3D prompt gamma imaging for proton beam range verification

被引:105
|
作者
Draeger, E. [1 ]
Mackin, D. [2 ]
Peterson, S. [3 ]
Chen, H. [1 ]
Avery, S. [4 ]
Beddar, S. [2 ,5 ]
Polf, J. C. [1 ]
机构
[1] Univ Maryland, Sch Med, Dept Radiat Oncol, 22 South Greene St, Baltimore, MD 21201 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, 1515 Holcombe Blvd, Houston, TX 77030 USA
[3] Univ Cape Town, Dept Phys, ZA-7700 Cape Town, South Africa
[4] Univ Penn, Dept Radiat Oncol, 3400 Civ Ctr Blvd, Philadelphia, PA 19104 USA
[5] Univ Texas Houston, Grad Sch Biomed Sci Houston, 6767 Bertner Ave, Houston, TX 77030 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2018年 / 63卷 / 03期
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
Compton imaging; prompt gamma; proton therapy; range verification; COMPTON CAMERA; RAY EMISSION; THERAPY; RECONSTRUCTION; RADIOTHERAPY; ENERGY; IRRADIATION; SIMULATION; DETECTORS; RADIATION;
D O I
10.1088/1361-6560/aaa203
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We tested the ability of a single Compton camera (CC) to produce 3-dimensional (3D) images of prompt gammas (PGs) emitted during the irradiation of a tissue-equivalent plastic phantom with proton pencil beams for clinical doses delivered at clinical dose rates. PG measurements were made with a small prototype CC placed at three different locations along the proton beam path. We evaluated the ability of the CC to produce images at each location for two clinical scenarios: (1) the delivery of a single 2 Gy pencil beam from a hypo-fractionated treatment (similar to 9 x 10(8) protons), and (2) a single pencil beam from a standard treatment (similar to 1 x 10(8) protons). Additionally, the data measured at each location were combined to simulate measurements with a larger scale, clinical CC and its ability to image shifts in the Bragg peak (BP) range for both clinical scenarios. With our prototype CC, the location of the distal end of the BP could be seen with the CC placed up to 4 cm proximal or distal to the BP distal falloff. Using the data from the simulated full scale clinical CC, 3D images of the PG emission were produced with the delivery of as few as 1 x 10(8) protons, and shifts in the proton beam range as small as 2 mm could be detected for delivery of a 2 Gy spot. From these results we conclude that 3D PG imaging for proton range verification under clinical beam delivery conditions is possible with a single CC.
引用
收藏
页数:13
相关论文
共 50 条
  • [11] Progress towards a semiconductor Compton camera for prompt gamma imaging during proton beam therapy for range and dose verification
    Gutierrez, A.
    Baker, C.
    Boston, H.
    Chung, S.
    Judson, D. S.
    Kacperek, A.
    Le Crom, B.
    Moss, R.
    Royle, G.
    Speller, R.
    Boston, A. J.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [12] Optimisation of a Prompt-Gamma Slit Imaging System for Particle Beam Range Verification
    Vella, A.
    Van den Heuvel, F.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S122 - S122
  • [13] Prompt Gamma Timing Range Verification for Scattered Proton Beams
    Kormoll, T.
    Duplicy, A.
    Fiedler, F.
    Golnik, C.
    Gonzalez, F. Hueso
    Petzoldt, J.
    Swanson, R.
    Thiele, J.
    Weinberger, D.
    Werner, T.
    Enghardt, W.
    Pausch, G.
    2015 4TH INTERNATIONAL CONFERENCE ON ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA), 2015,
  • [14] Application of the HICAM Camera for Imaging of Prompt Gamma Rays in Measurements of Proton Beam Range
    Peloso, R.
    Busca, P.
    Fiorini, C.
    Basilavecchia, M.
    Frizzi, T.
    Smeets, J.
    Roellinghoff, F.
    Prieels, D.
    Stichelbaut, F.
    Benilov, A.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2285 - 2289
  • [15] Hybrid in-beam PET- and Compton prompt-gamma imaging aimed at enhanced proton-range verification
    J. Balibrea-Correa
    J. Lerendegui-Marco
    I. Ladarescu
    C. Guerrero
    T. Rodríguez-González
    M. C. Jiménez-Ramos
    B. Fernández-Martínez
    C. Domingo-Pardo
    The European Physical Journal Plus, 137
  • [16] Hybrid in-beam PET- and Compton prompt-gamma imaging aimed at enhanced proton-range verification
    Balibrea-Correa, J.
    Lerendegui-Marco, J.
    Ladarescu, I
    Guerrero, C.
    Rodriguez-Gonzalez, T.
    Jimenez-Ramos, M. C.
    Fernandez-Martinez, B.
    Domingo-Pardo, C.
    EUROPEAN PHYSICAL JOURNAL PLUS, 2022, 137 (11):
  • [17] A Method to Improve the Spatial Resolution of Prompt Gamma Based Compton Imaging for Proton Range Verification
    Draeger, E.
    Mackin, D.
    Peterson, S.
    Chen, H.
    Beddar, S.
    Polf, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3451 - 3451
  • [18] Deep Learning-Based Prompt-Gamma Imaging for Range Verification in Proton Radiotherapy
    Jiang, Z.
    Polf, J.
    Ren, L.
    MEDICAL PHYSICS, 2022, 49 (06) : E210 - E210
  • [19] Range verification in proton therapy: Can prompt-gamma imaging identify the source of deviation?
    Khamfongkhruea, C.
    Janssens, G.
    Petzoldt, J.
    Smeets, J.
    Pausch, G.
    Richter, C.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S296 - S297
  • [20] Gamma electron vertex imaging and application to beam range verification in proton therapy
    Kim, Chan Hyeong
    Park, Jin Hyung
    Seo, Hee
    Lee, Han Rim
    MEDICAL PHYSICS, 2012, 39 (02) : 1001 - 1005