Estimation of Energy Saving in Educational Building from Daylighting to Improve the Visual Comfort

被引:1
|
作者
Noshin, Sadaf [1 ]
Alamgir, Sabahat [2 ]
Khan, Muhammad Arif [3 ]
机构
[1] Univ Lahore, Dept Civil Technol, Lahore, Pakistan
[2] Univ Engn & Technol, Dept Prod & Ind Design, Lahore, Pakistan
[3] Univ Engn & Technol, Dept Architectural Engn & Design, Lahore, Pakistan
关键词
Daylighting; Lighting Load; Illuminance; Artificial Luminaries; Energy Efficient; Lumen Method; Energy Consumption; PERFORMANCE; CLASSROOMS;
D O I
10.22581/muet1982.1904.19
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Daylight is the occupied-range of light that is appropriate to the human visual response. Thus, it can contribute to human health, performance and productivity. Energy consumption can be reduced by improving in energy efficiency. The study emphaseson the design of lighting system that will be energy efficient. The basic purpose of this paper describes how to reduce the mounted lighting load and improve the illumination level as per international standards. A good lighting scheme should be based on more energy efficient & longer life and maintenance free equipment. In this research paper,a hypothetical study space is selected for the daylight analysis on the Ecotect and the Radiance software on summer solstice and winter solstice days under over cast sky condition. Ecotect software is used to determine lighting demand inside the selected study space and the obtained data is exported on Radiance for detailed and more accurate daylight analysis. It is pragmatic that illuminance level is varied with respect to date and time that are clearly expressed by the daily sun path and shadow range. It is also perceived that the installed artificial luminaries does not provide the required illuminance on the working plane and consume more energy. The major aim of this research is to reduce the lighting load by introducing energy efficient artificial luminaries into the room that provide the required illuminance level on the working plane. Lumen method is used to explain the energy saving which is carried out according to existing energy consumption compared with the proposed one. At the end cost comparison of energy consumption and payback period is alsocalculated. This study shows that overall cost saving in energy consumption is approximately 34.37% and the calculated payback period for the newly installed lights is comprising of approximately 11 months.
引用
收藏
页码:1077 / 1086
页数:10
相关论文
共 50 条
  • [21] INVESTIGATION OF ENERGY SAVING PERFORMANCE AND OTHER RELATED PARAMETERS OF A DAYLIGHTING SCENARIO FOR AN INDUSTRIAL BUILDING
    Demirbas, Musa
    Cavus, Turker Fedai
    Tirmikci, Ceyda Aksoy
    Yavuz, Cenk
    LIGHT & ENGINEERING, 2017, 25 (02): : 51 - 55
  • [22] Visual Comfort Control for Building Energy Management System
    Lin, Shin-Yen
    Chen, Wei-Yuan
    RENEWABLE AND SUSTAINABLE ENERGY II, PTS 1-4, 2012, 512-515 : 2838 - +
  • [23] A Review on Adaptive Thermal Comfort of Office Building for Energy-Saving Building Design
    Lamsal, Prativa
    Bajracharya, Sushil Bahadur
    Rijal, Hom Bahadur
    ENERGIES, 2023, 16 (03)
  • [24] Comfort air-conditioning control for building energy-saving
    Yonezawa, K
    Yamada, F
    Wada, Y
    Hanada, Y
    IECON 2000: 26TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-4: 21ST CENTURY TECHNOLOGIES AND INDUSTRIAL OPPORTUNITIES, 2000, : 1737 - 1742
  • [25] Building Thermal Comfort Research Based on Energy-Saving Concept
    Xue, Feiran
    Zhao, Jingyuan
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2021, 2021
  • [26] Personal thermal management techniques for thermal comfort and building energy saving
    Ma, Z.
    Zhao, D.
    She, C.
    Yang, Y.
    Yang, R.
    MATERIALS TODAY PHYSICS, 2021, 20
  • [27] Supply Demand Coordination for Building Energy Saving: Explore the Soft Comfort
    Xu, Zhanbo
    Jia, Qing-Shan
    Guan, Xiaohong
    IEEE TRANSACTIONS ON AUTOMATION SCIENCE AND ENGINEERING, 2015, 12 (02) : 656 - 665
  • [28] Evaluation of impact of passive design measures with energy saving potential through estimation of shading control for visual comfort
    Sharma, Lakshya
    Lal, K. Kishan
    Rakshit, Dibakar
    JOURNAL OF BUILDING PHYSICS, 2018, 42 (03) : 220 - 238
  • [29] Daylighting utilization and uniformity comparison for a concentrator-photovoltaic window in energy saving application on the building
    Xuan, Qingdong
    Li, Guiqiang
    Lu, Yashun
    Zhao, Bin
    Wang, Fuqiang
    Pei, Gang
    ENERGY, 2021, 214
  • [30] Energy saving through the sun: Analysis of visual comfort and energy consumption in office space
    Tagliabue, Lavinia Chiara
    Buzzetti, Michela
    Arosio, Barbara
    1ST INTERNATIONAL CONFERENCE ON SOLAR HEATING AND COOLING FOR BUILDINGS AND INDUSTRY (SHC 2012), 2012, 30 : 693 - 703