A compact multi-parameter detection system based on hydrodynamic sequential injection for sensitive determination of phosphate, nitrite, and nitrate in water samples

被引:0
|
作者
Khongpet, Wanpen [1 ]
Yanu, Pattama [1 ]
Pencharee, Somkid [2 ]
Puangpila, Chanida [1 ,5 ]
Hartwell, Supaporn Kradtap [3 ]
Lapanantnoppakhun, Somchai [1 ,5 ]
Yodthongdee, Yutdanai [1 ]
Paukpol, Autchara [1 ]
Jakmunee, Jaroon [1 ,4 ,5 ]
机构
[1] Chiang Mai Univ, Fac Sci, Dept Chem, Lab Analyt Instrumentat & Electrochem Innovat, Chiang Mai 50200, Thailand
[2] Ubon Ratchathani Univ, Fac Sci, Dept Phys, Ubon Ratchathani 34190, Thailand
[3] Xavier Univ, Dept Chem, 3800 Victory Pkwy, Cincinnati, OH 45207 USA
[4] Chiang Mai Univ, Fac Sci, Environm Sci Res Ctr, Ctr Excellence Innovat Chem, Chiang Mai 50200, Thailand
[5] Chiang Mai Univ, Res Ctr Chem Dev Hlth Promoting Prod Northern Res, Fac Sci, Chiang Mai 50200, Thailand
关键词
ENVIRONMENTAL-SAMPLES; LIQUID-CHROMATOGRAPHY; REACTIVE PHOSPHATE; DEVICE; ORTHOPHOSPHATE; ANALYZER; SENSOR;
D O I
10.1039/c9ay02327e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A miniaturized microfluidic hydrodynamic sequential injection system for multi-parameter analysis with a sensitive colorimetric detection was developed to improve the analytical performance for the measurement of phosphate, nitrite, and nitrate based on molybdenum blue and Griess methods. A homemade colorimetric detection with a light emitting diode as a light source and phototransistor light sensor was integrated into the microfluidic platform to achieve a low cost compact system with low reagent consumption and high sensitivity. Under the optimized working conditions, a linear calibration graph of phosphate (two working range), nitrite and nitrate (as nitrogen, N) in the range of 0.01-0.1 and 0.3-1.0 mg of PO43- P L-1, 0.005-0.05 mg of NO2- N L-1 and 0.01-0.12 mg of NO3- N L-1, respectively were achieved with a sample-throughput of 10 h(-1). The limit of detections were 0.005 mg of PO43- P L-1, 0.0026 mg of NO2- N L-1 and 0.005 mg of NO3- N L-1. The percentage of recovery for phosphate, nitrite, and nitrate were 90.3-115.0, 90.0-117.0 and 91.3-117.0, respectively, with relative standard deviations in the range of 1.07-4.90%. Capabilities of the developed device for consecutive analysis of multiple analytes were demonstrated to be an excellent choice for water quality monitoring.
引用
收藏
页码:855 / 864
页数:10
相关论文
共 50 条
  • [41] On-site detection of nitrate plus nitrite in natural water samples using smartphone-based detection
    Fang, Tengyue
    Li, Hangqian
    Bo, Guangyong
    Lin, Kunde
    Yuan, Dongxing
    Ma, Jian
    MICROCHEMICAL JOURNAL, 2021, 165
  • [42] Flow-injection analysis method for the determination of nitrite and nitrate in natural water samples using a chemiluminescence NOx monitor
    Kanda, Y
    Taira, M
    ANALYTICAL SCIENCES, 2003, 19 (05) : 695 - 699
  • [43] Research on denoising of joint detection signal of water quality with multi-parameter based on IEEMD
    Wen Li
    Dejian Li
    Yongyue Ma
    Wang Tian
    Xin Wen
    Jie Li
    Optoelectronics Letters, 2024, 20 : 107 - 115
  • [44] A simple simultaneous flow injection method based on phosphomolybdenum chemistry for nitrate and nitrite determinations in water and fish samples
    Monser, L
    Sadok, S
    Greenway, GM
    Shah, I
    Uglow, RF
    TALANTA, 2002, 57 (03) : 511 - 518
  • [45] Design of a field flow system for the on-line spectrophotometric determination of phosphate, nitrite and nitrate in natural water and wastewater
    Tsoulfanidis, Ioannis A.
    Tsogas, George Z.
    Giokas, Dimosthenis L.
    Vlessidis, Athanasios G.
    MICROCHIMICA ACTA, 2008, 160 (04) : 461 - 469
  • [46] Design of a field flow system for the on-line spectrophotometric determination of phosphate, nitrite and nitrate in natural water and wastewater
    Ioannis A. Tsoulfanidis
    George Z. Tsogas
    Dimosthenis L. Giokas
    Athanasios G. Vlessidis
    Microchimica Acta, 2008, 160 : 461 - 469
  • [47] Water Quality Sampling and Multi-Parameter Monitoring System Based on Multi-Rotor UAV Implementation
    Zhang, Rihong
    Wang, Zhenhao
    Li, Xiaomin
    She, Zipeng
    Wang, Baoe
    WATER, 2023, 15 (11)
  • [48] The design of multi-parameter detection platform of drinking water based on two-electrode voltammetry
    Li, Ya-zhuo
    Wei, Jia-li
    Wang, Xiao-ping
    ADVANCED SENSOR SYSTEMS AND APPLICATIONS V, 2012, 8561
  • [49] Simulation study on Multi-parameter Detection method of polluted Water quality based on Sponge City
    Zhong, Wei
    Zhao, Xinfei
    2020 6TH INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY, ENVIRONMENT AND CHEMICAL ENGINEERING, PTS 1-5, 2020, 546
  • [50] SENSITIVE SPECTROPHOTOMETRIC DETERMINATION OF NITRATE-N AND NITRITE-N IN SURFACE-WATER BASED ON THE N-PHENYL-ANTHRANILIC ACID (N-PAA) NITRATE OR NITRITE SYSTEM
    QIU, XC
    ZHU, YQ
    LI, CS
    ANALUSIS, 1993, 21 (04) : 211 - 214