Use of implanted gold fiducial markers with MV-CBCT image-guided IMRT for pancreatic tumours

被引:7
|
作者
Packard, Matthew [1 ]
Gayou, Olivier [2 ]
Gurram, Krishna [3 ]
Weiss, Brandon [2 ]
Thakkar, Shyam [3 ]
Kirichenko, Alexander [2 ]
机构
[1] Spectrum Hlth, Dept Radiat Oncol, Lemmen Holton Canc Pavil, Grand Rapids, MI 49503 USA
[2] Allegheny Gen Hosp, Allegheny Hlth Network, Dept Radiat Oncol, Pittsburgh, PA 15212 USA
[3] Allegheny Gen Hosp, Allegheny Hlth Network, Ctr Digest Hlth, Pittsburgh, PA 15212 USA
关键词
fiducial marker; image-guidance; IMRT; pancreatic cancer; target motion; RADIATION-THERAPY; CANCER; RADIOTHERAPY; MOTION; SYSTEM;
D O I
10.1111/1754-9485.12294
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
IntroductionVisualisation of soft tissues such as pancreatic tumours by mega-voltage cone beam CT (MV-CBCT) is frequently difficult and daily localisation is often based on more easily seen adjacent bony anatomy. Fiducial markers implanted into pancreatic tumours serve as surrogates for tumour position and may more accurately represent absolute tumour position. Differences in daily shifts based on alignment to implanted fiducial markers vs. alignment to adjacent bony anatomy were compared. MethodsGold fiducial markers were placed into the pancreatic tumour under endoscopic ultrasound (EUS) guidance in 12 patients. Patients subsequently received image-guided intensity-modulated radiation therapy (IG-IMRT). MV-CBCT was performed prior to each fraction and isocentre shifts were performed based on alignment to the fiducial markers. We retrospectively reviewed archived MV-CBCT datasets and calculated shift differences in the left-right (LR), superior-inferior (SI) and anterior-posterior (AP) axes relative to shifts based on alignment to adjacent bony anatomy. ResultsTwo hundred forty-three fractions were analysed. The mean absolute difference in isocentre shifts between the fiducial markers and those aligned to bony anatomy was 3.4mm (range 0-13mm), 6.3mm (range 0-21mm) and 2.6mm (range 0-12mm), in LR, SI and AP directions, respectively. The mean three-dimensional vector shift difference between markers vs. bony anatomy alignment was 8.6mm. ConclusionsThese data suggest that fiducial markers used in conjunction with MV-CBCT improve the accuracy of daily target delineation compared with localisation using adjacent bony anatomy and that gold fiducial markers using MV-CBCT alignment are a viable option for target localisation during IG-IMRT.
引用
收藏
页码:499 / 506
页数:8
相关论文
共 50 条
  • [31] Novel fiducial marker has optimal characteristics for image-guided radiotherapy of abdominal tumours
    Stefanowicz, S.
    Moeller, M. L.
    Thiele, J.
    Jaster, M.
    Hoinkis, C.
    Troost, E. G. C.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S916 - S916
  • [32] Can an ultrasound replace fiducial markers for prostate image-guided radiation therapy?
    Johnston, H.
    Hilts, M.
    Beckham, W.
    Berthelet, E.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S26 - S26
  • [33] EUS guided gold fiducial insertion for image guided radiation therapy of pancreatic cancer
    Yan, Brian M.
    Scheilenberg, Devin
    Koong, Albert C.
    Van Dam, Jacques
    GASTROINTESTINAL ENDOSCOPY, 2008, 67 (05) : AB225 - AB225
  • [34] Comparison of implanted fiducial markers and self-expandable metallic stents for pancreatic image guided radiation therapy localization
    Pepin, Eric
    Olsen, Lindsey
    Badiyan, Shahed
    Murad, Faris
    Mullady, Daniel
    Wang-Gillam, Andrea
    Linehan, David
    Parikh, Parag
    Olsen, Jeffrey
    PRACTICAL RADIATION ONCOLOGY, 2015, 5 (03) : E193 - E199
  • [35] EUS-guided gold fiducial insertion for image-guided radiation therapy of pancreatic cancer: 50 successful cases without fluoroscopy
    Park, Walter G.
    Yan, Brian M.
    Schellenberg, Devin
    Kim, Jeff
    Chang, Daniel T.
    Koong, Albert
    Patalano, Cheryl
    Van Dam, Jacques
    GASTROINTESTINAL ENDOSCOPY, 2010, 71 (03) : 513 - 518
  • [36] Feasibility of Gold Fiducial Markers as a Surrogate for Gross Tumor Volume Position in Image-Guided Radiation Therapy of Rectal Cancer
    van den Ende, Roy P. J.
    Kerkhof, Ellen M.
    Rigter, Lisanne S.
    van Leerdam, Monique E.
    Peters, Femke P.
    van Triest, Baukelien
    Staring, Marius
    Marijnen, Corrie A. M.
    van der Heide, Uulke A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (05): : 1151 - 1159
  • [37] Determination of optimal fiducial marker across image-guided radiation therapy (IGRT) modalities: visibility and artifact analysis of gold, carbon, and polymer fiducial markers
    Handsfield, Lydia L.
    Yue, Ning J.
    Zhou, Jinghao
    Chen, Ting
    Goyal, Sharad
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (05): : 181 - 189
  • [38] Implanted gold seeds for tumour bed localisation and image-guided radiotherapy
    Coles, C. E.
    Wishart, G. C.
    Fairfoul, J.
    Donovan, E.
    Harris, E.
    Poynter, A.
    Wilkinson, J. S.
    Tudor, S.
    Yarnold, J.
    EJC SUPPLEMENTS, 2007, 5 (03): : 6 - 6
  • [39] Polymark™ fiducial markers migration in Prostate Image Guided Radiation Therapy using CBCT images
    Camacho, C.
    Valduvieco, I.
    Saez, J.
    Herreros, A.
    Garcia-Miguel, J.
    Agusti, E.
    Castro, C.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S897 - S898
  • [40] EUS-guided placement of fiducial markers for image-guided radiotherapy in gastrointestinal tumors: A critical appraisal
    Carrara, Silvia
    Rimbas, Mihai
    Larghi, Alberto
    Di Leo, Milena
    Comito, Tiziana
    Jaoude, Joseph Abi
    Taniguchi, Cullen M.
    Dietrich, Christoph F.
    Bhutani, Manoop S.
    Hollerbach, Stephan
    ENDOSCOPIC ULTRASOUND, 2021, 10 (06) : 414 - 423