Comparison of Hydrus and iStent microinvasive glaucoma surgery implants in combination with phacoemulsification for treatment of open-angle glaucoma: systematic review and network meta-analysis

被引:11
|
作者
Hu, Rongrong [1 ]
Guo, Dongyu [1 ]
Hong, Nan [1 ]
Xuan, Xiuyuan [1 ]
Wang, Xiaoyu [1 ]
机构
[1] Zhejiang Univ, Dept Ophthalmol, Affiliated Hosp 1, Sch Med, Hangzhou, Zhejiang, Peoples R China
来源
BMJ OPEN | 2022年 / 12卷 / 06期
基金
中国国家自然科学基金;
关键词
Glaucoma; Cataract and refractive surgery; Ophthalmology; TRABECULAR BYPASS STENTS; MINIMALLY INVASIVE GLAUCOMA; INTRAOCULAR-PRESSURE; OUTFLOW FACILITY; CATARACT-SURGERY; MICROBYPASS STENT; QUALITY; RELIABILITY; TRIALS;
D O I
10.1136/bmjopen-2021-051496
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives To compare the efficacy and safety of two Schlemm's canal-based microinvasive glaucoma surgery (MIGS) devices, the Hydrus Microstent and the iStent Trabecular Bypass combined with phacoemulsification for treatment of open-angle glaucoma. Design Systematic review and network meta-analysis. Methods Literature searches were conducted on PubMed, Web of Science, Cochrane Library and ClinicalTrials.gov to identify randomised controlled trials (RCTs) assessing the Hydrus or the iStent implantation combined with phacoemulsification for treatment of open-angle glaucoma until September 2020. Risk of bias was assessed using a six-item modified Jadad scale. Effects were estimated using the intraocular pressure (IOP) reduction (IOPR), the percentage of IOPR and the proportion of medication-free patients at follow-up end. Safety was estimated using the proportions of adverse events. The network meta-analysis was conducted within a Bayesian framework using the Markov Chain Monte Carlo method in ADDIS software. Results Six prospective RCTs comprising 1397 patients were identified. Regarding the absolute value and the percentage of IOPR, the Hydrus and 2-iStent implantation combined with phacoemulsification were significantly more effective than phacoemulsification alone. Rank probability analysis revealed the Hydrus might be the best choice to lower IOP. There was no significant difference in the proportion of medication-free patients among groups. The Hydrus and 2-iStent implantation had a higher probability to achieve the medication-free status versus the 1-iStent implantation and phacoemulsification alone. Overall safety profiles were good for each device with the focal peripheral anterior synechiae more frequently reported in Hydrus eyes. Conclusions The Hydrus implantation may have a slight advantage over the 1-iStent or 2-iStent implantation in combination with phacoemulsification to treat open-angle glaucoma. Our findings might be of some uncertainty due to the limited included data. Further studies are needed to investigate whether our findings are robust, including high-quality RCTs to directly compare these MIGS devices.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Combined Microinvasive Glaucoma Surgery With Phacoemulsification in Open-Angle Glaucoma: A Systematic Review and Meta-analysis
    Yuan, Po hsiang
    Dorling, Marisa
    Shah, Manjool
    Panarelli, Joseph F.
    Durr, Georges m.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2025, 270 : 154 - 163
  • [2] A Prospective Randomized Trial Comparing Hydrus and iStent Microinvasive Glaucoma Surgery Implants for Standalone Treatment of Open-Angle Glaucoma The COMPARE Study
    Ahmed, Iqbal Ike K.
    Fea, Antonio
    Au, Leon
    Ang, Robert E.
    Harasymowycz, Paul
    Jampel, Henry
    Samuelson, Thomas W.
    Chang, David F.
    Rhee, Douglas J.
    OPHTHALMOLOGY, 2020, 127 (01) : 52 - 61
  • [3] Minimally invasive glaucoma surgery: comparison of Hydrus microstent with iStent inject in primary open-angle glaucoma
    Komzak, Krishna
    Allen, Penelope L.
    Toh, Tze'Yo
    BMJ OPEN OPHTHALMOLOGY, 2025, 10 (01):
  • [4] Combined phacoemulsification and microinvasive glaucoma surgery in comparison to phacoemulsification alone for open angle glaucoma
    Lee, Graham A.
    Porter, Ashley J.
    Vincent, Roslyn A.
    Makk, Johanna
    Vincent, Stephen J.
    EYE, 2020, 34 (02) : 312 - 318
  • [5] Combined phacoemulsification and microinvasive glaucoma surgery in comparison to phacoemulsification alone for open angle glaucoma
    Graham A. Lee
    Ashley J. Porter
    Roslyn A. Vincent
    Johanna Makk
    Stephen J. Vincent
    Eye, 2020, 34 : 312 - 318
  • [6] Infographic: clinical trial of standalone microinvasive Glaucoma surgery implants for open Angel Glaucoma: Hydrus versus iStent
    Low, Mei Ken
    Korb, Alexa
    Yap, Jason
    Munawar, Muhammad Zarnab
    Ariff, Amirah Amin
    Henein, Christin
    Mathew, Rashmi G.
    EYE, 2025, 39 (SUPPL1) : 150 - 151
  • [7] Laser Trabeculoplasty for Open-Angle Glaucoma: A Systematic Review and Network Meta-Analysis
    Zhou, Rouxi
    Sun, Yi
    Chen, Haiying
    Sha, Sha
    He, Miao
    Wang, Wei
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 229 : 301 - 313
  • [8] NETWORK META-ANALYSIS OF THE USE OF ISTENT® INJECT MICROINVASIVE SURGERY IN COMBINATION WITH PHACOEMUSIFICATION FOR GLAUCOMA AND CATARACT PATIENTS
    Valls, M.
    Gay, J. G.
    Falvey, H.
    Cantu, M.
    Madrigal, A. M.
    VALUE IN HEALTH, 2019, 22 : S679 - S679
  • [9] Choroidal Thickness and Open-Angle Glaucoma: A Meta-Analysis and Systematic Review
    Zhang, Zhengwei
    Yu, Mengxi
    Wang, Feng
    Dai, Ying
    Wu, Zhifeng
    JOURNAL OF GLAUCOMA, 2016, 25 (05) : E446 - E454
  • [10] Canaloplasty for the treatment of primary open-angle glaucoma A protocol of systematic review and meta-analysis
    Sun, Peng
    Liu, Hong-wei
    Zhou, Ping-ping
    Meng, Yan
    MEDICINE, 2020, 99 (22) : E20408