Use of implanted gold fiducial markers with MV-CBCT image-guided IMRT for pancreatic tumours

被引:7
|
作者
Packard, Matthew [1 ]
Gayou, Olivier [2 ]
Gurram, Krishna [3 ]
Weiss, Brandon [2 ]
Thakkar, Shyam [3 ]
Kirichenko, Alexander [2 ]
机构
[1] Spectrum Hlth, Dept Radiat Oncol, Lemmen Holton Canc Pavil, Grand Rapids, MI 49503 USA
[2] Allegheny Gen Hosp, Allegheny Hlth Network, Dept Radiat Oncol, Pittsburgh, PA 15212 USA
[3] Allegheny Gen Hosp, Allegheny Hlth Network, Ctr Digest Hlth, Pittsburgh, PA 15212 USA
关键词
fiducial marker; image-guidance; IMRT; pancreatic cancer; target motion; RADIATION-THERAPY; CANCER; RADIOTHERAPY; MOTION; SYSTEM;
D O I
10.1111/1754-9485.12294
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
IntroductionVisualisation of soft tissues such as pancreatic tumours by mega-voltage cone beam CT (MV-CBCT) is frequently difficult and daily localisation is often based on more easily seen adjacent bony anatomy. Fiducial markers implanted into pancreatic tumours serve as surrogates for tumour position and may more accurately represent absolute tumour position. Differences in daily shifts based on alignment to implanted fiducial markers vs. alignment to adjacent bony anatomy were compared. MethodsGold fiducial markers were placed into the pancreatic tumour under endoscopic ultrasound (EUS) guidance in 12 patients. Patients subsequently received image-guided intensity-modulated radiation therapy (IG-IMRT). MV-CBCT was performed prior to each fraction and isocentre shifts were performed based on alignment to the fiducial markers. We retrospectively reviewed archived MV-CBCT datasets and calculated shift differences in the left-right (LR), superior-inferior (SI) and anterior-posterior (AP) axes relative to shifts based on alignment to adjacent bony anatomy. ResultsTwo hundred forty-three fractions were analysed. The mean absolute difference in isocentre shifts between the fiducial markers and those aligned to bony anatomy was 3.4mm (range 0-13mm), 6.3mm (range 0-21mm) and 2.6mm (range 0-12mm), in LR, SI and AP directions, respectively. The mean three-dimensional vector shift difference between markers vs. bony anatomy alignment was 8.6mm. ConclusionsThese data suggest that fiducial markers used in conjunction with MV-CBCT improve the accuracy of daily target delineation compared with localisation using adjacent bony anatomy and that gold fiducial markers using MV-CBCT alignment are a viable option for target localisation during IG-IMRT.
引用
收藏
页码:499 / 506
页数:8
相关论文
共 50 条
  • [41] MR image-based synthetic CT for IMRT prostate treatment planning and CBCT image-guided localization
    Chen, Shupeng
    Quan, Hong
    Qin, An
    Yee, Seonghwan
    Yan, Di
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (03): : 236 - 245
  • [42] Transperineal implantation of gold fiducial markers (gold seeds) for prostate image-guided radiation therapy: a feasible technique associated with a low risk of complications
    Saad, Akram
    Goldstein, Jeffrey
    Lawrence, Yaacov Richard
    Weiss, Ilana
    Saad, Rasha
    Spieler, Benjamin
    Symon, Zvi
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2015, 62 (04): : 261 - 266
  • [43] A Study of the Dosimetric Impact of Gold Fiducial Markers in Image Guided Radiation Therapy
    Wang, L.
    Mok, E.
    Xing, L.
    Wang, L.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [44] Comparison of localization performance with implanted fiducial markers and cone-beam computed tomography for on-line image-guided radiotherapy of the prostate
    Moseley, Douglas J.
    White, Elizabeth A.
    Wiltshire, Kirsty L.
    Rosewall, Tara
    Sharpe, Michael B.
    Siewerdsen, Jeffrey H.
    Bissonnette, Jean-Pierre
    Gospodarowicz, Mary
    Warde, Padraig
    Catton, Charles N.
    Jaffray, David A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (03): : 942 - 953
  • [45] HIGH RETENTION AND SAFETY OF PERCUTANEOUSLY IMPLANTED ENDOVASCULAR EMBOLIZATION COILS AS FIDUCIAL MARKERS FOR IMAGE-GUIDED STEREOTACTIC ABLATIVE RADIOTHERAPY OF PULMONARY TUMORS
    Hong, Julian C.
    Yu, Yao
    Rao, Aarti K.
    Ditererich, Sonja
    Maxim, Peter G.
    Le, Quynh-Thu
    Diehn, Maximilian
    Sze, Daniel Y.
    Kothary, Nishita
    Loo, Billy W., Jr.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (01): : 85 - 90
  • [46] High Retention and Safety of Percutaneously Implanted Endovascular Embolization Coils as Fiducial Markers for Image-guided Stereotactic Ablative Radiotherapy of Pulmonary Tumors
    Hong, J. C.
    Yu, Y.
    Rao, A. K.
    Dieterich, S.
    Maxim, P. G.
    Le, Q. T.
    Diehn, M.
    Sze, D. Y.
    Kothary, N.
    Loo, B. W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S518 - S519
  • [47] Image-guided radiation therapy for post-operative gynaecologic cancer: patient set up verification with and without implanted fiducial markers
    Murrell, Donna H.
    Warner, Andrew
    Benwell, Quinn
    Wells, Wendy
    Scott, Danielle
    Velker, Vikram
    Hajdok, George
    D'Souza, David P.
    ACTA ONCOLOGICA, 2018, 57 (10) : 1346 - 1351
  • [48] A fiducial detection algorithm for real-time image guided IMRT based on simultaneous MV and kV imaging
    Mao, Weihua
    Riaz, Nadeem
    Lee, Louis
    Wiersma, Rodney
    Xing, Lei
    MEDICAL PHYSICS, 2008, 35 (08) : 3554 - 3564
  • [49] Feasibility of endoscopic fiducial marker implantation in the stomach for use in image-guided RT
    Bleeker, M.
    Pouw, R.
    Bel, A.
    Sonke, J.
    Hulshof, M.
    van der Horst, A.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1103 - S1105
  • [50] Novel liquid fiducial tissue marker with potential use in image-guided radiotherapy
    Schaarup-Jensen, Henrik
    Jolck, Rasmus
    Hansen, Anders
    Jensen, Andreas
    Bruun, Linda
    Christensen, Anders
    Scherman, Per Bengtsson
    Kjaer, Andreas
    Clausen, Mads
    Andresen, Thomas
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2015, 250