Amperometric biogenic amine biosensors based on Prussian blue, indium tin oxide nanoparticles and diamine oxidase- or monoamine oxidase-modified electrodes

被引:34
|
作者
Kacar, Ceren [1 ]
Erden, Pinar Esra [2 ]
Dalkiran, Berna [1 ]
Inal, Emine Kubra [1 ]
Kilic, Esma [1 ]
机构
[1] Ankara Univ, Fac Sci, Dept Chem, TR-06100 Ankara, Turkey
[2] Ankara Haci Bayram Veli Univ, Polatli Fac Sci & Arts, Dept Chem, TR-06900 Ankara, Turkey
关键词
Amperometry; Biosensor; Biogenic amine; Indium tin oxide; Prussian blue; Screen-printed electrode; SCREEN-PRINTED ELECTRODES; ELECTROCHEMICAL BIOSENSOR; HYDROGEN-PEROXIDE; DISPOSABLE BIOSENSOR; GLUCOSE-OXIDASE; SENSOR; LAYER; GOLD; IMMOBILIZATION; NANOCOMPOSITE;
D O I
10.1007/s00216-020-02448-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Biogenic amine biosensors, based on screen-printed carbon electrodes (SPCE) modified with Prussian blue (PB) and indium tin oxide nanoparticles (ITONP), are reported. PB/ITONP-modified SPCE was further modified with diamine oxidase (DAO) or monoamine oxidase (MAO) enzymes to construct the biosensors. The morphology of the modified electrodes was studied by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX) and atomic force microscopy (AFM). Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used to enlighten the electrochemical properties of the modified electrodes at each step of biosensor fabrication. Electrode surface composition and experimental conditions were optimized and analytical performance characteristics of the biosensors were studied. Several biogenic amines were tested and both biosensors responded to histamine, putrescine and cadaverine. DAO/ITONP/PB/SPCE biosensor exhibited the highest response to histamine 6.0 x 10(-6)-6.9 x 10(-4) M with a sensitivity of 1.84 mu A mM(-1). On the other hand, the highest sensitivity was obtained for cadaverine with the MAO/ITONP/PB/SPCE biosensor. The analytical utility of the presented biosensors were illustrated by the determination of cadaverine and histamine in cheese sample.
引用
收藏
页码:1933 / 1946
页数:14
相关论文
共 50 条
  • [41] A Highly Sensitive Amperometric Glutamate Oxidase Microbiosensor Based on a Reduced Graphene Oxide/Prussian Blue Nanocube/Gold Nanoparticle Composite Film-Modified Pt Electrode
    Chen, Jing
    Yu, Qiwen
    Fu, Wei
    Chen, Xing
    Zhang, Quan
    Dong, Shurong
    Chen, Hang
    Zhang, Shaomin
    SENSORS, 2020, 20 (10)
  • [42] Amperometric Biosensor Based on Diamine Oxidase/Platinum Nanoparticles/Graphene/Chitosan Modified Screen-Printed Carbon Electrode for Histamine Detection
    Apetrei, Irina Mirela
    Apetrei, Constantin
    SENSORS, 2016, 16 (04):
  • [43] Development of an amperometric biosensor based on glucose oxidase immobilized through silica sol-gel film onto Prussian Blue modified electrode
    Li, T
    Yao, ZH
    Ding, L
    SENSORS AND ACTUATORS B-CHEMICAL, 2004, 101 (1-2) : 155 - 160
  • [44] Amperometric glucose biosensor based on immobilization of glucose oxidase in electropolymerized o-aminophenol film at Prussian blue-modified platinum electrode
    Pan, DW
    Chen, JH
    Nie, LH
    Tao, WY
    Yao, SZ
    ELECTROCHIMICA ACTA, 2004, 49 (05) : 795 - 801
  • [45] DISPOSABLE AMPEROMETRIC A-FETOPROTEIN IMMUNOSENSOR BASED ON THE BIOCOMPATIBLE SILK PROTEIN MEMBRANES-MODIFIED INDIUM TIN OXIDE ELECTRODES
    Li, Yan
    Cheng, Ping
    He, Juan
    Huang, Hui
    Deng, Jun
    Fang, Lichao
    Jiang, Lili
    Zheng, Junsong
    ANALYTICAL LETTERS, 2012, 45 (07) : 735 - 745
  • [46] An Amperometric Biosensor Based on Glucose Oxidase Immobilized in a Sol-Gel Polyvinyl Alcohol/Silica Hybrid Composite Film on a Prussian Blue Modified Electrode
    Zuo, Shao-Hua
    Zhao, Hong-Li
    Zhang, Ling-Fan
    Yuan, Hui-Hui
    Lan, Min-Bo
    Lawrence, Geoffrey A.
    Wei, Gang
    ADVANCED SCIENCE LETTERS, 2010, 3 (04) : 476 - 481
  • [48] Amperometric Ascorbic Acid Biosensors Based on the Oxygen and Glassy Carbon Electrodes Modified with Ascorbate Oxidase Immobilized-silk Fibroin/polyethylene Glycol Membrane
    Ratanasongtham, Pacharawan
    Shank, Lalida
    Jakmunee, Jaroon
    Watanesk, Ruangsri
    Watanesk, Surasak
    CHIANG MAI JOURNAL OF SCIENCE, 2017, 44 (04): : 1431 - 1440
  • [49] Amperometric Glucose Biosensor Based on Homopolymer-Chitosan Double Layered Glucose Oxidase Electrode Modified with Zinc Oxide Nanoparticles
    Ozyilmaz, Gul
    Ozyilmaz, Ali Tuncay
    Bayram, Esiye Irem
    Akyurekoglu, Ragibe Hulya
    ACTA CHIMICA SLOVENICA, 2019, 66 (04) : 950 - 957
  • [50] Monitoring of bovine serum albumin using ultrasensitive electrochemiluminescence biosensors based on multilayer CdTe quantum dots modified indium tin oxide electrodes
    Zhang, Meng
    Yan, Mei
    Yu, Jinghua
    Ge, Shenguang
    Wan, Fuwei
    Ge, Lei
    ANALYTICAL METHODS, 2012, 4 (02) : 460 - 466