Estimation of Energy Saving in Educational Building from Daylighting to Improve the Visual Comfort

被引:1
|
作者
Noshin, Sadaf [1 ]
Alamgir, Sabahat [2 ]
Khan, Muhammad Arif [3 ]
机构
[1] Univ Lahore, Dept Civil Technol, Lahore, Pakistan
[2] Univ Engn & Technol, Dept Prod & Ind Design, Lahore, Pakistan
[3] Univ Engn & Technol, Dept Architectural Engn & Design, Lahore, Pakistan
关键词
Daylighting; Lighting Load; Illuminance; Artificial Luminaries; Energy Efficient; Lumen Method; Energy Consumption; PERFORMANCE; CLASSROOMS;
D O I
10.22581/muet1982.1904.19
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Daylight is the occupied-range of light that is appropriate to the human visual response. Thus, it can contribute to human health, performance and productivity. Energy consumption can be reduced by improving in energy efficiency. The study emphaseson the design of lighting system that will be energy efficient. The basic purpose of this paper describes how to reduce the mounted lighting load and improve the illumination level as per international standards. A good lighting scheme should be based on more energy efficient & longer life and maintenance free equipment. In this research paper,a hypothetical study space is selected for the daylight analysis on the Ecotect and the Radiance software on summer solstice and winter solstice days under over cast sky condition. Ecotect software is used to determine lighting demand inside the selected study space and the obtained data is exported on Radiance for detailed and more accurate daylight analysis. It is pragmatic that illuminance level is varied with respect to date and time that are clearly expressed by the daily sun path and shadow range. It is also perceived that the installed artificial luminaries does not provide the required illuminance on the working plane and consume more energy. The major aim of this research is to reduce the lighting load by introducing energy efficient artificial luminaries into the room that provide the required illuminance level on the working plane. Lumen method is used to explain the energy saving which is carried out according to existing energy consumption compared with the proposed one. At the end cost comparison of energy consumption and payback period is alsocalculated. This study shows that overall cost saving in energy consumption is approximately 34.37% and the calculated payback period for the newly installed lights is comprising of approximately 11 months.
引用
收藏
页码:1077 / 1086
页数:10
相关论文
共 50 条
  • [31] Enthalpy estimation for thermal comfort and energy saving in air conditioning system
    Chu, Chi-Min
    Jong, Tai-Lang
    ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (06) : 1620 - 1628
  • [32] Model for Thermal Comfort and Energy Saving Based on Individual Sensation Estimation
    Lopez, Guillaume
    Aoki, Takuya
    Nkurikiyeyezu, Kizito
    Yokokubo, Anna
    SENSORS AND MATERIALS, 2020, 32 (02) : 693 - 702
  • [33] The Human Comfort Level in an Energy-Saving Simulation Model of Office Building
    Dzelzitis, Egils
    Sidenko, Sandra
    12TH NORDIC SYMPOSIUM ON BUILDING PHYSICS (NSB 2020), 2020, 172
  • [34] A Review of Transparent Insulation Material (TIM) for building energy saving and daylight comfort
    Sun, Yanyi
    Wilson, Robin
    Wu, Yupeng
    APPLIED ENERGY, 2018, 226 : 713 - 729
  • [35] Building automation: Photovoltaic assisted thermal comfort management system for energy saving
    Khan, M. Reyasudin Basir
    Jidin, Razali
    Pasupuleti, Jagadeesh
    Shaaya, Sharifah Azwa
    4TH INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENT 2013 (ICEE 2013), 2013, 16
  • [36] Energy saving potential and visual comfort of task light usage for offices in Malaysia
    Gene-Harn, Lim
    Keumala, Nila
    Ab Ghafar, Norafida
    ENERGY AND BUILDINGS, 2017, 147 : 166 - 175
  • [37] The energy saving and indoor comfort improvements with latent thermal energy storage in building retrofits in Canada
    Berardi, Umberto
    Manca, Mauro
    8TH INTERNATIONAL CONFERENCE ON SUSTAINABILITY IN ENERGY AND BUILDINGS, SEB-16, 2017, 111 : 472 - 481
  • [38] Integration of completely passive cooling and heating systems with daylighting function into courtyard building towards energy saving
    Chi, Fang'ai
    Xu, Liming
    Peng, Changhai
    APPLIED ENERGY, 2020, 266
  • [39] Lighting energy savings potential of split-pane electrochromic windows controlled for daylighting with visual comfort
    Fernandes, L. L.
    Lee, E. S.
    Ward, G.
    ENERGY AND BUILDINGS, 2013, 61 : 8 - 20
  • [40] Smart Electrochromic Windows to Enhance Building Energy Efficiency and Visual Comfort
    Cannavale, Alessandro
    Ayr, Ubaldo
    Fiorito, Francesco
    Martellotta, Francesco
    ENERGIES, 2020, 13 (06)