Improved quantitative myocardial T2 mapping: Impact of the fitting model

被引:60
|
作者
Akcakaya, Mehmet [1 ,2 ]
Basha, Tamer A. [1 ,2 ]
Weingaertner, Sebastian [1 ,2 ,3 ]
Roujol, Sebastien [1 ,2 ]
Berg, Sophie [1 ,2 ]
Nezafat, Reza [1 ,2 ]
机构
[1] Beth Israel Deaconess Med Ctr, Dept Med, Div Cardiovasc, Boston, MA 02215 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Heidelberg Univ, Univ Med Ctr Mannheim, Comp Assisted Clin Med, Mannheim, Germany
关键词
quantitative myocardial tissue characterization; myocardial T-2 mapping; three-parameter fit; myocardial inflammation; CARDIOVASCULAR MAGNETIC-RESONANCE; ACUTE CORONARY SYNDROME; TRANSPLANT REJECTION; T2; QUANTIFICATION; RELAXATION-TIMES; EDEMA; INFARCTION; HEART; SEQUENCES; CONTRAST;
D O I
10.1002/mrm.25377
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo develop an improved T-2 prepared (T(2)prep) balanced steady-state free-precession (bSSFP) sequence and signal relaxation curve fitting method for myocardial T-2 mapping. MethodsMyocardial T-2 mapping is commonly performed by acquisition of multiple T(2)prep bSSFP images and estimating the voxel-wise T-2 values using a two-parameter fit for relaxation. However, a two-parameter fit model does not take into account the effect of imaging pulses in a bSSFP sequence or other imperfections in T(2)prep RF pulses, which may decrease the robustness of T-2 mapping. Therefore, we propose a novel T-2 mapping sequence that incorporates an additional image acquired with saturation preparation, simulating a very long T(2)prep echo time. This enables the robust estimation of T-2 maps using a 3-parameter fit model, which captures the effect of imaging pulses and other imperfections. Phantom imaging is performed to compare the T-2 maps generated using the proposed 3-parameter model with the conventional two-parameter model, as well as a spin echo reference. In vivo imaging is performed on eight healthy subjects to compare the different fitting models. ResultsPhantom and in vivo data show that the T-2 values generated by the proposed 3-parameter model fitting do not change with different choices of the T(2)prep echo times, and are not statistically different than the reference values for the phantom (P=0.10 with three T(2)prep echoes). The two-parameter model exhibits dependence on the choice of T(2)prep echo times and are significantly different than the reference values (P=0.01 with three T(2)prep echoes). ConclusionThe proposed imaging sequence in combination with a three-parameter model allows accurate measurement of myocardial T-2 values, which is independent of number and duration of T(2)prep echo times. Magn Reson Med 74:93-105, 2015. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:93 / 105
页数:13
相关论文
共 50 条
  • [1] Inline myocardial t2* mapping with iterative robust fitting
    Saurabh Shah
    Hui Xue
    Andreas Greiser
    Peter Weale
    Taigang He
    David N Firmin
    Dudley J Pennell
    Sven Zuehlsdorff
    Jens Guehring
    Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)
  • [2] Impact of motion correction on reproducibility and spatial variability of quantitative myocardial T2 mapping
    Roujol, Sebastien
    Basha, Tamer A.
    Weingaertner, Sebastian
    Akcakaya, Mehmet
    Berg, Sophie
    Manning, Warren J.
    Nezafat, Reza
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2015, 17
  • [3] Impact of motion correction on reproducibility and spatial variability of quantitative myocardial T2 mapping
    Sébastien Roujol
    Tamer A. Basha
    Sebastian Weingärtner
    Mehmet Akçakaya
    Sophie Berg
    Warren J. Manning
    Reza Nezafat
    Journal of Cardiovascular Magnetic Resonance, 17
  • [4] Precision and reproducibility of T2 quantifications in myocardial T2 mapping: impact of the number of echoes and reconstruction model
    Tamer Basha
    Mehmet Akcakaya
    Sébastien Roujol
    Reza Nezafat
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [5] Reproducibility and repeatability of quantitative T2 and T2*mapping of osteosarcomas in a mouse model
    Roudi, Raheleh
    Pisani, Laura J.
    Pisani, Fabrizio
    Liang, Tie
    Daldrup-Link, Heike E.
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2024, 8 (01)
  • [6] An improved method for retrospective motion correction in quantitative T2*mapping
    Noeth, Ulrike
    Volz, Steffen
    Hattingen, Elke
    Deichrnann, Ralf
    NEUROIMAGE, 2014, 92 : 106 - 119
  • [7] Motion correction for free breathing quantitative myocardial t2 mapping: impact on reproducibility and spatial variability
    Sébastien Roujol
    Tamer A Basha
    Sebastian Weingartner
    Mehmet Akcakaya
    Sophie Berg
    Warren J Manning
    Reza Nezafat
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [8] Robust myocardial T2 and T2* mapping at 3T
    Arshad Zaman
    David M Higgins
    Marc Kouwenhoven
    Ananth Kidambi
    John P Greenwood
    Sven Plein
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [9] Myocardial T2 mapping for improved detection of inflammatory myocardial involvement in acute and chronic myocarditis
    Rocio Hinojar
    Lucy Foote
    Eduardo Arroyo Ucar
    Darius Dabir
    Bernhard Schnackenburg
    David M Higgins
    Tobias Schaeffter
    Eike Nagel
    Valentina Puntmann
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [10] Myocardial T2 mapping for improved detection of inflammatory myocardial involvement in acute and chronic myocarditis
    Hinojar, R.
    Foote, L.
    Ucar, E. Arroyo
    Dabir, D.
    Schnackenburg, B.
    Higgins, D.
    Schaeffter, T.
    Nagel, E.
    Puntmann, V.
    EUROPEAN HEART JOURNAL, 2014, 35 : 120 - 120