MRI quantification of non-Gaussian water diffusion in normal human kidney: a diffusional kurtosis imaging study

被引:71
|
作者
Huang, Yanqi [1 ,2 ]
Chen, Xin [1 ,2 ]
Zhang, Zhongping [3 ]
Yan, Lifen [1 ]
Pan, Dan [1 ,2 ]
Liang, Changhong [1 ]
Liu, Zaiyi [1 ]
机构
[1] Guangdong Acad Med Sci, Guangdong Gen Hosp, Dept Radiol, Guangzhou 510080, Guangdong, Peoples R China
[2] Southern Med Univ, Grad Coll, Guangzhou, Guangdong, Peoples R China
[3] GE Healthcare China, Guangzhou, Guangdong, Peoples R China
关键词
diffusional kurtosis imaging; non-Gaussian diffusion; diffusion tensor imaging; human kidney; INTRAVOXEL INCOHERENT MOTION; WEIGHTED MRI; WHITE-MATTER; REPEATABILITY; REGISTRATION; COEFFICIENT; PARAMETERS; ANISOTROPY; HYDRATION; TENSORS;
D O I
10.1002/nbm.3235
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Our aim was to prospectively evaluate the feasibility of diffusional kurtosis imaging (DKI) in normal human kidney and to report preliminary DKI measurements. Institutional review board approval and informed consent were obtained. Forty-two healthy volunteers underwent diffusion-weighted imaging (DWI) scans with a 3-T MR scanner. b values of 0, 500 and 1000s/mm(2) were adopted. Maps of fractional anisotropy (FA), mean diffusivity (MD), radial diffusivity (D-perpendicular to), axial diffusivity (D-||), mean kurtosis (MK), radial kurtosis (K-perpendicular to) and axial kurtosis (K-||) were produced. Three representative axial slices in the upper pole, mid-zone and lower pole were selected in the left and right kidney. On each selected slice, three regions of interest were drawn on the renal cortex and another three on the medulla. Statistical comparison was performed with t-test and analysis of variance. Thirty-seven volunteers successfully completed the scans. No statistically significant differences were observed between the left and right kidney for all metrics (p values in the cortex: FA, 0.114; MD, 0.531; D-perpendicular to, 0.576; D-||, 0.691; MK, 0.934; K-perpendicular to, 0.722; K-||, 0.891; p values in the medulla: FA, 0.348; MD, 0.732; D-perpendicular to, 0.470; D-||, 0.289; MK, 0.959; K-perpendicular to, 0.780; K-||, 0.287). Kurtosis metrics (MK, K-||, K-perpendicular to) obtained in the renal medulla were significantly (p <0.001) higher than those in the cortex (0.552 +/- 0.04, 0.637 +/- 0.07 and 0.530 +/- 0.08 in the medulla and 0.373 +/- 0.04, 0.492 +/- 0.06 and 0.295 +/- 0.06 in the cortex, respectively). For the diffusivity measures, FA of the medulla (0.356 +/- 0.03) was higher than that of the cortex (0.179 +/- 0.03), whereas MD, D-perpendicular to and D-|| (mm(2)/ms) were lower in the medulla than in the cortex (3.88 +/- 0.09, 3.50 +/- 0.23 and 4.65 +/- 0.29 in the cortex and 2.88 +/- 0.11, 2.32 +/- 0.20 and 3.47 +/- 0.31 in the medulla, respectively). Our results indicate that DKI is feasible in the human kidney. We have reported the preliminary DKI measurements of normal human kidney that demonstrate well the non-Gaussian behavior of water diffusion, especially in the renal medulla. Copyright (c) 2014 John Wiley & Sons, Ltd.
引用
收藏
页码:154 / 161
页数:8
相关论文
共 50 条
  • [1] Diffusional kurtosis imaging: The quantification of non-Gaussian water diffusion by means of magnetic resonance imaging
    Jensen, JH
    Helpern, JA
    Ramani, A
    Lu, HZ
    Kaczynski, K
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (06) : 1432 - 1440
  • [2] MRI quantification of non-Gaussian water diffusion by kurtosis analysis
    Jensen, Jens H.
    Helpern, Joseph A.
    NMR IN BIOMEDICINE, 2010, 23 (07) : 698 - 710
  • [3] Non-Gaussian water diffusion kurtosis imaging of prostate cancer
    Suo, Shiteng
    Chen, Xiaoxi
    Wu, Lianming
    Zhang, Xiaofei
    Yao, Qiuying
    Fan, Yu
    Wang, He
    Xu, Jianrong
    MAGNETIC RESONANCE IMAGING, 2014, 32 (05) : 421 - 427
  • [4] Application of non-Gaussian water diffusional kurtosis imaging in the assessment of uterine tumors: A preliminary study
    Dia, Aliou Amadou
    Hori, Masatoshi
    Onishi, Hiromitsu
    Sakane, Makoto
    Ota, Takashi
    Tsuboyama, Takahiro
    Tatsumi, Mitsuaki
    Okuaki, Tomoyuki
    Tomiyama, Noriyuki
    PLOS ONE, 2017, 12 (11):
  • [5] Visualizing Non-Gaussian Diffusion: Clinical Application of q-Space Imaging and Diffusional Kurtosis Imaging of the Brain and Spine
    Hori, Masaaki
    Fukunaga, Issei
    Masutani, Yoshitaka
    Taoka, Toshiaki
    Kamagata, Koji
    Suzuki, Yuriko
    Aoki, Shigeki
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2012, 11 (04) : 221 - 233
  • [6] Investigation of the Non-Gaussian Water Diffusion Properties in Bladder Cancer Using Diffusion Kurtosis Imaging: A Preliminary Study
    Suo, Shiteng
    Chen, Xiaoxi
    Ji, Xiang
    Zhuang, Zhiguo
    Wu, Lianming
    Yao, Qiuying
    Fan, Yu
    Xu, Jianrong
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (02) : 281 - 285
  • [7] Toward a Standardized Approach to Estimate Kurtosis in Body Applications of a Non-Gaussian Diffusion Kurtosis Imaging Model of Water Diffusion
    Giannelli, Marco
    Marzi, Chiara
    Mascalchi, Mario
    Diciotti, Stefano
    Tessa, Carlo
    RADIOLOGY, 2017, 285 (01) : 329 - 330
  • [8] Regional and tissue-type based assessment of Gaussian and non-Gaussian diffusion MRI indices in three subtypes of multiple sclerosis using diffusional kurtosis imaging
    Lee, P.
    Adany, P.
    Danney, D. R.
    Hughes, A. J.
    Lynch, S. G.
    Choi, I. -Y.
    MULTIPLE SCLEROSIS JOURNAL, 2015, 21 : 497 - 498
  • [9] Diffusional kurtosis imaging in head and neck cancer: On the use of trace-weighted images to estimate indices of non-Gaussian water diffusion
    Marzi, Simona
    Minosse, Silvia
    Vidiri, Antonello
    Piludu, Francesca
    Giannelli, Marco
    MEDICAL PHYSICS, 2018, 45 (12) : 5411 - 5419
  • [10] Magnetic resonance quantification of non-Gaussian water diffusion in hepatic fibrosis staging: a pilot study of diffusion kurtosis imaging to identify reversible hepatic fibrosis
    Liu, Tang
    Hu, Jiawei
    Liu, Yajie
    Chen, Honghai
    Guo, Dongmei
    ANNALS OF TRANSLATIONAL MEDICINE, 2021, 9 (20)