Amperometric biogenic amine biosensors based on Prussian blue, indium tin oxide nanoparticles and diamine oxidase- or monoamine oxidase-modified electrodes

被引:34
|
作者
Kacar, Ceren [1 ]
Erden, Pinar Esra [2 ]
Dalkiran, Berna [1 ]
Inal, Emine Kubra [1 ]
Kilic, Esma [1 ]
机构
[1] Ankara Univ, Fac Sci, Dept Chem, TR-06100 Ankara, Turkey
[2] Ankara Haci Bayram Veli Univ, Polatli Fac Sci & Arts, Dept Chem, TR-06900 Ankara, Turkey
关键词
Amperometry; Biosensor; Biogenic amine; Indium tin oxide; Prussian blue; Screen-printed electrode; SCREEN-PRINTED ELECTRODES; ELECTROCHEMICAL BIOSENSOR; HYDROGEN-PEROXIDE; DISPOSABLE BIOSENSOR; GLUCOSE-OXIDASE; SENSOR; LAYER; GOLD; IMMOBILIZATION; NANOCOMPOSITE;
D O I
10.1007/s00216-020-02448-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Biogenic amine biosensors, based on screen-printed carbon electrodes (SPCE) modified with Prussian blue (PB) and indium tin oxide nanoparticles (ITONP), are reported. PB/ITONP-modified SPCE was further modified with diamine oxidase (DAO) or monoamine oxidase (MAO) enzymes to construct the biosensors. The morphology of the modified electrodes was studied by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX) and atomic force microscopy (AFM). Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used to enlighten the electrochemical properties of the modified electrodes at each step of biosensor fabrication. Electrode surface composition and experimental conditions were optimized and analytical performance characteristics of the biosensors were studied. Several biogenic amines were tested and both biosensors responded to histamine, putrescine and cadaverine. DAO/ITONP/PB/SPCE biosensor exhibited the highest response to histamine 6.0 x 10(-6)-6.9 x 10(-4) M with a sensitivity of 1.84 mu A mM(-1). On the other hand, the highest sensitivity was obtained for cadaverine with the MAO/ITONP/PB/SPCE biosensor. The analytical utility of the presented biosensors were illustrated by the determination of cadaverine and histamine in cheese sample.
引用
收藏
页码:1933 / 1946
页数:14
相关论文
共 50 条
  • [21] Amperometric choline biosensors prepared by layer-by-layer deposition of choline oxidase on the Prussian blue-modified platinum electrode
    Shi, Haibin
    Yang, Yu
    Huang, Jiadong
    Zhao, Zixia
    Xu, Xinhua
    Anzai, Jun-ichi
    Osa, Tetsuo
    Chen, Qiang
    TALANTA, 2006, 70 (04) : 852 - 858
  • [22] Prussian Blue Modified Amperometric Hg2+ Ion Biosensor Based on Glucose Oxidase Inhibition
    Virbickas, Povilas
    Ziziunaite, Gerda
    Ramanavicius, Arunas
    Valiuniene, Ausra
    ELECTROANALYSIS, 2023, 35 (04)
  • [23] Capabilities of amperometric monoamine oxidase biosensors based on screen-printed graphite electrodes modified with multiwall carbon nanotubes in the determination of some antidepressants
    Medyantseva, E. P.
    Brusnitsyn, D. V.
    Varlamova, R. M.
    Beshevets, M. A.
    Budnikov, H. C.
    Fattakhova, A. N.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (05) : 535 - 539
  • [24] Capabilities of amperometric monoamine oxidase biosensors based on screen-printed graphite electrodes modified with multiwall carbon nanotubes in the determination of some antidepressants
    E. P. Medyantseva
    D. V. Brusnitsyn
    R. M. Varlamova
    M. A. Beshevets
    H. C. Budnikov
    A. N. Fattakhova
    Journal of Analytical Chemistry, 2015, 70 : 535 - 539
  • [25] Single Printing Step Prussian Blue Bulk-Modified Transducers for Oxidase-Based Biosensors
    Vokhmyanina, Darya
    Daboss, Elena
    Sharapova, Olesya
    Mogilnikova, Mariia
    Karyakin, Arkady
    BIOSENSORS-BASEL, 2023, 13 (02):
  • [26] Determination of Antidepressants Using Monoamine Oxidase Amperometric Biosensors Based on Screen-Printed Graphite Electrodes Modified with Multi-Walled Carbon Nanotubes
    E. P. Medyantseva
    D. V. Brusnitsyn
    R. M. Varlamova
    M. A. Baibatarova
    G. K. Budnikov
    A. N. Fattakhova
    Pharmaceutical Chemistry Journal, 2014, 48 : 478 - 482
  • [27] Determination of Antidepressants Using Monoamine Oxidase Amperometric Biosensors Based on Screen-Printed Graphite Electrodes Modified with Multi-Walled Carbon Nanotubes
    Medyantseva, E. P.
    Brusnitsyn, D. V.
    Varlamova, R. M.
    Baibatarova, M. A.
    Budnikov, G. K.
    Fattakhova, A. N.
    PHARMACEUTICAL CHEMISTRY JOURNAL, 2014, 48 (07) : 478 - 482
  • [28] Cholesterol biosensors based on cholesterol oxidase immobilized in a silica sol-gel matrix on a Prussian blue modified electrode
    Li, Jian-Ping
    Peng, Tu-Zhi
    Gaodeng Xuexiao Huaxue Xuebao/Chemical Journal of Chinese Universities, 2003, 24 (05):
  • [29] Cholesterol biosensors based on cholesterol oxidase immobilized in a silica sol-gel matrix on a Prussian Blue modified electrode
    Li, JP
    Peng, TZ
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2003, 24 (05): : 798 - 802
  • [30] Amperometric biosensors based on carbon paste electrodes modified with nanostructured mixed-valence manganese oxides and glucose oxidase
    Cui, Xiaoli
    Liu, Guodong
    Lin, Yuehe
    NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE, 2005, 1 (02) : 130 - 135