Determination of melatonin in rat pineal, plasma and retina by high-performance liquid chromatography with electrochemical detection

被引:52
|
作者
Chanut, E
Nguyen-Legros, J
Versaux-Botteri, C
Trouvin, JH
Launay, JM
机构
[1] Fac Pharm, Pharmacol Lab, F-92296 Chatenay Malabry, France
[2] INSERM, U86, Lab Neurocytol Oculaire, F-75006 Paris, France
[3] Hop Lariboisiere, Biochim Lab, F-75010 Paris, France
来源
JOURNAL OF CHROMATOGRAPHY B | 1998年 / 709卷 / 01期
关键词
rat retina; melatonin;
D O I
10.1016/S0378-4347(98)00041-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive method for the routine measurement of endogenous melatonin (MEL) in pineal, retina and plasma rat tissues has been developed using reversed-phase high-performance liquid chromatography with electrochemical detection. Quantification limit for MEL was 0.2 ng/mg protein in pineal, 15 pg/ml in plasma and 2.0 pg/mg protein in retina. To improve both MEL quantification and the reproducibility of the assay, an internal standard was used when an extraction in organic solvent was required, in contrast with other available chromatographic methods. MEL values and the circadian profile obtained in this study from both rat pineal and plasma agree with those reported previously. This method allows MEL detection in mammal retina, particularly in rat, where MEL levels are very low. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:11 / 18
页数:8
相关论文
共 50 条
  • [1] PINEAL AND PLASMA MELATONIN AS DETERMINED BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION
    VIEIRA, R
    MIGUEZ, J
    LEMA, M
    ALDEGUNDE, M
    ANALYTICAL BIOCHEMISTRY, 1992, 205 (02) : 300 - 305
  • [2] Determination of melatonin in rat plasma by high performance liquid chromatography with electrochemical detection
    Chou, ST
    Perng, TF
    JOURNAL OF FOOD AND DRUG ANALYSIS, 1997, 5 (02) : 131 - 137
  • [3] Determination of timiperone in rat plasma by high-performance liquid chromatography with electrochemical detection
    Takayasu, T
    Kakubari, I
    Fukamachi, A
    Mafune, E
    Takasugi, N
    Takayama, K
    Nagai, T
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 679 (1-2): : 161 - 165
  • [4] DETERMINATION OF MELATONIN BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION
    GOLDMAN, ME
    HAMM, H
    ERICKSON, CK
    JOURNAL OF CHROMATOGRAPHY, 1980, 190 (01): : 217 - 220
  • [5] DETERMINATION OF PINEAL MELATONIN BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION - APPLICATION FOR RHYTHM STUDIES AND TISSUE EXPLANTS
    HERNANDEZ, G
    ABREU, P
    ALONSO, R
    CALZADILLA, CH
    JOURNAL OF PINEAL RESEARCH, 1990, 8 (01) : 11 - 19
  • [6] Determination of diclofenac in plasma by high-performance liquid chromatography with electrochemical detection
    Chmielewska, A
    Konieczna, L
    Plenis, A
    Bieniecki, M
    Lamparczyk, H
    BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (01) : 119 - 124
  • [7] SIMULTANEOUS DETERMINATION OF HYDROXYINDOLES AND CATECHOLAMINES IN RAT PINEAL USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION
    TAYLOR, DA
    JOHNSON, VJ
    CRAWFORD, IL
    FEDERATION PROCEEDINGS, 1982, 41 (03) : 648 - 648
  • [8] DETERMINATION OF APOMORPHINE IN RAT PLASMA AND BRAIN BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION
    BIANCHI, G
    LANDI, M
    JOURNAL OF CHROMATOGRAPHY, 1985, 338 (01): : 230 - 235
  • [9] DETERMINATION OF BAICALIN AND BAICALEIN IN RAT PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION
    WAKUI, Y
    YANAGISAWA, E
    ISHIBASHI, E
    MATSUZAKI, Y
    TAKEDA, S
    SASAKI, H
    ABURADA, M
    OYAMA, T
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 575 (01): : 131 - 136
  • [10] Determination of α-tocopherol and α-tocopherylquinone in rat tissues and plasma by high-performance liquid chromatography with electrochemical detection
    Kanazawa, H
    Miyata, C
    Nagata, Y
    Urano, S
    Matsushima, Y
    CHEMICAL & PHARMACEUTICAL BULLETIN, 2000, 48 (10) : 1462 - 1466