Determination of melatonin in rat pineal, plasma and retina by high-performance liquid chromatography with electrochemical detection

被引:52
|
作者
Chanut, E
Nguyen-Legros, J
Versaux-Botteri, C
Trouvin, JH
Launay, JM
机构
[1] Fac Pharm, Pharmacol Lab, F-92296 Chatenay Malabry, France
[2] INSERM, U86, Lab Neurocytol Oculaire, F-75006 Paris, France
[3] Hop Lariboisiere, Biochim Lab, F-75010 Paris, France
来源
JOURNAL OF CHROMATOGRAPHY B | 1998年 / 709卷 / 01期
关键词
rat retina; melatonin;
D O I
10.1016/S0378-4347(98)00041-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive method for the routine measurement of endogenous melatonin (MEL) in pineal, retina and plasma rat tissues has been developed using reversed-phase high-performance liquid chromatography with electrochemical detection. Quantification limit for MEL was 0.2 ng/mg protein in pineal, 15 pg/ml in plasma and 2.0 pg/mg protein in retina. To improve both MEL quantification and the reproducibility of the assay, an internal standard was used when an extraction in organic solvent was required, in contrast with other available chromatographic methods. MEL values and the circadian profile obtained in this study from both rat pineal and plasma agree with those reported previously. This method allows MEL detection in mammal retina, particularly in rat, where MEL levels are very low. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:11 / 18
页数:8
相关论文
共 50 条
  • [31] DETERMINATION OF ISOXSUPRINE IN EQUINE PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION
    HASHEM, A
    LUBCZYK, B
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 563 (01): : 216 - 223
  • [32] Determination of plasma free fatty acids by high-performance liquid chromatography with electrochemical detection
    Kotani, A
    Fuse, T
    Kusu, F
    ANALYTICAL BIOCHEMISTRY, 2000, 284 (01) : 65 - 69
  • [33] DETERMINATION OF PLASMA MEPINDOLOL LEVELS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND ELECTROCHEMICAL DETECTION
    KRAUSE, W
    JOURNAL OF CHROMATOGRAPHY, 1980, 181 (01): : 67 - 75
  • [34] DETERMINATION OF PSILOCIN IN RAT URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION
    KYSILKA, R
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 534 : 287 - 290
  • [35] Simultaneous determination of serotonin, N-acetylserotonin and melatonin in the pineal gland of the juvenile golden hamster by high-performance liquid chromatography with electrochemical detection
    Harumi, T
    Akutsu, H
    Matsushima, S
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 675 (01): : 152 - 156
  • [36] CONCURRENT ONLINE SAMPLING OF MELATONIN IN PINEAL MICRODIALYSATES FROM CONSCIOUS RAT AND ITS ANALYSIS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION
    AZEKAWA, T
    SANO, A
    AOI, K
    SEI, H
    MORITA, Y
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 530 (01): : 47 - 55
  • [37] Determination of apigenin in rat plasma by high-performance liquid chromatography
    Romanová, D
    Grancai, D
    Józová, B
    Bozek, P
    Vachálková, A
    JOURNAL OF CHROMATOGRAPHY A, 2000, 870 (1-2) : 463 - 467
  • [38] Determination of sinefungin in rat plasma by high-performance liquid chromatography
    TharasseBloch, C
    Brasseur, P
    Favennec, L
    Marchand, J
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1995, 674 (02): : 247 - 252
  • [39] Determination of bergenin in rat plasma by high-performance liquid chromatography
    Qin, Xuan
    Zhou, Dan
    Zhang, Zhi-Rong
    Huang, Yuan
    PHARMAZIE, 2007, 62 (05): : 323 - 326
  • [40] Determination of serotonin, melatonin and metabolites in gastrointestinal tissue using high-performance liquid chromatography with electrochemical detection
    Chau, Rosanna M. W.
    Patel, Bhavik Anil
    BIOMEDICAL CHROMATOGRAPHY, 2009, 23 (02) : 175 - 181