MRI quantification of non-Gaussian water diffusion in normal human kidney: a diffusional kurtosis imaging study

被引:71
|
作者
Huang, Yanqi [1 ,2 ]
Chen, Xin [1 ,2 ]
Zhang, Zhongping [3 ]
Yan, Lifen [1 ]
Pan, Dan [1 ,2 ]
Liang, Changhong [1 ]
Liu, Zaiyi [1 ]
机构
[1] Guangdong Acad Med Sci, Guangdong Gen Hosp, Dept Radiol, Guangzhou 510080, Guangdong, Peoples R China
[2] Southern Med Univ, Grad Coll, Guangzhou, Guangdong, Peoples R China
[3] GE Healthcare China, Guangzhou, Guangdong, Peoples R China
关键词
diffusional kurtosis imaging; non-Gaussian diffusion; diffusion tensor imaging; human kidney; INTRAVOXEL INCOHERENT MOTION; WEIGHTED MRI; WHITE-MATTER; REPEATABILITY; REGISTRATION; COEFFICIENT; PARAMETERS; ANISOTROPY; HYDRATION; TENSORS;
D O I
10.1002/nbm.3235
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Our aim was to prospectively evaluate the feasibility of diffusional kurtosis imaging (DKI) in normal human kidney and to report preliminary DKI measurements. Institutional review board approval and informed consent were obtained. Forty-two healthy volunteers underwent diffusion-weighted imaging (DWI) scans with a 3-T MR scanner. b values of 0, 500 and 1000s/mm(2) were adopted. Maps of fractional anisotropy (FA), mean diffusivity (MD), radial diffusivity (D-perpendicular to), axial diffusivity (D-||), mean kurtosis (MK), radial kurtosis (K-perpendicular to) and axial kurtosis (K-||) were produced. Three representative axial slices in the upper pole, mid-zone and lower pole were selected in the left and right kidney. On each selected slice, three regions of interest were drawn on the renal cortex and another three on the medulla. Statistical comparison was performed with t-test and analysis of variance. Thirty-seven volunteers successfully completed the scans. No statistically significant differences were observed between the left and right kidney for all metrics (p values in the cortex: FA, 0.114; MD, 0.531; D-perpendicular to, 0.576; D-||, 0.691; MK, 0.934; K-perpendicular to, 0.722; K-||, 0.891; p values in the medulla: FA, 0.348; MD, 0.732; D-perpendicular to, 0.470; D-||, 0.289; MK, 0.959; K-perpendicular to, 0.780; K-||, 0.287). Kurtosis metrics (MK, K-||, K-perpendicular to) obtained in the renal medulla were significantly (p <0.001) higher than those in the cortex (0.552 +/- 0.04, 0.637 +/- 0.07 and 0.530 +/- 0.08 in the medulla and 0.373 +/- 0.04, 0.492 +/- 0.06 and 0.295 +/- 0.06 in the cortex, respectively). For the diffusivity measures, FA of the medulla (0.356 +/- 0.03) was higher than that of the cortex (0.179 +/- 0.03), whereas MD, D-perpendicular to and D-|| (mm(2)/ms) were lower in the medulla than in the cortex (3.88 +/- 0.09, 3.50 +/- 0.23 and 4.65 +/- 0.29 in the cortex and 2.88 +/- 0.11, 2.32 +/- 0.20 and 3.47 +/- 0.31 in the medulla, respectively). Our results indicate that DKI is feasible in the human kidney. We have reported the preliminary DKI measurements of normal human kidney that demonstrate well the non-Gaussian behavior of water diffusion, especially in the renal medulla. Copyright (c) 2014 John Wiley & Sons, Ltd.
引用
收藏
页码:154 / 161
页数:8
相关论文
共 50 条
  • [21] Whole-Body Diffusion Kurtosis Imaging Initial Experience on Non-Gaussian Diffusion in Various Organs
    Filli, Lukas
    Wurnig, Moritz
    Nanz, Daniel
    Luechinger, Roger
    Kenkel, David
    Boss, Andreas
    INVESTIGATIVE RADIOLOGY, 2014, 49 (12) : 773 - 778
  • [22] Characterizing Non-Gaussian, High b-value Diffusion in Liver Fibrosis: Stretched Exponential and Diffusional Kurtosis Modeling
    Anderson, Stephan W.
    Barry, Brian
    Soto, Jorge
    Ozonoff, Al
    O'Brien, Michael
    Jara, Hernan
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (04) : 827 - 834
  • [23] Evaluation of non-Gaussian diffusion in cardiac MRI
    McClymont, Darryl
    Teh, Irvin
    Carruth, Eric
    Omens, Jeffrey
    McCulloch, Andrew
    Whittington, Hannah J.
    Kohl, Peter
    Grau, Vicente
    Schneider, Jurgen E.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (03) : 1174 - 1186
  • [24] Non-gaussian diffusion evaluation of the human kidney by Pade exponent model
    Ljimani, Alexandra
    Lanzman, Rotem S.
    Mueller-Lutz, Anja
    Antoch, Gerald
    Wittsack, Hans-Joerg
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 47 (01) : 160 - 167
  • [25] Non-Gaussian normal diffusion induced by delocalization
    Wang, Jianjin
    Zhang, Yong
    Zhao, Hong
    PHYSICAL REVIEW E, 2016, 93 (03)
  • [26] Comparison of non-Gaussian and Gaussian diffusion models of diffusion weighted imaging of rectal cancer at 3.0 T MRI
    Guangwen Zhang
    Shuangshuang Wang
    Didi Wen
    Jing Zhang
    Xiaocheng Wei
    Wanling Ma
    Weiwei Zhao
    Mian Wang
    Guosheng Wu
    Jinsong Zhang
    Scientific Reports, 6
  • [27] Comparison of non-Gaussian and Gaussian diffusion models of diffusion weighted imaging of rectal cancer at 3.0 T MRI
    Zhang, Guangwen
    Wang, Shuangshuang
    Wen, Didi
    Zhang, Jing
    Wei, Xiaocheng
    Ma, Wanling
    Zhao, Weiwei
    Wang, Mian
    Wu, Guosheng
    Zhang, Jinsong
    SCIENTIFIC REPORTS, 2016, 6
  • [28] Renal interstitial fibrotic assessment using non-Gaussian diffusion kurtosis imaging in a rat model of hyperuricemia
    Chen, Ping-Kang
    Cheng, Zhong-Yuan
    Wang, Ya-Lin
    Xu, Bao-Jun
    Yu, Zong-Chao
    Li, Zhao-Xia
    Gong, Shang-Ao
    Zhang, Feng-Tao
    Qian, Long
    Cui, Wei
    Feng, You-Zhen
    Cai, Xiang-Ran
    BMC MEDICAL IMAGING, 2024, 24 (01)
  • [29] Renal interstitial fibrotic assessment using non-Gaussian diffusion kurtosis imaging in a rat model of hyperuricemia
    Ping-Kang Chen
    Zhong-Yuan Cheng
    Ya-Lin Wang
    Bao-Jun Xu
    Zong-Chao Yu
    Zhao-Xia Li
    Shang-Ao Gong
    Feng-Tao Zhang
    Long Qian
    Wei Cui
    You-Zhen Feng
    Xiang-Ran Cai
    BMC Medical Imaging, 24
  • [30] Non-Gaussian Diffusion MRI for Evaluating Hepatic Fibrosis
    Li, Weiguo
    ACADEMIC RADIOLOGY, 2022, 29 (07) : 964 - 966