External quality assessment of serum indices: Spanish SEQC-ML program

被引:2
|
作者
Gomez Rioja, Ruben [1 ]
Ventura, Monserrat [2 ]
Antonia Llopis, Maria [3 ]
Miquel Bauca, Josep [4 ]
Caballero Garralda, Andrea [5 ]
Ibarz, Mercedes [6 ]
Martinez, Debora [7 ]
Gomez, Carolina [3 ]
Salas Gomez-Pablos, Paloma [8 ]
Garcia del Pino, Isabel [9 ]
Delgado, Jose [10 ]
Jose Puente, Juan [11 ]
Marzana, Iciar [12 ]
机构
[1] La Paz Cantoblanco Carlos III Univ Hosp, Lab Med, Madrid, Spain
[2] Spanish Soc Lab Med, Barcelona, Spain
[3] Hosp Badalona Germans Trias & Pujol, Lab Med, Badalona, Barcelona, Spain
[4] Hosp Univ Son Espases, Serv Anal Clin, Palma De Mallorca, Illes Balears, Spain
[5] Lab Echervarne SA, CORE Lab, Castelldefels, Catalunya, Spain
[6] Hosp Arnau Vilanova, Lab Med, Lleida, Catalunya, Spain
[7] Clin Univ Navarra, Navarra, Spain
[8] CORE Lab, Catlab, Barcelona, Spain
[9] Complexo Hosp Univ A Coruna, Area Lab, La Coruna, Spain
[10] Hosp Univ Son Espases, Dept Lab Med, Palma De Mallorca, Mallorca, Spain
[11] Hosp Clin Univ Lozano Blesa, Serv Bioquim, Zaragoza, Spain
[12] Labs Hosp Univ Cruces, Unidad Extraanalit, Baracaldo, Vizcaya, Spain
关键词
external quality assessment (EQA); hemolysis; icterus; lipemia; proficiency testing scheme; serum indices; PREANALYTICAL QUALITY;
D O I
10.1515/cclm-2021-0786
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: Serum indices included in clinical chemistry instruments are widely used by laboratories to assess the quality of samples. Instruments that report quantitative results allow an evaluation of their diagnostic performance in a similar way to other biochemical tests. The Spanish Society of Laboratory Medicine (SEQC-ML) launched a monthly External Quality program of serum indices in 2018 using three lyophilized materials of simultaneous annual distribution. We present the results of the first three years of the program. Methods: The use of four different quality control mate-rials with different concentrations in three alternate months allows an annual evaluation of the participant's accuracy. Assigned values are established by consensus among homogeneous groups, considering necessary at least 10 participants for a comparison at instrument level. The average percentage difference results per instrument allow the assessment of bias among groups. Results: The imprecision of the three indices ranges between 3 and 9%, with no major differences among instruments. Significant differences were observed in all indices among instruments with more than 10 participants (Roche Cobas, Abbott Architect, Abbott Alinity and Siemens Advia). The 90th percentile of the distribution of percentage differences was used as the analytical perfor-mance specification (APS). An improvement in perfor-mance was observed in the first three years of the program, probably due to the learning curve effect. In 2020, APS of 7.8, 12.2 and 9.7% were proposed for hemolytic, icteric and lipemic indices, respectively. Conclusions: Serum indices have a great impact on the quality and the reliability of laboratory test results. Participation in proficiency testing programs for serum indices is helpful to encourage harmonization among providers and laboratories.
引用
收藏
页码:66 / 73
页数:8
相关论文
共 50 条
  • [21] Harmonisation of serum dihydrotestosterone analysis: establishment of an external quality assurance program
    Greaves, Ronda F.
    Jolly, Lisa
    Hartmann, Michaela F.
    Ho, Chung Shun
    Kam, Richard K. T.
    Joseph, John
    Boyder, Conchita
    Wudy, Stefan A.
