MRI quantification of non-Gaussian water diffusion in normal human kidney: a diffusional kurtosis imaging study

被引:71
|
作者
Huang, Yanqi [1 ,2 ]
Chen, Xin [1 ,2 ]
Zhang, Zhongping [3 ]
Yan, Lifen [1 ]
Pan, Dan [1 ,2 ]
Liang, Changhong [1 ]
Liu, Zaiyi [1 ]
机构
[1] Guangdong Acad Med Sci, Guangdong Gen Hosp, Dept Radiol, Guangzhou 510080, Guangdong, Peoples R China
[2] Southern Med Univ, Grad Coll, Guangzhou, Guangdong, Peoples R China
[3] GE Healthcare China, Guangzhou, Guangdong, Peoples R China
关键词
diffusional kurtosis imaging; non-Gaussian diffusion; diffusion tensor imaging; human kidney; INTRAVOXEL INCOHERENT MOTION; WEIGHTED MRI; WHITE-MATTER; REPEATABILITY; REGISTRATION; COEFFICIENT; PARAMETERS; ANISOTROPY; HYDRATION; TENSORS;
D O I
10.1002/nbm.3235
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Our aim was to prospectively evaluate the feasibility of diffusional kurtosis imaging (DKI) in normal human kidney and to report preliminary DKI measurements. Institutional review board approval and informed consent were obtained. Forty-two healthy volunteers underwent diffusion-weighted imaging (DWI) scans with a 3-T MR scanner. b values of 0, 500 and 1000s/mm(2) were adopted. Maps of fractional anisotropy (FA), mean diffusivity (MD), radial diffusivity (D-perpendicular to), axial diffusivity (D-||), mean kurtosis (MK), radial kurtosis (K-perpendicular to) and axial kurtosis (K-||) were produced. Three representative axial slices in the upper pole, mid-zone and lower pole were selected in the left and right kidney. On each selected slice, three regions of interest were drawn on the renal cortex and another three on the medulla. Statistical comparison was performed with t-test and analysis of variance. Thirty-seven volunteers successfully completed the scans. No statistically significant differences were observed between the left and right kidney for all metrics (p values in the cortex: FA, 0.114; MD, 0.531; D-perpendicular to, 0.576; D-||, 0.691; MK, 0.934; K-perpendicular to, 0.722; K-||, 0.891; p values in the medulla: FA, 0.348; MD, 0.732; D-perpendicular to, 0.470; D-||, 0.289; MK, 0.959; K-perpendicular to, 0.780; K-||, 0.287). Kurtosis metrics (MK, K-||, K-perpendicular to) obtained in the renal medulla were significantly (p <0.001) higher than those in the cortex (0.552 +/- 0.04, 0.637 +/- 0.07 and 0.530 +/- 0.08 in the medulla and 0.373 +/- 0.04, 0.492 +/- 0.06 and 0.295 +/- 0.06 in the cortex, respectively). For the diffusivity measures, FA of the medulla (0.356 +/- 0.03) was higher than that of the cortex (0.179 +/- 0.03), whereas MD, D-perpendicular to and D-|| (mm(2)/ms) were lower in the medulla than in the cortex (3.88 +/- 0.09, 3.50 +/- 0.23 and 4.65 +/- 0.29 in the cortex and 2.88 +/- 0.11, 2.32 +/- 0.20 and 3.47 +/- 0.31 in the medulla, respectively). Our results indicate that DKI is feasible in the human kidney. We have reported the preliminary DKI measurements of normal human kidney that demonstrate well the non-Gaussian behavior of water diffusion, especially in the renal medulla. Copyright (c) 2014 John Wiley & Sons, Ltd.
引用
收藏
页码:154 / 161
页数:8
相关论文
共 50 条
  • [41] A preliminary diffusional kurtosis imaging study of Parkinson disease: comparison with conventional diffusion tensor imaging
    Kamagata, Koji
    Tomiyama, Hiroyuki
    Hatano, Taku
    Motoi, Yumiko
    Abe, Osamu
    Shimoji, Keigo
    Kamiya, Kouhei
    Suzuki, Michimasa
    Hori, Masaaki
    Yoshida, Mariko
    Hattori, Nobutaka
    Aoki, Shigeki
    NEURORADIOLOGY, 2014, 56 (03) : 251 - 258
  • [42] Dynamics in Crowded Environments: Is Non-Gaussian Brownian Diffusion Normal?
    Kwon, Gyemin
    Sung, Bong June
    Yethiraj, Arun
    JOURNAL OF PHYSICAL CHEMISTRY B, 2014, 118 (28): : 8128 - 8134
  • [43] Non-Gaussian diffusion imaging for malignant and benign pulmonary nodule differentiation: a preliminary study
    Das, Sushant Kumar
    Yang, Dong Jun
    Wang, Jin Liang
    Zhang, Chuan
    Yang, Han Feng
    ACTA RADIOLOGICA, 2017, 58 (01) : 19 - 26
  • [44] Diffusion MRI in Peripheral Nerves: Optimized b Values and the Role of Non-Gaussian Diffusion
    Foesleitner, Olivia
    Sulaj, Alba
    Sturm, Volker
    Kronlage, Moritz
    Godel, Tim
    Preisner, Fabian
    Nawroth, Peter Paul
    Bendszus, Martin
    Heiland, Sabine
    Schwarz, Daniel
    RADIOLOGY, 2022, 302 (01) : 153 - 161
  • [45] Mapping the Orientation of White Matter Fiber Bundles: A Comparative Study of Diffusion Tensor Imaging, Diffusional Kurtosis Imaging, and Diffusion Spectrum Imaging
    Glenn, G. R.
    Kuo, L. -W.
    Chao, Y. -P.
    Lee, C. -Y.
    Helpern, J. A.
    Jensen, J. H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (07) : 1216 - 1222
  • [46] Generalized diffusion tensor imaging (GDTI): A method for characterizing and imaging diffusion anisotropy caused by non-Gaussian diffusion
    Liu, CL
    Bammer, R
    Moseley, ME
    ISRAEL JOURNAL OF CHEMISTRY, 2003, 43 (1-2) : 145 - 154
  • [47] Quantification of normal-appearing white matter tract integrity in multiple sclerosis: a diffusion kurtosis imaging study
    de Kouchkovsky, Ivan
    Fieremans, Els
    Fleysher, Lazar
    Herbert, Joseph
    Grossman, Robert I.
    Inglese, Matilde
    JOURNAL OF NEUROLOGY, 2016, 263 (06) : 1146 - 1155
  • [48] Quantification of normal-appearing white matter tract integrity in multiple sclerosis: a diffusion kurtosis imaging study
    Ivan de Kouchkovsky
    Els Fieremans
    Lazar Fleysher
    Joseph Herbert
    Robert I. Grossman
    Matilde Inglese
    Journal of Neurology, 2016, 263 : 1146 - 1155
  • [49] Non-gaussian diffusion MRI allows early characterization of tissue disruption in PPMS
    Petracca, M.
    Saiote, C.
    Fleysher, L.
    Fabian, M.
    Howard, J.
    Farrell, C.
    Miller, A.
    Lublin, F.
    Inglese, M.
    MULTIPLE SCLEROSIS JOURNAL, 2016, 22 : 508 - 508
  • [50] Detecting compartmental non-Gaussian diffusion with symmetrized double-PFG MRI
    Paulsen, Jeffrey L.
    Ozarslan, Evren
    Komlosh, Michal E.
    Basser, Peter J.
    Song, Yi-Qiao
    NMR IN BIOMEDICINE, 2015, 28 (11) : 1550 - 1556