Shock Due to an Obstructed Endotracheal Tube

被引:1
|
作者
Chua, Stefanie Foong Ling [1 ]
Chan, Chi Ho [1 ]
Thangavelautham, Suhitharan [1 ]
机构
[1] Singapore Gen Hosp, Singapore, Singapore
来源
JOURNAL OF CRITICAL CARE MEDICINE | 2021年 / 7卷 / 04期
关键词
obstruction; endotracheal tube; mucus plug; bronchoscopy; ball-valve;
D O I
10.2478/jccm-2021-0027
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Endotracheal tube obstruction by a mucus plug causing a ball-valve effect is a rare but significant complication. The inability to pass a suction catheter through the endotracheal tube with high peak and plateau pressure differences are classical features of an endotracheal tube obstruction. A case is described of endotracheal tube obstruction from a mucus plug that compounded severe respiratory acidosis and hypotension in a patient who simultaneously had abdominal compartment syndrome. The mucus plug was not identified until a bronchoscopic assessment of the airway was performed. Due to the absence of classical signs, the delayed identification of the obstructing mucus plug exacerbated diagnostic confusion. It resulted in various treatments being trialed whilst the patient continued to deteriorate from the evasive offending culprit. We suggest that earlier and more routine use of bronchoscopy should be employed in an intensive care unit, especially as a definitive way to rule out endotracheal obstruction.
引用
收藏
页码:308 / 311
页数:4
相关论文
共 50 条
  • [1] Endotracheal Tube Management and Obstructed Airway
    Sancheti, Manu
    Force, Seth
    [J]. THORACIC SURGERY CLINICS, 2015, 25 (03) : 279 - +
  • [2] OBSTRUCTED ENDOTRACHEAL TUBE DEMONSTRATED BY ROENTGENOGRAM
    THOMPSON, RC
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1956, 162 (03): : 194 - 196
  • [3] Acute Management of the Obstructed Endotracheal Tube
    Johnson, Kevin M.
    Lehman, Richard E.
    [J]. RESPIRATORY CARE, 2012, 57 (08) : 1342 - 1344
  • [4] Model-based detection of partially obstructed endotracheal tube
    Visaria, RK
    Westenskow, DR
    [J]. CRITICAL CARE MEDICINE, 2005, 33 (01) : 149 - 154
  • [5] Confusion due to endotracheal tube markings
    Sinha, Renu
    Thangaswamy, Chitra Rajeswari
    Khanna, Puneet
    Nanda, Sunil Kumar
    [J]. PEDIATRIC ANESTHESIA, 2008, 18 (12) : 1212 - 1213
  • [6] OBSTRUCTED ENDOTRACHEAL CATHETER
    SOBEL, AM
    [J]. ANESTHESIOLOGY, 1964, 25 (04) : 581 - &
  • [7] RESPIRATORY OBSTRUCTION DUE TO FAULTY ENDOTRACHEAL TUBE
    DURRANS, SF
    [J]. LANCET, 1960, 2 (NOV19): : 1145 - 1145
  • [8] RESPIRATORY OBSTRUCTION DUE TO FAULTY ENDOTRACHEAL TUBE
    MOLPHY, R
    [J]. LANCET, 1960, 2 (DEC3): : 1253 - 1253
  • [9] RESPIRATORY OBSTRUCTION DUE TO FAULTY ENDOTRACHEAL TUBE
    JOAD, M
    [J]. LANCET, 1960, 2 (OCT8): : 818 - 818
  • [10] Clearance of an obstructed endotracheal tube with an arterial embolectomy catheter with the patient in the prone position
    Grimmett, WG
    Poh, J
    [J]. ANAESTHESIA AND INTENSIVE CARE, 1998, 26 (05) : 579 - 581