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2017, 55 (04) : 522 - 529
  • [22] Harmonisation of Serum Dihydrotestosterone Analysis: Establishment of an External Quality Assurance Program
    Wudy, Stefan
    Hartmann, Michaela
    Jolly, Lisa
    Ho, Chung Shun
    Kam, Richard
    Joseph, John
    Boyder, Conchita
    Greaves, Ronda
    [J]. HORMONE RESEARCH IN PAEDIATRICS, 2016, 86 : 92 - 92
  • [23] EXTERNAL QUALITY ASSESSMENT OF SERUM DRUG DETERMINATIONS IN THE NORDIC COUNTRIES
    LESKINEN, E
    NYBERG, A
    ELFVING, S
    HIRVISALO, EL
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1984, 44 : 135 - 145
  • [24] External Quality Assessment for the Determination of Diphtheria Antitoxin in Human Serum
    Di Giovine, Paolo
    Pinto, Antonella
    Olander, Rose-Marie
    Sesardic, Dorothea
    Stickings, Paul
    Berbers, Guy
    Neal, Shona
    Efstratiou, Androulla
    Paberza, Ruta
    Dauksiene, Snieguole
    Bujko, Marina
    Detcheva, Antoaneta
    Joks, Unna
    Levent, Belkis
    von Hunolstein, Christina
    [J]. CLINICAL AND VACCINE IMMUNOLOGY, 2010, 17 (08) : 1282 - 1290
  • [25] EXTERNAL QUALITY ASSESSMENT OF SERUM ALPHA-FETOPROTEIN ASSAYS
    WOODHEAD, JS
    KEMP, HA
    NIX, ABJ
    ROWLANDS, RJ
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 1980, 17 (NOV) : 332 - 333
  • [26] EXTERNAL QUALITY ASSESSMENT OF SERUM HORMONE DETERMINATIONS IN THE NORDIC COUNTRIES
    RUOKONEN, A
    LESKINEN, E
    NYBERG, A
    VIHKO, R
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1984, 44 : 125 - 134
  • [27] External quality assessment for serum proteins: State of the art.
    Plebani, M
    Secchiero, S
    Zardo, L
    Sciacovelli, L
    [J]. CLINICAL CHEMISTRY, 2001, 47 (06) : A35 - A35
  • [28] DETERMINATION OF ALUMINUM IN SERUM - FINDINGS OF AN EXTERNAL QUALITY ASSESSMENT SCHEME
    TAYLOR, A
    STARKEY, BJ
    WALKER, AW
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 1985, 22 (JUL) : 351 - 358
  • [29] EXTERNAL ASSESSMENT PROGRAM OF THE QUALITY IN HEMATOLOGY OF THE SPANISH SOCIETY OF HAEMATOLOGY AND HEMOTHERAPY. ANNUAL REPORT ON THE RESULTS OF THE HEMATOLOGY MODULES IN 2019
    Alcaraz-Quiles, J.
    Molina, A.
    Segurana, A.
    Perez, A.
    Merino, A.
    Jou, J. M.
    Tassies, D.
    Rozman, M.
    Beneitez, D.
    Reverter, J. C.
    Bedini, J. L.
    [J]. HAEMATOLOGICA, 2020, 105 : 325 - 325
  • [30] EXTERNAL ASSESSMENT PROGRAM OF THE QUALITY IN HEMATOLOGY OF THE SPANISH SOCIETY OF HEMATOLOGY AND HEMOTHERAPY. ANNUAL REPORT ON THE RESULTS OF THE HEMATOLOGY MODULES IN 2020
    Alcaraz-Quiles, J.
    Molina-Borras, A.
    Perez, A.
    Segurana, A.
    Merino, A.
    Tassies, D.
    Rozman, M.
    Beneitez, D.
    Reverter, J. C.
    Bedini, J. L.
    [J]. HAEMATOLOGICA, 2021, 106 (10) : 320 - 320