Fire safety of facades - Recent large scale tests

被引:0
|
作者
Hakkarainen, T [1 ]
Mikkola, E [1 ]
机构
[1] VTT Bldg Technol, Fire Technol, Espoo, Finland
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The fire behaviour of wooden facades in multi-storey wood-framed houses has been studied in a Nordic research project on the fire safety of wood (Brandsakra Trahus). Two different fire scenarios were assumed: a relatively small ignition source outside a sprinklered building and flashover of a compartment fire in an unsprinklered building. Fire tests of wooden facades with different materials, surface treatments and structures were performed on intermediate and large scales. In the case of an external fire, the most efficient way to stop the propagation of flames was the structural modification of the facade profile. Fire retardant treatment delayed considerably or even stopped the fire spreading. On the basis of the test results of the flashover scenario, the use of wood in the facades of unsprinklered multi-storey houses should be limited to 20 - 50% of the total facade area, depending on the location of the wood material. In sprinklered houses, however, wood can be used more extensively. Simple criteria based on heat flux levels to windows of the facade and falling pieces have been proposed for sprinklered and unsprinklered houses to estimate the fire safety of wood products in facades of multi-storey houses.
引用
下载
收藏
页码:139 / 150
页数:12
相关论文
共 50 条
  • [41] Fire tests spark safety fears
    Hamer, M
    NEW SCIENTIST, 2002, 175 (2357) : 6 - 6
  • [42] HAMBURG OFFICES - FIRE SAFETY TESTS
    PARNELL, A
    RIBA JOURNAL-ROYAL INSTITUTE OF BRITISH ARCHITECTS, 1977, 84 (01): : 33 - 34
  • [43] Reduced-scale Model Tests of Fires in Railway Tunnel and Structure Fire Safety
    Zhao, HongLi
    Xu, ZhiSheng
    Jiang, XuePeng
    ADVANCES IN BUILDING MATERIALS, PTS 1-3, 2011, 168-170 : 2473 - 2476
  • [44] Underground concrete frame structures subjected to fire loading: Part I - Large-scale fire tests
    Ring, T.
    Zeiml, M.
    Lackner, R.
    ENGINEERING STRUCTURES, 2014, 58 : 175 - 187
  • [45] Model scale railcar fire tests
    Ingason, Haukur
    FIRE SAFETY JOURNAL, 2007, 42 (04) : 271 - 282
  • [46] FULL SCALE EXPERIMENTS AND FIRE TESTS
    WILLIAMSON, RB
    FIRELINE, 1978, 5 (01): : 16 - 16
  • [48] Fire resistance evaluation of a train carbody made of composite material by large scale tests
    Kim, Jung-Seok
    Jeong, Jong-Cheol
    Cho, Se Hyun
    Seo, Sung-Il
    COMPOSITE STRUCTURES, 2008, 83 (03) : 295 - 303
  • [49] Analysis of combustion gases from large-scale electric vehicle fire tests
    Hynynen, Jonna
    Willstrand, Ola
    Blomqvist, Per
    Andersson, Petra
    FIRE SAFETY JOURNAL, 2023, 139
  • [50] Large scale fire tests with different railway overhead systems - experience by the test center
    Seirer, Sven J.
    Wetzig, Volker
    UNDERGROUND SPACE - THE 4TH DIMENSION OF METROPOLISES, VOLS 1-3, 2007, : 1793 - 1797