Comparison of Hydrus and iStent microinvasive glaucoma surgery implants in combination with phacoemulsification for treatment of open-angle glaucoma: systematic review and network meta-analysis

被引:11
|
作者
Hu, Rongrong [1 ]
Guo, Dongyu [1 ]
Hong, Nan [1 ]
Xuan, Xiuyuan [1 ]
Wang, Xiaoyu [1 ]
机构
[1] Zhejiang Univ, Dept Ophthalmol, Affiliated Hosp 1, Sch Med, Hangzhou, Zhejiang, Peoples R China
来源
BMJ OPEN | 2022年 / 12卷 / 06期
基金
中国国家自然科学基金;
关键词
Glaucoma; Cataract and refractive surgery; Ophthalmology; TRABECULAR BYPASS STENTS; MINIMALLY INVASIVE GLAUCOMA; INTRAOCULAR-PRESSURE; OUTFLOW FACILITY; CATARACT-SURGERY; MICROBYPASS STENT; QUALITY; RELIABILITY; TRIALS;
D O I
10.1136/bmjopen-2021-051496
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives To compare the efficacy and safety of two Schlemm's canal-based microinvasive glaucoma surgery (MIGS) devices, the Hydrus Microstent and the iStent Trabecular Bypass combined with phacoemulsification for treatment of open-angle glaucoma. Design Systematic review and network meta-analysis. Methods Literature searches were conducted on PubMed, Web of Science, Cochrane Library and ClinicalTrials.gov to identify randomised controlled trials (RCTs) assessing the Hydrus or the iStent implantation combined with phacoemulsification for treatment of open-angle glaucoma until September 2020. Risk of bias was assessed using a six-item modified Jadad scale. Effects were estimated using the intraocular pressure (IOP) reduction (IOPR), the percentage of IOPR and the proportion of medication-free patients at follow-up end. Safety was estimated using the proportions of adverse events. The network meta-analysis was conducted within a Bayesian framework using the Markov Chain Monte Carlo method in ADDIS software. Results Six prospective RCTs comprising 1397 patients were identified. Regarding the absolute value and the percentage of IOPR, the Hydrus and 2-iStent implantation combined with phacoemulsification were significantly more effective than phacoemulsification alone. Rank probability analysis revealed the Hydrus might be the best choice to lower IOP. There was no significant difference in the proportion of medication-free patients among groups. The Hydrus and 2-iStent implantation had a higher probability to achieve the medication-free status versus the 1-iStent implantation and phacoemulsification alone. Overall safety profiles were good for each device with the focal peripheral anterior synechiae more frequently reported in Hydrus eyes. Conclusions The Hydrus implantation may have a slight advantage over the 1-iStent or 2-iStent implantation in combination with phacoemulsification to treat open-angle glaucoma. Our findings might be of some uncertainty due to the limited included data. Further studies are needed to investigate whether our findings are robust, including high-quality RCTs to directly compare these MIGS devices.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Effects of Travoprost in the Treatment of Open-Angle Glaucoma or Ocular Hypertension: A Systematic Review and Meta-Analysis
    Cheng, Jin-Wei
    Xi, Gui-Lin
    Wei, Rui-Li
    Cai, Ji-Ping
    Li, You
    CURRENT THERAPEUTIC RESEARCH-CLINICAL AND EXPERIMENTAL, 2009, 70 (04): : 335 - 350
  • [22] Comparison of Outcomes of Phacoemulsification Combined with Endoscopic Cyclophotocoagulation, iStent, or Both in the Management of Open-Angle Glaucoma
    Galia A. Deitz
    Jennifer L. Patnaik
    Cara E. Capitena Young
    Monica K. Ertel
    Jeffrey R. SooHoo
    Leonard K. Seibold
    Malik Y. Kahook
    Mina B. Pantcheva
    Advances in Therapy, 2023, 40 (4) : 1444 - 1455
  • [23] Comparison of Outcomes of Phacoemulsification Combined with Endoscopic Cyclophotocoagulation, iStent, or Both in the Management of Open-Angle Glaucoma
    Deitz, Galia A.
    Patnaik, Jennifer L.
    Young, Cara E. Capitena
    Ertel, Monica K.
    SooHoo, Jeffrey R.
    Seibold, Leonard K.
    Kahook, Malik Y.
    Pantcheva, Mina B.
    ADVANCES IN THERAPY, 2023, 40 (04) : 1444 - 1455
  • [24] Associations of different types of statins with the risk of open-angle glaucoma: a systematic review and network meta-analysis
    Pan, Ssu-Yu
    Chen, Yun-Yu
    Hsu, Min-Yen
    Sheen, Yi-Jing
    Weng, Chien-Hsiang
    Lu, Yi-An
    Wang, I-Jong
    Wu, Mei-Hua
    Chou, Chien-Chih
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2025, 263 (01) : 201 - 208
  • [25] Comparison of the iStent Inject® versus the iStent Inject® W-Both in Combination with Cataract Surgery-In Open-Angle Glaucoma
    Deneri, Steffen
    Merte, Ralph-Laurent
    Eter, Nicole
    Bruecher, Viktoria C.
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (23)
  • [26] Role of hypertension as a risk factor for open-angle glaucoma: a systematic review and meta-analysis
    Nislawati, Ririn
    Taufik Fadillah Zainal, Ahmad
    Ismail, Abrar
    Waspodo, Noro
    Kasim, Firdaus
    Gunawan, Andi Muh Aunul Khaliq
    BMJ OPEN OPHTHALMOLOGY, 2021, 6 (01):
  • [27] The Effect of Phacoemulsification on the Intraocular Pressure of Patients With Open Angle Glaucoma: A Systematic Review and Meta-Analysis
    Benekos, Konstantinos
    Katsanos, Andreas
    Haidich, Anna-Bettina
    Dastiridou, Anna
    Nikolaidou, Anna
    Konstas, Anastasios G.
    JOURNAL OF GLAUCOMA, 2024, 33 (08) : 576 - 586
  • [28] Systematic review and meta-analysis on the efficacy of selective laser trabeculoplasty in open-angle glaucoma
    Wong, Mandy Oi Man
    Lee, Jacky Wai Yip
    Choy, Bonnie Nga Kwan
    Chan, Jonathan Cheuk Hung
    Lai, Jimmy Shiu Ming
    SURVEY OF OPHTHALMOLOGY, 2015, 60 (01) : 36 - 50
  • [29] The Association between Myopia and Primary Open-Angle Glaucoma: A Systematic Review and Meta-Analysis
    Wu, Jian
    Hao, Jie
    Du, Yifan
    Cao, Kai
    Lin, Caixia
    Sun, Runzhou
    Xie, Yuan
    Wang, Ningli
    OPHTHALMIC RESEARCH, 2022, 65 (04) : 387 - 397
  • [30] Ocular Perfusion Pressure and the Risk of Open-Angle Glaucoma: Systematic Review and Meta-analysis
    Kim, Ko Eun
    Oh, Sohee
    Baek, Sung Uk
    Ahn, Seong Joon
    Park, Ki Ho
    Jeoung, Jin Wook