Comparison of Hydrus and iStent microinvasive glaucoma surgery implants in combination with phacoemulsification for treatment of open-angle glaucoma: systematic review and network meta-analysis

被引:11
|
作者
Hu, Rongrong [1 ]
Guo, Dongyu [1 ]
Hong, Nan [1 ]
Xuan, Xiuyuan [1 ]
Wang, Xiaoyu [1 ]
机构
[1] Zhejiang Univ, Dept Ophthalmol, Affiliated Hosp 1, Sch Med, Hangzhou, Zhejiang, Peoples R China
来源
BMJ OPEN | 2022年 / 12卷 / 06期
基金
中国国家自然科学基金;
关键词
Glaucoma; Cataract and refractive surgery; Ophthalmology; TRABECULAR BYPASS STENTS; MINIMALLY INVASIVE GLAUCOMA; INTRAOCULAR-PRESSURE; OUTFLOW FACILITY; CATARACT-SURGERY; MICROBYPASS STENT; QUALITY; RELIABILITY; TRIALS;
D O I
10.1136/bmjopen-2021-051496
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives To compare the efficacy and safety of two Schlemm's canal-based microinvasive glaucoma surgery (MIGS) devices, the Hydrus Microstent and the iStent Trabecular Bypass combined with phacoemulsification for treatment of open-angle glaucoma. Design Systematic review and network meta-analysis. Methods Literature searches were conducted on PubMed, Web of Science, Cochrane Library and ClinicalTrials.gov to identify randomised controlled trials (RCTs) assessing the Hydrus or the iStent implantation combined with phacoemulsification for treatment of open-angle glaucoma until September 2020. Risk of bias was assessed using a six-item modified Jadad scale. Effects were estimated using the intraocular pressure (IOP) reduction (IOPR), the percentage of IOPR and the proportion of medication-free patients at follow-up end. Safety was estimated using the proportions of adverse events. The network meta-analysis was conducted within a Bayesian framework using the Markov Chain Monte Carlo method in ADDIS software. Results Six prospective RCTs comprising 1397 patients were identified. Regarding the absolute value and the percentage of IOPR, the Hydrus and 2-iStent implantation combined with phacoemulsification were significantly more effective than phacoemulsification alone. Rank probability analysis revealed the Hydrus might be the best choice to lower IOP. There was no significant difference in the proportion of medication-free patients among groups. The Hydrus and 2-iStent implantation had a higher probability to achieve the medication-free status versus the 1-iStent implantation and phacoemulsification alone. Overall safety profiles were good for each device with the focal peripheral anterior synechiae more frequently reported in Hydrus eyes. Conclusions The Hydrus implantation may have a slight advantage over the 1-iStent or 2-iStent implantation in combination with phacoemulsification to treat open-angle glaucoma. Our findings might be of some uncertainty due to the limited included data. Further studies are needed to investigate whether our findings are robust, including high-quality RCTs to directly compare these MIGS devices.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Primary open-angle glaucoma and its relationship with smoking: A systematic review and meta-analysis
    Ramji, Saajan
    Daniel, Sohail
    Kailani, Obeda
    ACTA OPHTHALMOLOGICA, 2024, 102
  • [32] Diabetes Mellitus as a Risk Factor for Open-Angle Glaucoma: A Systematic Review and Meta-Analysis
    Zhou, Minwen
    Wang, Wei
    Huang, Wenbin
    Zhang, Xiulan
    PLOS ONE, 2014, 9 (08):
  • [33] Ocular Perfusion Pressure and the Risk of Open-Angle Glaucoma: Systematic Review and Meta-analysis
    Ko Eun Kim
    Sohee Oh
    Sung Uk Baek
    Seong Joon Ahn
    Ki Ho Park
    Jin Wook Jeoung
    Scientific Reports, 10
  • [34] Efficacy and tolerability of nonpenetrating glaucoma surgery augmented with mitomycin C in treatment of open-angle glaucoma: a meta-analysis
    Cheng, Jin-Wei
    Xi, Gui-Lin
    Wei, Rui-Li
    Cai, Ji-Ping
    Li, You
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2009, 44 (01): : 76 - 82
  • [35] Comparison of Outcomes of iStent with Cataract Surgery versus Cataract Surgery Alone in Open-Angle Glaucoma
    Miller, Mia
    Hughes, Bret
    Apple, Joshua
    Kim, Chaesik
    Tannir, Justin
    Goyal, Anju
    Shukairy, Aman
    Kim, Chaesik
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [36] Efficacy and Tolerability of Nonpenetrating Filtering Surgery in the Treatment of Open-Angle Glaucoma: A Meta-Analysis
    Cheng, Jin-Wei
    Xi, Gui-Lin
    Wei, Rui-Li
    Cai, Ji-Ping
    Li, You
    OPHTHALMOLOGICA, 2010, 224 (03) : 138 - 146
  • [37] Minimally Invasive Glaucoma Surgical Techniques for Open-Angle Glaucoma An Overview of Cochrane Systematic Reviews and Network Meta-analysis
    Bicket, Amanda K.
    Le, Jimmy T.
    Azuara-Blanco, Augusto
    Gazzard, Gus
    Wormald, Richard
    Bunce, Catey
    Hu, Kuang
    Jayaram, Hari
    King, Anthony
    Otarola, Francisco
    Nikita, Eleni
    Shah, Anupa
    Stead, Richard
    Toth, Marta
    Li, Tianjing
    JAMA OPHTHALMOLOGY, 2021, 139 (09) : 983 - 989
  • [38] Penetrance of MYOC gene mutation in primary open-angle glaucoma: A systematic review and meta-analysis
    Xie, Juan-Juan
    Zhang, Guo-Wei
    Cui, Hai-Yue
    Li, Na
    Liu, Xing-Xing
    Hao, Meng-Yao
    Wang, Shao-Wen
    Lu, Hong
    OPHTHALMIC GENETICS, 2022, 43 (02) : 240 - 247
  • [39] Associations of statin use with the onset and progression of open-angle glaucoma: A systematic review and meta-analysis
    Yuan, Yixiong
    Xiong, Ruilin
    Wu, Yi
    Ha, Jason
    Wang, Wei
    Han, Xiaotong
    He, Mingguang
    ECLINICALMEDICINE, 2022, 46
  • [40] Relationship between Diabetic Retinopathy and Primary Open-Angle Glaucoma: A Systematic Review and Meta-Analysis
    Kjaersgaard, Marianne
    Grauslund, Jakob
    Vestergaard, Anders Hojslet
    Subhi, Yousif
    OPHTHALMIC RESEARCH, 2022, 65 (04) : 377 - 386