Single pencil beam benchmark of a module for Monte Carlo simulation of proton transport in the PENELOPE code

被引:15
|
作者
Verbeek, Nico [1 ,2 ,3 ]
Wulff, Joerg [1 ,3 ]
Baeumer, Christian [1 ,3 ,4 ,5 ]
Smyczek, Sabrina [1 ,3 ,6 ]
Timmermann, Beate [1 ,2 ,3 ,4 ,7 ]
Brualla, Lorenzo [1 ,2 ,3 ]
机构
[1] West German Proton Therapy Ctr Essen WPE, Essen, Germany
[2] Univ Duisburg Essen, Fac Med, Essen, Germany
[3] Univ Hosp Essen, West German Canc Ctr WTZ, Essen, Germany
[4] German Canc Consortium DKTK, Radiat Oncol & Imaging, Heidelberg, Germany
[5] Tech Univ Dortmund, Otto Hahn Str 4a, D-44227 Dortmund, Germany
[6] Heinrich Heine Univ Dusseldorf HHU, Fac Phys, Dusseldorf, Germany
[7] Univ Hosp Essen, Dept Particle Therapy, Essen, Germany
关键词
beam modeling; Geant4; Monte Carlo; PENELOPE; PENH; proton; TOPAS; SCANNED PROTON; ALGORITHM; PHOTON; DOSIMETRY;
D O I
10.1002/mp.14598
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background and purpose PENH is a recently coded module for simulation of proton transport in conjunction with the Monte Carlo code PENELOPE. PENELOPE applies class II simulation to all type of interactions, in particular, to elastic collisions. PENH uses calculated differential cross sections for proton elastic collisions that include electron screening effects as well as nuclear structure effects. Proton-induced nuclear reactions are simulated from information in the ENDF-6 database or from alternative nuclear databases in ENDF format. The purpose of this work is to benchmark this module by simulating absorbed dose distributions from a single finite spot size proton pencil beam in water. Materials and methods Monte Carlo simulations with PENH are compared with simulation results from TOPAS Monte Carlo (v3.1p2) and RayStation Monte Carlo (v6). Different beam models are examined in terms of mean energy and energy spread to match the measured profiles. The phase-space file is derived from experimental measurements. Simulated absorbed dose distributions are compared to experimental data obtained with the ionization chamber array MatriXX 2D detector (IBA Dosimetry) in a water tank. The experiments were conducted with a clinical IBA pencil beam scanning dedicated nozzle. In all simulations a Fermi-Eyges phase-space representation of a single finite spot size proton pencil beam is used. Results In general, there is a good agreement between simulated results and experimental data up to a distance of 3 cm from the central axis. In the core region (region where the dose is more than 10% of the maximum dose) PENH shows, overall, the smallest deviations from experimental data, with the largest radial rms (root mean square) smaller than 0.2. The results achieved by TOPAS and RayStation in that region are very close to those of PENH. For the halo region, that is the area of the dose distribution outside the core region reaching down to 0.01% of the maximum intensity, the largest rms achieved by TOPAS is always smaller than 0.5, yielding better results than the rest of the codes. Conclusion The physics modeling of the PENELOPE/PENH code yields results consistent with measurements in the dose range relevant for proton therapy. The discrepancies between PENH appearing at distances larger than 3 cm from the central-beam axis are accountable to the lack of neutron simulation in this code. In contradistinction, TOPAS has a better agreement with experimental data at large distances from the central-beam axis because of the simulation of neutrons.
引用
收藏
页码:456 / 476
页数:21
相关论文
共 50 条
  • [1] Benchmarking of a module for Monte Carlo simulation of proton transport in the PENELOPE code
    Verbeek, N.
    Smyczek, S.
    Wulff, J.
    Baeumer, C.
    Timmermann, B.
    Brualla, L.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S479 - S480
  • [2] Benchmarking of a Module for the Monte Carlo Simulation of Proton Transport in the PENELOPE Code
    Verbeek, N.
    Smyczek, S.
    Wulff, J.
    Baeumer, C.
    Timmermann, B.
    Brualla, L.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2019, 195 : S179 - S179
  • [3] A code for the automatic Monte Carlo simulation of linacs using PENELOPE
    Brualla, L.
    Sauerwein, W.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2009, 185 : 50 - 50
  • [4] Validation and clinical implementation of an accurate Monte Carlo code for pencil beam scanning proton therapy
    Huang, Sheng
    Kang, Minglei
    Souris, Kevin
    Ainsley, Christopher
    Solberg, Timothy D.
    McDonough, James E.
    Simone, Charles B.
    Lin, Liyong
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (05): : 558 - 572
  • [5] The Application of Cloud Computing in Pencil Beam Scanning Proton Therapy Monte Carlo Simulation
    Wang, Z.
    Gao, M.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 296 - 296
  • [6] Monte Carlo model of a gantry for proton pencil beam scanning
    Winterhalter, Carla
    Safai, Sairos
    Grassberger, Clemens
    Oxley, David
    Weber, Damien C.
    Lomax, Tony
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (11) : 837 - 837
  • [7] Accurate simulation of ionisation chamber response with the Monte Carlo code PENELOPE
    Sempau, Josep
    Andreo, Pedro
    [J]. XXXIII BRAZILIAN WORKSHOP ON NUCLEAR PHYSICS, 2011, 1351
  • [8] The effect of voxelization in Monte Carlo simulation to validate Bragg peak characteristics for a pencil proton beam
    Price, Gumec M. Gungor
    Sarigul, Neslihan
    [J]. REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2023, 28 (01) : 102 - 113
  • [9] Validation and Implementation of Proton Pencil Beam Scanning Nozzle Using TOPAS Monte Carlo Simulation
    Lin, C.
    Feng, Y.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E875 - E875
  • [10] Experimental benchmarks of the Monte Carlo code PENELOPE
    Sempau, J
    Fernández-Varea, JM
    Acosta, E
    Salvat, F
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2003, 207 (02): : 107 - 123