Custom Copings for Accurate Impressions of Multiple Internal Connection Implants

被引:1
|
作者
Ntounis, Athanasios [1 ]
Pelekanos, Stauros [1 ]
机构
[1] Athens Dent Sch, Dept Prosthodont, Athens, Greece
关键词
implants; internal connection; impression; copings; DENTAL IMPLANTS; PROSTHODONTICS; ANGULATIONS;
D O I
10.1097/ID.0b013e3181ecff52
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The technique presented facilitates a 1-step final impression and registration of multiple internal connection implants that have an unfavorable proximity. This is achieved by the use of customized impression elements that provide an accurate registration of the implant positions and the maxillomandibular relation. By means of this procedure, problematic implant positions are bypassed and chair-side time is reduced significantly. (Implant Dent 2010; 19: 365-369)
引用
收藏
页码:365 / 369
页数:5
相关论文
共 50 条
  • [21] Trueness and precision of 5 intraoral scanners in the impressions of single and multiple implants: a comparative in vitro study
    Francesco Guido Mangano
    Uli Hauschild
    Giovanni Veronesi
    Mario Imburgia
    Carlo Mangano
    Oleg Admakin
    BMC Oral Health, 19
  • [22] Trueness and precision of 5 intraoral scanners in the impressions of single and multiple implants: a comparative in vitro study
    Mangano, Francesco Guido
    Hauschild, Uli
    Veronesi, Giovanni
    Imburgia, Mario
    Mangano, Carlo
    Admakin, Oleg
    BMC ORAL HEALTH, 2019, 19 (1)
  • [23] An evaluation of impression techniques for multiple internal connection implant prostheses
    Vigolo, P
    Fonzi, F
    Majzoub, Z
    Cordioli, G
    JOURNAL OF PROSTHETIC DENTISTRY, 2004, 92 (05): : 470 - 476
  • [24] Correlation Between Interimplant Distance and Crestal Bone Loss in Internal Connection Implants with Platform Switching
    Jo, Deuk-Won
    Yi, Yang-Jin
    Kwon, Min-Jung
    Kim, Young-Kyun
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (02) : 296 - 302
  • [25] Multiple neurotic skin gangrene and its connection with internal secretion.
    Sklarz, E
    ARCHIV FUR DERMATOLOGIE UND SYPHILIS, 1921, 132 : 238 - 249
  • [26] An In Vitro Comparison of Fracture Load of Zirconia Custom Abutments with Internal Connection and Different Angulations and Thickness: Part I
    Albosefi, Abdalah
    Finkelman, Matthew
    Zandparsa, Roya
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2014, 23 (04): : 296 - 301
  • [27] An In Vitro Comparison of Fracture Load of Zirconia Custom Abutments with Internal Connection and Different Angulations and Thicknesses: Part II
    Zandparsa, Roya
    Albosefi, Abdalah
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2016, 25 (02): : 151 - 155
  • [28] Marginal Bone Loss in Implants with External Connection versus Internal Conical Connection Prior to Prosthetic Loading. A Randomized Clinical Study
    Palacios-Garzon, Natalia
    Ayuso-Montero, Raul
    Jane-Salas, Enric
    Anglada-Cantarell, Jose Maria
    Lopez-Lopez, Jose
    COATINGS, 2020, 10 (11) : 1 - 17
  • [29] Accuracy of impressions and casts using different implant impression techniques in a multi-implant system with an internal hex connection
    Wenz, Hans-Juergen
    Hertrampf, Katrin
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2008, 23 (01) : 39 - 47
  • [30] Accurate Diagnosis of Cell Internal Defects with Multiple Excitation and Propagation Conditions
    Kathpalia, Sonam
    Chillarige, Sameer
    Nandakumar, Bharath
    Madhur
    Malagi, Santosh
    2022 IEEE INTERNATIONAL TEST CONFERENCE INDIA (ITC INDIA), 2022,