Quantification of Sub-Nanomolar Levels of Gallic Acid by Adsorptive Stripping Voltammetry

被引:0
|
作者
Abbasi, S. [1 ]
Daneshfar, A. [1 ]
Hamdghadareh, S. [1 ]
Farmany, A. [2 ]
机构
[1] Ilam Univ, Dept Chem, Ilam, Iran
[2] Islamic Azad Univ, Hamedan Branch, Hamadan, Iran
来源
关键词
Gallic acid; Adsorptive stripping voltammetry; Antioxidant; PHENOLIC-ACIDS;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The voltammetric behavior of gallic acid (GA) on a hanging mercury drop electrode (HMDE) has been investigated by cathodic adsorptive stripping voltammetry (AdCSV). Gallic acid (3,4,5-trihydroxybenzoic acid) is a natural phenolic compound which can generate a well defined reduction peak at around -1.04 V (versus Ag/AgCl) in 0.1 M borax buffer solution (pH 7.53). The parameters affecting the response of gallic acid, such as pH, accumulation time, accumulation potential and scan rate are optimized for the determination of GA. Under the optimized conditions, the peak current change linearly with the GA concentration in the range of 0.1 to 600 ng/ml. The lowest detectable concentration of GA is 0.05 ng/ml after 100 s accumulation time. The method has been successfully applied to the determination of GA in tea, urine and plasma blood serum. The results show that the sensitivity of the method is highest among the existing methods.
引用
收藏
页码:4843 / 4852
页数:10
相关论文
共 50 条
  • [41] THE DETERMINATION OF TRACE LEVELS OF IRON IN SEAWATER USING ADSORPTIVE CATHODIC STRIPPING VOLTAMMETRY
    VAN DEN BERG, CMG
    NIMMO, M
    ABOLLINO, O
    MENTASTI, E
    [J]. ELECTROANALYSIS, 1991, 3 (06) : 477 - 484
  • [42] Application of a Partial Least Squares Regression for the Determination of Nanomolar Concentrations of Scandium in the Presence of Nickel by Adsorptive Stripping Voltammetry
    Jakubowska, Malgorzata
    Piech, Robert
    Gorski, Lukasz
    [J]. ELECTROANALYSIS, 2013, 25 (07) : 1727 - 1733
  • [43] Braided copper cobaltite/MWCNT composites enable acetylcholine detection at sub-nanomolar levels in vitro
    Poolakkandy, Rasha Rahman
    Ramalakshmi, Neelakandan Annamalai
    Padmalayam, Krishna Aravind
    Krishnamurthy, Rajanikant Golgodu
    Menamparambath, Mini Mol
    [J]. SENSORS & DIAGNOSTICS, 2023, 2 (03): : 726 - 735
  • [44] MEASUREMENT OF ULTRATRACE LEVELS OF CHROMIUM BY ADSORPTIVE CATALYTIC STRIPPING VOLTAMMETRY IN THE PRESENCE OF CUPFERRON
    WANG, J
    LU, JM
    OLSEN, K
    [J]. ANALYST, 1992, 117 (12) : 1913 - 1917
  • [45] Application of adsorptive stripping voltammetry to the determination of trace levels of titanium in mice organs
    Pereira, MD
    Pereira, MD
    [J]. ELECTROANALYSIS, 1999, 11 (16) : 1207 - 1210
  • [46] DETERMINATION OF NUCLEIC-ACID BASES AT NANOMOLAR CONCENTRATIONS BY MEANS OF CATHODIC STRIPPING VOLTAMMETRY
    PALECEK, E
    [J]. ANALYTICAL LETTERS PART B-CLINICAL AND BIOCHEMICAL ANALYSIS, 1980, 13 (05): : 331 - 345
  • [47] DETERMINATION OF TRACE 6-AMINO PENICILLANIC ACID BY ADSORPTIVE STRIPPING VOLTAMMETRY
    HU, SS
    ZHAO, ZF
    [J]. ANALYTICAL LETTERS, 1991, 24 (05) : 827 - 836
  • [48] Ultra-sensitive quantification of copper in food and water samples by electrochemical adsorptive stripping voltammetry
    Goudarziafshar, Hamid
    Nikoorazm, Mohsen
    Mortazavi, Sayede Shima
    Abbasi, Shahryar
    Farmany, Abbas
    [J]. ENVIRONMENTAL MONITORING AND ASSESSMENT, 2013, 185 (11) : 8823 - 8829
  • [49] The Use of a Solid Bismuth Microelectrode for Vanadium Quantification by Adsorptive Stripping Voltammetry in Environmental Water Samples
    Grabarczyk, Malgorzata
    Adamczyk, Marzena
    Wlazlowska, Edyta
    [J]. MOLECULES, 2022, 27 (07):
  • [50] Determination of Hg(II) at sub-nanomolar levels: A comparative study with nanofibrous materials and continuous thin films
    Ongun, Merve Zeyrek
    Ertekin, Kadriye
    Hizliates, Cevher Gundogdu
    Oter, Ozlem
    Ergun, Yavuz
    Celik, Erdal
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2013, 181 : 244 - 250