Optimization of exposure parameters in full field digital mammography

被引:71
|
作者
Williams, Mark B. [1 ]
Raghunathan, Priya [1 ]
More, Mitali J. [1 ]
Seibert, J. Anthony [2 ]
Kwan, Alexander [2 ]
Lo, Joseph Y. [3 ]
Samei, Ehsan [3 ]
Ranger, Nicole T. [3 ]
Fajardo, Laurie L. [4 ]
McGruder, Allen [4 ]
McGruder, Sandra M. [4 ]
Maidment, Andrew D. A. [5 ]
Yaffe, Martin J. [6 ]
Bloomquist, Aili [6 ]
Mawdsley, Gordon E. [6 ]
机构
[1] Univ Virginia, Charlottesville, VA 22908 USA
[2] Univ Calif Davis, Sacramento, CA 95817 USA
[3] Duke Univ, Durham, NC 27705 USA
[4] Univ Iowa, Iowa City, IA 52242 USA
[5] Univ Penn, Philadelphia, PA 19104 USA
[6] Sunnybrook Hlth Sci Ctr, Toronto, ON M4N 3M5, Canada
关键词
digital mammography; exposure parameters; technique factors; beam optimization;
D O I
10.1118/1.2912177
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Optimization of exposure parameters (target, filter, and kVp) in digital mammography necessitates maximization of the image signal-to-noise ratio (SNR), while simultaneously minimizing patient dose. The goal of this study is to compare, for each of the major commercially available full field digital mammography (FFDM) systems, the impact of the selection of technique factors on image SNR and radiation dose for a range of breast thickness and tissue types. This phantom study is an update of a previous investigation and includes measurements on recent versions of two of the FFDM systems discussed in that article, as well as on three FFDM systems not available at that time. The five commercial FFDM systems tested, the Senographe 2000D from GE Healthcare, the Mammomat Novation DR from Siemens, the Selenia from Hologic, the Fischer Senoscan, and Fuji's 5000MA used with a Lorad M-IV mammography unit, are located at five different university test sites. Performance was assessed using all available x-ray target and filter combinations and nine different phantom types (three compressed thicknesses and three tissue composition types). Each phantom type was also imaged using the automatic exposure control (AEC) of each system to identify the exposure parameters used under automated image acquisition. The figure of merit (FOM) used to compare technique factors is the ratio of the square of the image SNR to the mean glandular dose. The results show that, for a given target/filter combination, in general FOM is a slowly changing function of kVp, with stronger dependence on the choice of target/filter combination. In all cases the FOM was a decreasing function of kVp at the top of the available range of kVp settings, indicating that higher tube voltages would produce no further performance improvement. For a given phantom type, the exposure parameter set resulting in the highest FOM value was system specific, depending on both the set of available target/filter combinations, and on the receptor type. In most cases, the AECs of the FFDM systems successfully identified exposure parameters resulting in FOM values near the maximum ones, however, there were several examples where AEC performance could be improved. (C) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:2414 / 2423
页数:10
相关论文
共 50 条
  • [1] Optimization of Exposure Parameters in Full Field Digital Mammography using Figure of Merit
    Elias, Laila Suryani
    Lin, Eng May
    Chin, Ang Wee
    Tajuddin, Abd Aziz
    Arasaratnam, Shantini A.
    Aziz, Suraya
    Osman, Khairul
    Chelliah, Kanaga Kumari
    SAINS MALAYSIANA, 2010, 39 (02): : 299 - 303
  • [2] Digital Mammography Versus Full-Field Digital Mammography
    Hall, Ferris M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (01) : 240 - 240
  • [3] Lesion-specific exposure parameters for breast cancer diagnosis on digital breast tomosynthesis and full-field digital mammography
    Ma, Le
    Liu, Hui
    Lin, Xiaojia
    Cai, Yuxing
    Zhang, Ling
    Chen, Weiguo
    Qin, Genggeng
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2022, 77
  • [4] Full-field digital mammography
    Bick, U
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (12): : 957 - 964
  • [5] Full field digital mammography scanner
    Tesic, MM
    Piccaro, MF
    Munier, B
    EUROPEAN JOURNAL OF RADIOLOGY, 1999, 31 (01) : 2 - 17
  • [6] Full-field digital mammography
    U Bick
    Breast Cancer Research, 2 (Suppl 2)
  • [7] Benefits of full field digital mammography
    Mundt, Y
    PROCEEDINGS OF THE 23RD INTERNATIONAL CONGRESS OF RADIOLOGY OF THE INTERNATIONAL SOCIETY OF RADIOLOGY, 2004, : 295 - 297
  • [8] Development of full field digital mammography
    Yaffe, MJ
    DIGITAL MAMMOGRAPHY, 1998, 13 : 3 - 10
  • [9] Evaluation of the exposure dose reduction in full-field digital mammography system
    Tanigoshi, M
    Kobayashi, H
    Uchiyama, N
    Suzuki, T
    Kumazaki, T
    DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2003, : 149 - 151
  • [10] Automatic exposure control for a slot scanning full field digital mammography system
    Elbakri, DA
    Lakshminarayanan, AV
    Tesic, MM
    MEDICAL PHYSICS, 2005, 32 (09) : 2763 - 2770