External quality assessment of serum indices: Spanish SEQC-ML program

被引:2
|
作者
Gomez Rioja, Ruben [1 ]
Ventura, Monserrat [2 ]
Antonia Llopis, Maria [3 ]
Miquel Bauca, Josep [4 ]
Caballero Garralda, Andrea [5 ]
Ibarz, Mercedes [6 ]
Martinez, Debora [7 ]
Gomez, Carolina [3 ]
Salas Gomez-Pablos, Paloma [8 ]
Garcia del Pino, Isabel [9 ]
Delgado, Jose [10 ]
Jose Puente, Juan [11 ]
Marzana, Iciar [12 ]
机构
[1] La Paz Cantoblanco Carlos III Univ Hosp, Lab Med, Madrid, Spain
[2] Spanish Soc Lab Med, Barcelona, Spain
[3] Hosp Badalona Germans Trias & Pujol, Lab Med, Badalona, Barcelona, Spain
[4] Hosp Univ Son Espases, Serv Anal Clin, Palma De Mallorca, Illes Balears, Spain
[5] Lab Echervarne SA, CORE Lab, Castelldefels, Catalunya, Spain
[6] Hosp Arnau Vilanova, Lab Med, Lleida, Catalunya, Spain
[7] Clin Univ Navarra, Navarra, Spain
[8] CORE Lab, Catlab, Barcelona, Spain
[9] Complexo Hosp Univ A Coruna, Area Lab, La Coruna, Spain
[10] Hosp Univ Son Espases, Dept Lab Med, Palma De Mallorca, Mallorca, Spain
[11] Hosp Clin Univ Lozano Blesa, Serv Bioquim, Zaragoza, Spain
[12] Labs Hosp Univ Cruces, Unidad Extraanalit, Baracaldo, Vizcaya, Spain
关键词
external quality assessment (EQA); hemolysis; icterus; lipemia; proficiency testing scheme; serum indices; PREANALYTICAL QUALITY;
D O I
10.1515/cclm-2021-0786
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: Serum indices included in clinical chemistry instruments are widely used by laboratories to assess the quality of samples. Instruments that report quantitative results allow an evaluation of their diagnostic performance in a similar way to other biochemical tests. The Spanish Society of Laboratory Medicine (SEQC-ML) launched a monthly External Quality program of serum indices in 2018 using three lyophilized materials of simultaneous annual distribution. We present the results of the first three years of the program. Methods: The use of four different quality control mate-rials with different concentrations in three alternate months allows an annual evaluation of the participant's accuracy. Assigned values are established by consensus among homogeneous groups, considering necessary at least 10 participants for a comparison at instrument level. The average percentage difference results per instrument allow the assessment of bias among groups. Results: The imprecision of the three indices ranges between 3 and 9%, with no major differences among instruments. Significant differences were observed in all indices among instruments with more than 10 participants (Roche Cobas, Abbott Architect, Abbott Alinity and Siemens Advia). The 90th percentile of the distribution of percentage differences was used as the analytical perfor-mance specification (APS). An improvement in perfor-mance was observed in the first three years of the program, probably due to the learning curve effect. In 2020, APS of 7.8, 12.2 and 9.7% were proposed for hemolytic, icteric and lipemic indices, respectively. Conclusions: Serum indices have a great impact on the quality and the reliability of laboratory test results. Participation in proficiency testing programs for serum indices is helpful to encourage harmonization among providers and laboratories.
引用
收藏
页码:66 / 73
页数:8
相关论文
共 50 条
  • [11] External quality assessment program on urinary dysmorphic erythrocytes
    Tesser Poloni, Jose Antonio
    da Silva Carpeggiani, Fernanda Pereira
    Tavares da Silva, Isabel Antas
    de Oliveira, Janaina A.
    Tobler, Juliana Barroso
    Saldanha, Edmo M.
    Rotta, Liane N.
    [J]. CLINICA CHIMICA ACTA, 2017, 475 : 20 - 21
  • [12] External quality assessment program for dispensary only facilities
    Padget, BJ
    Hannon, JL
    [J]. TRANSFUSION, 2004, 44 (09) : 168A - 169A
  • [13] An external quality assessment program for the PFA-100
    Favaloro, E. J.
    Bonar, R.
    Marsden, K.
    [J]. JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2009, 7 : 568 - 568
  • [14] EXTERNAL QUALITY ASSESSMENT PROGRAM FOR COPPER AND ZINC IN SERUM - ANALYTICAL PERFORMANCE FOR THE 1ST YEAR
    BARUTHIO, F
    PIERRE, F
    ARNAUD, J
    [J]. ANNALES DE BIOLOGIE CLINIQUE, 1990, 48 (04) : 239 - 246
  • [15] EXTERNAL QUALITY ASSESSMENT OF TECHNIQUES FOR ASSAY OF SERUM ETHANOL
    WILSON, JF
    BARNETT, K
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 1995, 32 : 540 - 544
  • [16] Twelve years of the Brazilian External Quality Assessment Program in Immunohematology: Benefits of the program
    Melo, L
    Pellegrino, J
    Bianco, C
    Castilho, L
    [J]. JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2005, 19 (05) : 209 - 218
  • [17] An Italian External Quality Assessment (EQA) program on urinary sediment
    Fogazzi, Giovanni B.
    Secchiero, Sandra
    Consonni, Dario
    Sciacovelli, Laura
    Zardo, Lorena
    Garigali, Giuseppe
    Verdesca, Simona
    Messa, Piergiorgio
    Plebani, Mario
    [J]. CLINICA CHIMICA ACTA, 2010, 411 (11-12) : 859 - 867
  • [18] EXTERNAL QUALITY ASSESSMENT IN MEXICO - A 5-YEAR PROGRAM
    CASTILLODESANCHEZ, ML
    [J]. CLINICAL CHEMISTRY, 1990, 36 (06) : 940 - 941
  • [19] THE NORWEGIAN EXTERNAL QUALITY ASSESSMENT PROGRAM FOR BACTERIOLOGY, MYCOLOGY AND PARASITOLOGY
    SANDVEN, P
    LASSEN, J
    [J]. MEDICAL MICROBIOLOGY LETTERS, 1994, 3 (03): : 138 - 141
  • [20] USE OF FRESH SERUM POOLS FOR THE EXTERNAL ENDOCRINOLOGY QUALITY ASSURANCE PROGRAM
    WONG, PY
    ENGLAND, T
    LUXTON, AW
    MEE, AV
    MURRAY, S
    WALKER, WC
    WEBB, S
    WOOD, DE
    [J]. CLINICAL CHEMISTRY, 1990, 36 (06) : 1002 - 1002