Improved quantitative myocardial T2 mapping: Impact of the fitting model

被引:60
|
作者
Akcakaya, Mehmet [1 ,2 ]
Basha, Tamer A. [1 ,2 ]
Weingaertner, Sebastian [1 ,2 ,3 ]
Roujol, Sebastien [1 ,2 ]
Berg, Sophie [1 ,2 ]
Nezafat, Reza [1 ,2 ]
机构
[1] Beth Israel Deaconess Med Ctr, Dept Med, Div Cardiovasc, Boston, MA 02215 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Heidelberg Univ, Univ Med Ctr Mannheim, Comp Assisted Clin Med, Mannheim, Germany
关键词
quantitative myocardial tissue characterization; myocardial T-2 mapping; three-parameter fit; myocardial inflammation; CARDIOVASCULAR MAGNETIC-RESONANCE; ACUTE CORONARY SYNDROME; TRANSPLANT REJECTION; T2; QUANTIFICATION; RELAXATION-TIMES; EDEMA; INFARCTION; HEART; SEQUENCES; CONTRAST;
D O I
10.1002/mrm.25377
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo develop an improved T-2 prepared (T(2)prep) balanced steady-state free-precession (bSSFP) sequence and signal relaxation curve fitting method for myocardial T-2 mapping. MethodsMyocardial T-2 mapping is commonly performed by acquisition of multiple T(2)prep bSSFP images and estimating the voxel-wise T-2 values using a two-parameter fit for relaxation. However, a two-parameter fit model does not take into account the effect of imaging pulses in a bSSFP sequence or other imperfections in T(2)prep RF pulses, which may decrease the robustness of T-2 mapping. Therefore, we propose a novel T-2 mapping sequence that incorporates an additional image acquired with saturation preparation, simulating a very long T(2)prep echo time. This enables the robust estimation of T-2 maps using a 3-parameter fit model, which captures the effect of imaging pulses and other imperfections. Phantom imaging is performed to compare the T-2 maps generated using the proposed 3-parameter model with the conventional two-parameter model, as well as a spin echo reference. In vivo imaging is performed on eight healthy subjects to compare the different fitting models. ResultsPhantom and in vivo data show that the T-2 values generated by the proposed 3-parameter model fitting do not change with different choices of the T(2)prep echo times, and are not statistically different than the reference values for the phantom (P=0.10 with three T(2)prep echoes). The two-parameter model exhibits dependence on the choice of T(2)prep echo times and are significantly different than the reference values (P=0.01 with three T(2)prep echoes). ConclusionThe proposed imaging sequence in combination with a three-parameter model allows accurate measurement of myocardial T-2 values, which is independent of number and duration of T(2)prep echo times. Magn Reson Med 74:93-105, 2015. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:93 / 105
页数:13
相关论文
共 50 条
  • [31] Feasibility of Ultrashort Echo Time T2* Mapping in Comparison With T2 Mapping for Quantitative Evaluation of Meniscal Degeneration
    Ryu, Jeongah
    Lee, Sang Hoon
    Choi, Soo Yeon
    Shin, Myung Jin
    Lee, Min Hee
    Chung, Hye Won
    INVESTIGATIVE MAGNETIC RESONANCE IMAGING, 2023, 27 (01) : 49 - 55
  • [32] T2 quantification for improved detection of myocardial edema
    Giri, Shivraman
    Chung, Yiu-Cho
    Merchant, Ali
    Mihai, Georgeta
    Rajagopalan, Sanjay
    Raman, Subha V.
    Simonetti, Orlando P.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2009, 11
  • [33] T2 quantification for improved detection of myocardial edema
    Shivraman Giri
    Yiu-Cho Chung
    Ali Merchant
    Georgeta Mihai
    Sanjay Rajagopalan
    Subha V Raman
    Orlando P Simonetti
    Journal of Cardiovascular Magnetic Resonance, 11
  • [34] Quantitative T2 mapping for detecting myocardial edema after reperfusion of myocardial infarction: validation and comparison with T2-weighted images
    Chul Hwan Park
    Eui-Young Choi
    Hyuck Moon Kwon
    Bum Kee Hong
    Byoung Kwon Lee
    Young Won Yoon
    Pil-Ki Min
    Andreas Greiser
    Mun Young Paek
    Wei Yu
    Yon Mi Sung
    Sung Ho Hwang
    Yoo Jin Hong
    Tae Hoon Kim
    The International Journal of Cardiovascular Imaging, 2013, 29 : 65 - 72
  • [35] Quantitative T2 mapping for detecting myocardial edema after reperfusion of myocardial infarction: validation and comparison with T2-weighted images
    Park, Chul Hwan
    Choi, Eui-Young
    Kwon, Hyuck Moon
    Hong, Bum Kee
    Lee, Byoung Kwon
    Yoon, Young Won
    Min, Pil-Ki
    Greiser, Andreas
    Paek, Mun Young
    Yu, Wei
    Sung, Yon Mi
    Hwang, Sung Ho
    Hong, Yoo Jin
    Kim, Tae Hoon
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 : 65 - 72
  • [36] Quantitative T2 mapping to characterize the process of intervertebral disc degeneration in a rabbit model
    Wei Sun
    Kai Zhang
    Chang-qing Zhao
    Wei Ding
    Jun-jie Yuan
    Qi Sun
    Xiao-jiang Sun
    You-zhuan Xie
    Hua Li
    Jie Zhao
    BMC Musculoskeletal Disorders, 14
  • [37] Quantitative T2 mapping to characterize the process of intervertebral disc degeneration in a rabbit model
    Sun, Wei
    Zhang, Kai
    Zhao, Chang-qing
    Ding, Wei
    Yuan, Jun-jie
    Sun, Qi
    Sun, Xiao-jiang
    Xie, You-zhuan
    Li, Hua
    Zhao, Jie
    BMC MUSCULOSKELETAL DISORDERS, 2013, 14
  • [38] Quantitative T2 mapping monitoring the maturation of engineered elastic cartilage in a rabbit model
    Guojun Yang
    Xue Li
    Weiwei Zhang
    Nier Wu
    Haifeng Chen
    Xia Liu
    Haiyue Jiang
    BMC Medical Imaging, 23
  • [39] Quantitative T2 mapping monitoring the maturation of engineered elastic cartilage in a rabbit model
    Yang, Guojun
    Li, Xue
    Zhang, Weiwei
    Wu, Nier
    Chen, Haifeng
    Liu, Xia
    Jiang, Haiyue
    BMC MEDICAL IMAGING, 2023, 23 (01)
  • [40] Myocardial T2*mapping: influence of noise on accuracy and precision
    Sandino, Christopher M.
    Kellman, Peter
    Arai, Andrew E.
    Hansen, Michael S.
    Xue, Hui
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2015, 17