Patient Data-Based Monte Carlo Simulation of In-beam Single-Ring OpenPET Imaging

被引:0
|
作者
Tashima, Hideaki [1 ]
Kurz, Christopher [2 ,3 ]
Yoshida, Eiji [1 ]
Debus, Juergen [3 ]
Parodi, Katia [2 ,3 ]
Yamaya, Taiga [1 ]
机构
[1] Natl Inst Radiol Sci, Chiba 2638555, Japan
[2] Ludwig Maximilians Univ Munchen, Munich, Germany
[3] Heidelberg Univ Hosp, Heidelberg, Germany
关键词
PET; VERIFICATION; PROTON; SYSTEM;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We are developing the OpenPET, which can provide an open space to make the patient accessible during positron emission tomography (PET) measurements. The OpenPET provides PET measurements during particle therapy such as carbon ion beam treatment, enabling visualization of the irradiation field of the patient as well as direct tumor tracking with a real-time imaging system. In the carbon ion beam treatment, positron emitters are produced by the fragmentation reactions. Therefore, by means of PET, it can be confirmed whether or not the dose distribution in the treatment plan and that in the actual irradiation are matched. In this study, we conducted Monte Carlo simulations based on clinical patient data for scanned C-12 ion beam irradiation to investigate the effectiveness of the OpenPET geometry compared with offline PET measurements. Production rates of the positron emitters were calculated based on the patient CT image and physical dose information in the treatment plan by the FLUKA code. The activity distribution averaged over the measurement time was calculated from the production rates by an analytical model including activity decay and biological washout effects. Annihilation gamma ray events from the activity distribution were simulated by the Geant4 Monte Carlo toolkit. Activity distribution images were reconstructed by the list-mode maximum a posteriori ordered subset expectation maximization. As a result, we found the online OpenPET with a measurement time of 10 minutes could detect a similar number of list-mode data events as an offline PET with a measurement time of 30 minutes. Reconstructed images for the online OpenPET contained activity distribution not only around the distal edge but also at the entrance area of the irradiation field. The offline PET showed strong noise before the Bragg peak position. The simulation results showed that online OpenPET could achieve good quality of images with a short measurement time.
引用
收藏
页数:3
相关论文
共 50 条
  • [41] Monte Carlo simulation of an x-ray volume imaging cone beam CT unit
    Spezi, Emiliano
    Downes, Patrick
    Radu, Emil
    Jarvis, Richard
    [J]. MEDICAL PHYSICS, 2009, 36 (01) : 127 - 136
  • [42] Ultra-Fast Monte Carlo Simulation for Cone Beam CT Imaging of Brain Trauma
    Sisniega, A.
    Zbijewski, W.
    Stayman, J.
    Yorkston, J.
    Aygun, N.
    Koliatsos, V.
    Siewerdsen, J.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 542 - 542
  • [43] Thorax organ dose estimation in computed tomography based on patient CT data using Monte Carlo simulation
    Mohammadi, Gh. R. Fallah
    Alam, N. Riyahi
    Geraily, Gh.
    Paydar, R.
    [J]. INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2016, 14 (04): : 313 - 321
  • [44] Monte-Carlo based validation of accelerator beam base data measurements
    Alber, M.
    Soehn, M.
    Sikora, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S378 - S379
  • [45] Spaceborne imaging simulation of ship based on Monte Carlo ray tracing method
    Wang Biao
    He Hong-fei
    Lin Jia-xuan
    [J]. REMOTE SENSING AND MODELING OF THE ATMOSPHERE, OCEANS, AND INTERACTIONS V, 2014, 9265
  • [46] Single pencil beam benchmark of a module for Monte Carlo simulation of proton transport in the PENELOPE code
    Verbeek, Nico
    Wulff, Joerg
    Baeumer, Christian
    Smyczek, Sabrina
    Timmermann, Beate
    Brualla, Lorenzo
    [J]. MEDICAL PHYSICS, 2021, 48 (01) : 456 - 476
  • [47] Simulation analysis of electron imaging method based on Monte Carlo simulation and particle tracer software
    Wang, Zhiyuan
    Du, Yingchao
    Huang, Wenhui
    [J]. Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2014, 26 (11):
  • [48] In-beam tests of a PET demonstrator (LAPD) for hadrontherapy beam ballistic control: data comparison to Geant4 Monte-Carlo predictions.
    Binet, Sebastien
    Bongrand, Arthur
    Busato, Emmanuel
    Insa, Christophe
    Lambert, Daniel
    Magne, Magali
    Martin, Franck
    Montarou, Gerard
    Rozes, Arnaud
    [J]. ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA 2019), 2020, 225
  • [49] An improved Gaussian laser beam probability distribution simulation based on Monte Carlo method
    Gao, Di
    Li, Yanhui
    [J]. MODERN PHYSICS LETTERS B, 2020, 34 (36):
  • [50] Fast Monte Carlo simulation for patient-specific CT/CBCT imaging dose calculation
    Jia, Xun
    Yan, Hao
    Gu, Xuejun
    Jiang, Steve B.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (03): : 577 - 590