Computer-aided detection systems for breast masses: Comparison of performances on full-field digital mammograms and digitized screen-film mammograms

被引:21
|
作者
Wei, Jun [1 ]
Hadjiiski, Lubomir M. [1 ]
Sahiner, Berkman [1 ]
Chan, Heang-Ping [1 ]
Ge, Jun [1 ]
Roubidoux, Marilyn A. [1 ]
Helvie, Mark A. [1 ]
Zhou, Chuan [1 ]
Wu, Yi-Ta [1 ]
Paramagul, Chintana [1 ]
Zhang, Yiheng [1 ]
机构
[1] Univ Michigan, Dept Radiol, Ann Arbor, MI 48109 USA
关键词
computer-aided detection; mass detection; full-field digital mammogram (FFDM); screen-film mammogram (SFM); free-response receiver operating characteristic (FROC);
D O I
10.1016/j.acra.2007.02.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. To compare the performance of computer aided detection (CAD) systems on pairs of full-field digital mammogram (FFDM) and screen-film mammogram (SFM) obtained from the same patients. Materials and Methods. Our CAD systems on both modalities have similar architectures that consist of five steps. For FFDMs, the input raw image is first log-transformed and enhanced by a multiresolution preprocessing scheme. For digitized SFMs, the input image is smoothed and subsampled to a pixel size of 100 mu m x 100 mu m. For both CAD systems, the mammogram after preprocessing undergoes a gradient field analysis followed by clustering-based region growing to identify suspicious breast structures. Each of these structures is refined in a local segmentation process. Morphologic and texture features are then extracted from each detected structure, and trained rule-based and linear discriminant analysis classifiers are used to differentiate masses from normal tissues. Two datasets, one with masses and the other without masses, were collected. The mass dataset contained 131 cases with 131 biopsy proven masses, of which 27 were malignant and 104 benign. The true locations of the masses were identified by an experienced Mammography Quality Standards Act (MQSA) radiologist. The no-mass data set contained 98 cases. The time interval between the FFDM and the corresponding SFM was 0 to 118 days. Results. Our CAD system achieved case-based sensitivities of 70%, 80%, and 90% at 0.9, 1.5, and 2.6 false positive (FP) marks/image, respectively, on FFDMs, and the same sensitivities at 1.0, 1.4, and 2.6 Fl? marks/image, respectively, on SFMs. Conclusions. The difference in the performances of our FFDM and SFM CAD systems did not achieve statistical significance.
引用
收藏
页码:659 / 669
页数:11
相关论文
共 50 条
  • [41] Detection of Breast Cancer with Full-Field Digital Mammography and Computer-Aided Detection
    The, Juliette S.
    Schilling, Kathy J.
    Hoffmeister, Jeffrey W.
    Friedmann, Euvondia
    McGinnis, Ryan
    Holcomb, Richard G.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (02) : 337 - 340
  • [42] Screen-film versus full-field digital mammography:: Comparison in breast cancer screening
    Sigfússon, BF
    [J]. ACTA RADIOLOGICA, 2005, 46 (07) : 663 - 663
  • [43] Clinical comparison of full-field digital mammography and screen-film mammography of breast cancer
    Lewin, JM
    D'Orsi, CJ
    Hendrick, RE
    Moss, LJ
    Isaacs, PK
    Karellas, A
    Cutter, GR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (03) : 671 - 677
  • [44] Computer-aided diagnosis: Analysis of mammographic parenchymal patterns and classification of masses on digitized mammograms
    Huo, ZM
    Giger, ML
    Vyborny, CJ
    Olopade, FI
    Wolverton, DE
    [J]. PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 1017 - 1020
  • [45] Computer-aided detection of breast masses on mammograms: performance improvement using a dual system
    Wei, J
    Sahiner, B
    Hadjiiski, LM
    Chan, HP
    Helvie, MA
    Roubidoux, MA
    Petrick, N
    Ge, J
    Zhou, C
    [J]. Medical Imaging 2005: Image Processing, Pt 1-3, 2005, 5747 : 9 - 15
  • [46] Computer-based reading of full-field digital mammograms
    Obenauer, S
    Luftner-Nagel, S
    Hermann, KP
    Grabbe, E
    [J]. DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2003, : 449 - 451
  • [47] Computer-aided detection of breast masses on mammograms: Bilateral analysis for false positive reduction
    Wu, Yi-Ta
    Hadjiiski, Lubomir M.
    Wei, Jun
    Zhou, Chuan
    Sahiner, Berkman
    Chan, Heang-Ping
    [J]. MEDICAL IMAGING 2006: IMAGE PROCESSING, PTS 1-3, 2006, 6144
  • [48] Impact of Breast Density on Computer-Aided Detection in Full-Field Digital Mammography
    Silvia Obenauer
    Christian Sohns
    Carola Werner
    Eckhardt Grabbe
    [J]. Journal of Digital Imaging, 2006, 19
  • [49] Impact of breast density on computer-aided detection in full-field digital mammography
    Obenauer, Silvia
    Sohns, Christian
    Werner, Carola
    Grabbe, Eckhardt
    [J]. JOURNAL OF DIGITAL IMAGING, 2006, 19 (03) : 258 - 263
  • [50] A comparison of full-field digital mammograms versus 2D synthesized mammograms for detection of microcalcifications on screening
    Wahab, Rifat A.
    Lee, Su-Ju
    Zhang, Bin
    Sobel, Lawrence
    Mahoney, Mary C.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2018, 107 : 14 - 19