Improved quantitative myocardial T2 mapping: Impact of the fitting model

被引:60
|
作者
Akcakaya, Mehmet [1 ,2 ]
Basha, Tamer A. [1 ,2 ]
Weingaertner, Sebastian [1 ,2 ,3 ]
Roujol, Sebastien [1 ,2 ]
Berg, Sophie [1 ,2 ]
Nezafat, Reza [1 ,2 ]
机构
[1] Beth Israel Deaconess Med Ctr, Dept Med, Div Cardiovasc, Boston, MA 02215 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Heidelberg Univ, Univ Med Ctr Mannheim, Comp Assisted Clin Med, Mannheim, Germany
关键词
quantitative myocardial tissue characterization; myocardial T-2 mapping; three-parameter fit; myocardial inflammation; CARDIOVASCULAR MAGNETIC-RESONANCE; ACUTE CORONARY SYNDROME; TRANSPLANT REJECTION; T2; QUANTIFICATION; RELAXATION-TIMES; EDEMA; INFARCTION; HEART; SEQUENCES; CONTRAST;
D O I
10.1002/mrm.25377
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo develop an improved T-2 prepared (T(2)prep) balanced steady-state free-precession (bSSFP) sequence and signal relaxation curve fitting method for myocardial T-2 mapping. MethodsMyocardial T-2 mapping is commonly performed by acquisition of multiple T(2)prep bSSFP images and estimating the voxel-wise T-2 values using a two-parameter fit for relaxation. However, a two-parameter fit model does not take into account the effect of imaging pulses in a bSSFP sequence or other imperfections in T(2)prep RF pulses, which may decrease the robustness of T-2 mapping. Therefore, we propose a novel T-2 mapping sequence that incorporates an additional image acquired with saturation preparation, simulating a very long T(2)prep echo time. This enables the robust estimation of T-2 maps using a 3-parameter fit model, which captures the effect of imaging pulses and other imperfections. Phantom imaging is performed to compare the T-2 maps generated using the proposed 3-parameter model with the conventional two-parameter model, as well as a spin echo reference. In vivo imaging is performed on eight healthy subjects to compare the different fitting models. ResultsPhantom and in vivo data show that the T-2 values generated by the proposed 3-parameter model fitting do not change with different choices of the T(2)prep echo times, and are not statistically different than the reference values for the phantom (P=0.10 with three T(2)prep echoes). The two-parameter model exhibits dependence on the choice of T(2)prep echo times and are significantly different than the reference values (P=0.01 with three T(2)prep echoes). ConclusionThe proposed imaging sequence in combination with a three-parameter model allows accurate measurement of myocardial T-2 values, which is independent of number and duration of T(2)prep echo times. Magn Reson Med 74:93-105, 2015. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:93 / 105
页数:13
相关论文
共 50 条
  • [21] T2 and T2* Mapping
    Welsch G.H.
    Hennig F.F.
    Krinner S.
    Trattnig S.
    Current Radiology Reports, 2 (8)
  • [22] T2 mapping in myocardial disease: a comprehensive review
    Aaron T. O’Brien
    Katarzyna E. Gil
    Juliet Varghese
    Orlando P. Simonetti
    Karolina M. Zareba
    Journal of Cardiovascular Magnetic Resonance, 24
  • [23] T2 mapping in myocardial disease: a comprehensive review
    O'Brien, Aaron T.
    Gil, Katarzyna E.
    Varghese, Juliet
    Simonetti, Orlando P.
    Zareba, Karolina M.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2022, 24 (01)
  • [24] Myocardial T2 Mapping in Patients With Hypertrophic Cardiomyopathy
    Amano, Yasuo
    Yanagisawa, Fumi
    Tachi, Masaki
    Hashimoto, Hidenobu
    Imai, Shogo
    Kumita, Shinichiro
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (03) : 344 - 348
  • [25] Editorial for "Quantitative Assessment of Myocardial Edema by MR T2 Mapping in Children With Kawasaki Disease"
    Ishikawa, Takamichi
    Suwa, Kenichiro
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024, 59 (03) : 835 - 836
  • [26] Quantitative T2′-Mapping in Acute Ischemic Stroke
    Bauer, Sonja
    Wagner, Marlies
    Seiler, Alexander
    Hattingen, Elke
    Deichmann, Ralf
    Noeth, Ulrike
    Singer, Oliver C.
    STROKE, 2014, 45 (11) : 3280 - 3286
  • [27] Editorial for "Quantitative T2 Mapping of Acute Pancreatitis"
    Perles-Barbacaru, Teodora-Adriana
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024, 60 (06) : 2692 - 2693
  • [28] Quantitative Mapping of T2 Using Partial Spoiling
    Bieri, Oliver
    Scheffler, Klaus
    Welsch, Goetz H.
    Trattnig, S.
    Mamisch, Tallal C.
    Ganter, Carl
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (02) : 410 - 418
  • [29] Quantitative T2 mapping of rats with chronic hepatitis
    Wang, Xiaofeng
    Hu, Yan
    Lu, Xin
    Cai, Yu
    Shu, Jian
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2021, 21 (03)
  • [30] Characterizing Myocardial Edema and Hemorrhage Using Quantitative T2 and T2*Mapping at Multiple Time Intervals Post ST-Segment Elevation Myocardial Infarction
    Zia, Mohammad I.
    Ghugre, Nilesh R.
    Connelly, Kim A.
    Strauss, Bradley H.
    Sparkes, John D.
    Dick, Alexander J.
    Wright, Graham A.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2012, 5 (05) : 566 - 572