A compact multi-parameter detection system based on hydrodynamic sequential injection for sensitive determination of phosphate, nitrite, and nitrate in water samples

被引:0
|
作者
Khongpet, Wanpen [1 ]
Yanu, Pattama [1 ]
Pencharee, Somkid [2 ]
Puangpila, Chanida [1 ,5 ]
Hartwell, Supaporn Kradtap [3 ]
Lapanantnoppakhun, Somchai [1 ,5 ]
Yodthongdee, Yutdanai [1 ]
Paukpol, Autchara [1 ]
Jakmunee, Jaroon [1 ,4 ,5 ]
机构
[1] Chiang Mai Univ, Fac Sci, Dept Chem, Lab Analyt Instrumentat & Electrochem Innovat, Chiang Mai 50200, Thailand
[2] Ubon Ratchathani Univ, Fac Sci, Dept Phys, Ubon Ratchathani 34190, Thailand
[3] Xavier Univ, Dept Chem, 3800 Victory Pkwy, Cincinnati, OH 45207 USA
[4] Chiang Mai Univ, Fac Sci, Environm Sci Res Ctr, Ctr Excellence Innovat Chem, Chiang Mai 50200, Thailand
[5] Chiang Mai Univ, Res Ctr Chem Dev Hlth Promoting Prod Northern Res, Fac Sci, Chiang Mai 50200, Thailand
关键词
ENVIRONMENTAL-SAMPLES; LIQUID-CHROMATOGRAPHY; REACTIVE PHOSPHATE; DEVICE; ORTHOPHOSPHATE; ANALYZER; SENSOR;
D O I
10.1039/c9ay02327e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A miniaturized microfluidic hydrodynamic sequential injection system for multi-parameter analysis with a sensitive colorimetric detection was developed to improve the analytical performance for the measurement of phosphate, nitrite, and nitrate based on molybdenum blue and Griess methods. A homemade colorimetric detection with a light emitting diode as a light source and phototransistor light sensor was integrated into the microfluidic platform to achieve a low cost compact system with low reagent consumption and high sensitivity. Under the optimized working conditions, a linear calibration graph of phosphate (two working range), nitrite and nitrate (as nitrogen, N) in the range of 0.01-0.1 and 0.3-1.0 mg of PO43- P L-1, 0.005-0.05 mg of NO2- N L-1 and 0.01-0.12 mg of NO3- N L-1, respectively were achieved with a sample-throughput of 10 h(-1). The limit of detections were 0.005 mg of PO43- P L-1, 0.0026 mg of NO2- N L-1 and 0.005 mg of NO3- N L-1. The percentage of recovery for phosphate, nitrite, and nitrate were 90.3-115.0, 90.0-117.0 and 91.3-117.0, respectively, with relative standard deviations in the range of 1.07-4.90%. Capabilities of the developed device for consecutive analysis of multiple analytes were demonstrated to be an excellent choice for water quality monitoring.
引用
收藏
页码:855 / 864
页数:10
相关论文
共 50 条
  • [31] Research on Multi-Parameter Portable Water Quality Detection System Based on ZYNQ Image Processing Technology
    Sun, Bingyang
    Yang, Shunsheng
    Yu, Chen
    POLISH JOURNAL OF ENVIRONMENTAL STUDIES, 2023, 32 (02): : 1353 - 1370
  • [32] DIRECT DETERMINATION OF NITRATE AND NITRITE IN SOILS BY USE OF A HYDRODYNAMIC INJECTION PROBE BASED ON FILTRATION-DIALYSIS PROCESSES
    ZHI, Z
    RIOS, A
    VALCARCEL, M
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1994, 57 (04) : 279 - 287
  • [33] Report on interlaboratory testing for the determination of nitrite and nitrate in river-water samples by flow-injection analysis
    Higuchi, K
    Goto, R
    Kawashima, T
    Oguma, K
    Kawase, A
    Ogura, H
    BUNSEKI KAGAKU, 2000, 49 (01) : 35 - 42
  • [34] Development of a sequential injection system for the determination of nitrite and nitrate in waters with different salinity: Application to estuaries in NW Portugal
    Ribeiro Mesquita, Raquel Beatriz
    Oliveira Barbosa Ferreira, Maria Teresa Soares
    Alves Segundo, Ricardo Luiz
    Carvalho Pinheiro Teixeira, Catarina Fernanda
    Bordalo, Adriano Agostinho
    Santos Silva Rangel, Antonio Osmaro
    ANALYTICAL METHODS, 2009, 1 (03) : 195 - 202
  • [35] Spectrophotometric determination of nitrate and nitrite in natural water samples based on an oxime formation reaction of phenol
    Gou, Y
    BUNSEKI KAGAKU, 2000, 49 (04) : 261 - 264
  • [36] Multi-parameter Detection System of Workpiece Transport Based on Image Processing Technology
    Ling, Zhao
    Tao, Wang
    Qin, Mao
    Tong, Zhao
    2011 INTERNATIONAL CONFERENCE ON FUTURE COMPUTER SCIENCE AND APPLICATION (FCSA 2011), VOL 3, 2011, : 61 - 64
  • [37] An Environmentally Friendly Compact Microfluidic Hydrodynamic Sequential Injection System Using Curcuma putii Maknoi & Jenjitt. Extract as a Natural Reagent for Colorimetric Determination of Total Iron in Water Samples
    Namjan, Maneerat
    Kaewwonglom, Natcha
    Dechakiatkrai Theerakarunwong, Chonlada
    Jakmunee, Jaroon
    Khongpet, Wanpen
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2023, 2023
  • [38] Research on denoising of joint detection signal of water quality with multi-parameter based on IEEMD
    Li, Wen
    Li, Dejian
    Ma, Yongyue
    Tian, Wang
    Wen, Xin
    Li, Jie
    OPTOELECTRONICS LETTERS, 2024, 20 (02) : 107 - 115
  • [39] Flow-Injection Analysis Method for the Determination of Nitrite and Nitrate in Natural Water Samples Using a Chemiluminescence NOx Monitor
    Yukio Kanda
    Masafumi Taira
    Analytical Sciences, 2003, 19 : 695 - 699
  • [40] Research on denoising of joint detection signal of water quality with multi-parameter based on IEEMD
    LI Wen
    LI Dejian
    MA Yongyue
    TIAN Wang
    WEN Xin
    LI Jie
    Optoelectronics Letters, 2024, 20 (02) : 107 - 115