Indicator to estimate temperature sensitivity of resonance in temperature measurement by neutron resonance spectroscopy

被引:4
|
作者
Gu, Mu [1 ]
Fang, Hong [1 ]
Liu, Bo [1 ]
Liu, Xiaolin [1 ]
Huang, Shiming [1 ]
Ni, Chen [1 ]
Li, Zeren [2 ]
Wang, Rongbo [2 ]
机构
[1] Tongji Univ, Shanghai Key Lab Special Artificial Microstruct M, Dept Phys, Shanghai 200092, Peoples R China
[2] China Acad Engn Phys, Inst Fluid Phys, Mianyang 621900, Sichuan, Peoples R China
关键词
Neutron resonance; Temperature measurement; Indicator of temperature sensitivity; SHOCK COMPRESSION; RADIOGRAPHY; MOLYBDENUM; INTERFACES; ABSORPTION; PRESSURES; TUNGSTEN; CRYSTAL; BINDING; MODEL;
D O I
10.1016/j.nimb.2011.01.003
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Through series of simplification and simulation, we find that it is the ratio of z (=Delta/Gamma) and sigma(o) (cross-section at the exact resonance energy in the absence of temperature broadening) that contains the most information of temperature sensitivity for a resonance. We consequently define a factor h called the effective fitness indicator to represent the lower limit of temperature error for each resonance. Is bears succinct forms and is tested against numerical simulations as well as gathered experimental data. Our further analysis and simulation justify the use of h at high temperatures (above several hundreds degrees centigrade). When the transmission of a resonance is free from suffering a flat-bottom (without nt sigma(o) >> 1), h can be used to estimate the temperature sensitivity of individual resonance with an analytic formula constructed from fitting, telling a relation between the temperature error and h. Moreover, spread of emission time caused by the moderator, phosphorescent decay of the scintillator, and background fraction are all included in numerical simulations to reveal their influences. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:528 / 538
页数:11
相关论文
共 50 条
  • [31] NEUTRON RESONANCE SPECTROSCOPY - CALCIUM
    SINGH, UN
    LIOU, HI
    RAINWATER, J
    HACKEN, G
    MAKOFSKE, W
    GARG, JB
    PHYSICAL REVIEW C, 1974, 10 (06): : 2143 - 2146
  • [32] NON-INTRUSIVE TEMPERATURE-MEASUREMENT OF THE COMPONENTS OF A WORKING CATALYST BY NEUTRON RESONANCE RADIOGRAPHY
    FROST, JC
    MEEHAN, P
    MORRIS, SR
    WARD, RC
    MAYERS, J
    CATALYSIS LETTERS, 1989, 2 (02) : 97 - 104
  • [35] Cladding Mode Resonance Based Fiber for Temperature Measurement
    Xiang, Wenchao
    Pang, Fufei
    Guo, Hairun
    Chen, Na
    Chen, Zhenyi
    Wang, Tingyun
    2008 CHINA-JAPAN JOINT MICROWAVE CONFERENCE (CJMW 2008), VOLS 1 AND 2, 2008, : 524 - 526
  • [36] TEMPERATURE MEASUREMENT IN NUCLEAR MAGNETIC RESONANCE WITH A SPINNING THERMISTOR
    VANGEET, AL
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1969, 40 (01): : 177 - &
  • [37] Thermodynamic temperature measurement by microwave resonance at two cylinders
    Division of Thermophysics and Process Measurements, National Institute of Metrology, Beijing 100013, China
    不详
    Zhang, J.-T. (zhangjint@nim.ac.cn), 1600, Science Press (34):
  • [38] Noninvasive temperature measurement in vivo using a temperature-sensitive lanthanide complex and H-1 magnetic resonance spectroscopy
    Frenzel, T
    Roth, K
    Kossler, S
    Raduchel, B
    Bauer, H
    Platzek, J
    Weinmann, HJ
    MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (03) : 364 - 369
  • [39] Noninvasive temperature measurement in vivo using a temperature-sensitive lanthanide complex and 1H magnetic resonance spectroscopy
    Research Laboratories, Schenng AG, Berlin, Germany
    不详
    不详
    MAGN. RESON. MED., 3 (364-369):
  • [40] High sensitivity stark spectroscopy obtained by surface plasmon resonance measurement
    Wang, S
    Boussaad, S
    Wang, S
    Tao, NJ
    ANALYTICAL CHEMISTRY, 2000, 72 (17) : 4003 - 4008