摘要
The fire behaviour of wooden facades in multi-storey wood-framed houses has been studied in a Nordic research project on the fire safety of wood (Brandsakra Trahus). Two different fire scenarios were assumed: a relatively small ignition source outside a sprinklered building and flashover of a compartment fire in an unsprinklered building. Fire tests of wooden facades with different materials, surface treatments and structures were performed on intermediate and large scales. In the case of an external fire, the most efficient way to stop the propagation of flames was the structural modification of the facade profile. Fire retardant treatment delayed considerably or even stopped the fire spreading. On the basis of the test results of the flashover scenario, the use of wood in the facades of unsprinklered multi-storey houses should be limited to 20 - 50% of the total facade area, depending on the location of the wood material. In sprinklered houses, however, wood can be used more extensively. Simple criteria based on heat flux levels to windows of the facade and falling pieces have been proposed for sprinklered and unsprinklered houses to estimate the fire safety of wood products in facades of multi-storey houses.
引用
下载
收藏
页码:139 / 150
页数:12
相关论文
共 50 条
  • [21] FIRE AND UPHOLSTERED FURNITURE - SMALL VERSUS LARGE-SCALE TESTS
    PAUL, KT
    FIRE AND MATERIALS, 1986, 10 (01) : 29 - 39
  • [22] Pulsations during large-scale fire tests in the Runehamar tunnel
    Lönnermark, A
    Persson, B
    Ingason, H
    FIRE SAFETY JOURNAL, 2006, 41 (05) : 377 - 389
  • [23] Large-Scale Fire Tests on Sliding Doors for Building Applications
    Thanasoulas, Ilias
    Lauridsen, Dan
    Husted, Bjarne
    Giuliani, Luisa
    FIRE TECHNOLOGY, 2022, 58 (04) : 2357 - 2375
  • [24] Defining the effects of ambient conditions in large-scale fire tests
    Tamanini, Francesco
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2010, 34 (03) : 404 - 411
  • [25] Large-Scale Fire Tests on Sliding Doors for Building Applications
    Ilias Thanasoulas
    Dan Lauridsen
    Bjarne Husted
    Luisa Giuliani
    Fire Technology, 2022, 58 : 2357 - 2375
  • [26] Design of large-scale wooden facades
    Heikkilä, J
    1ST INTERNATIONAL RILEM SYMPOSIUM ON TIMBER ENGINEERING, 1999, 8 : 411 - 419
  • [27] OUTCOMES OF THREE LARGE SCALE FIRE REFERENCE TESTS CONDUCTED IN BAM FIRE TEST FACILITY
    Feldkamp, Martin
    Quercetti, Thomas
    Wille, Frank
    PROCEEDINGS OF THE ASME 2020 PRESSURE VESSELS & PIPING CONFERENCE (PVP2020), VOL 8, 2020,
  • [28] Large-scale Fire Tests confirm Mineral Wool Boards 035 as a Fire Bolt
    Mrozewski, Sonja
    BAUPHYSIK, 2016, 38 (05) : 334 - 334
  • [29] Fire '94 - fire safety in large-scale single-storey retail premises
    Reid, Gerry
    Todd, Colin
    Fire Prevention, 1994,
  • [30] Large compartment fire tests
    Lennon, T
    FIRE, STATIC AND DYNAMIC TESTS OF BUILDING STRUCTURES, 1997, : 45 - 53