The design of high precision three axis fluxgate magnetometer

被引:0
|
作者
Gao, Yang [1 ]
Li, Zhihua [1 ]
Li, Yongtao [2 ]
Gan, Fuping [3 ]
机构
[1] China Univ Geosci, Sch Automat, Wuhan 430074, Hubei, Peoples R China
[2] China Univ Geosci, Inst Geophys & Geomat, Wuhan 430074, Hubei, Peoples R China
[3] UNESCO, Key Lab Karst Dynam MLR & Guangxi PRC, IRCK, Guilin 541004, Peoples R China
关键词
weak magnetic anomaly; three axis fluxgate magnetometer; channel difference least squares method; proton magetometer; CALIBRATION;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
For the field of weak magnetic anomaly measurement, a high precision three axis fluxgate magnetometer MAG-XYZ is designed, which has a wide dynamic measurement range (0 similar to +/- 100000nT), high measurement accuracy (24-bit analog-to-digital converter) and 2K Hz sampling rate. The basic working principle of FGM3D / 100 sensor is described, and the composition of the three axis fluxgate magnetometer is introduced in detail. Aiming at the three-channel scale factor and zero deviation of the magnetometer aquisition unit, a multi-channel inconsistency correction of the magnetron acquisition system with least squares method is proposed. And compared with the GSM-19T proton magnetometer, the RMS error of the three axis fluxgate magnetometer is reduced from 1.506 to less than 0.157. It is shown that the method can effectively reduce the error, and improve the accuracy of the three- component magnetometer.
引用
收藏
页码:249 / 253
页数:5
相关论文
共 50 条
  • [1] Three Axis Fluxgate Magnetometer Sensor Calibration
    Hosseinzadeh, Ali
    Khayatian, Alireza
    Karimagahee, Paknoosh
    Daneshmandi, Omidreza
    Raeisy, Behrooz
    [J]. 2019 27TH IRANIAN CONFERENCE ON ELECTRICAL ENGINEERING (ICEE 2019), 2019, : 431 - 436
  • [2] Design, fabrication and characterisation of a three-axis, ring-core fluxgate magnetometer
    Ali Mosahebfard
    Omidreza Daneshmandi
    Ali Hosseinzadeh
    Mohammad Abdi
    Mahsa Yazdjerdy
    [J]. Pramana, 2021, 95
  • [3] Design, fabrication and characterisation of a three-axis, ring-core fluxgate magnetometer
    Mosahebfard, Ali
    Daneshmandi, Omidreza
    Hosseinzadeh, Ali
    Abdi, Mohammad
    Yazdjerdy, Mahsa
    [J]. PRAMANA-JOURNAL OF PHYSICS, 2021, 95 (03):
  • [4] A Novel Linear Calibration Model for Three-Axis Fluxgate Magnetometer
    Liu, Jianguo
    Li, Xiangang
    Yan, Shenggang
    Yan, Youyu
    Jia, Wei
    Zhang, Qingguo
    [J]. IEEE SENSORS JOURNAL, 2021, 21 (21) : 23917 - 23925
  • [5] Three Axis Fluxgate Magnetometer Array Calibration Using Nonmagnetic Rotation Platform
    Pang, Hongfeng
    Chen, Dixiang
    Pan, Mengchun
    Zhang, Qi
    Luo, Shitu
    Li, Ji
    Luo, Feilu
    [J]. SENSOR LETTERS, 2013, 11 (08) : 1420 - 1425
  • [6] Design of digital fluxgate magnetometer
    Cerman, A
    Ripka, P
    [J]. BEC 2002: Proceedings of the 8th Biennial Baltic Electronic Conference, 2002, : 183 - 186
  • [7] A MINIATURE 2-AXIS FLUXGATE MAGNETOMETER
    ACUNA, MH
    PELLERIN, CJ
    [J]. IEEE TRANSACTIONS ON GEOSCIENCE ELECTRONICS, 1969, GE 7 (04): : 252 - &
  • [8] High-precision Calibration of the Fluxgate Magnetometer Offset Vector in the Terrestrial Magnetosheath
    Wang, Guoqiang
    [J]. ASTROPHYSICAL JOURNAL, 2022, 929 (01):
  • [9] Design of a fourth harmonic fluxgate magnetometer
    Cruz, JC
    Trujillo, H
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 1999, 78 (2-3) : 71 - 73
  • [10] Digital fluxgate magnetometer: design notes
    Belyayev, Serhiy
    Ivchenko, Nickolay
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2015, 26 (12)