Breast tumor size assessment: Comparison of conventional ultrasound and contrast-enhanced ultrasound

被引:49
|
作者
Jiang, Yu-Xin [1 ]
Liu, He [1 ]
Liu, Ji-Bin [2 ]
Zhu, Qing-Li [1 ]
Sun, Qiang [3 ]
Chang, Xiao-Yan [4 ]
机构
[1] Chinese Acad Med Sci, Peking Union Med Coll Hosp, Dept Diagnost Ultrasound, Beijing 100730, Peoples R China
[2] Thomas Jefferson Univ, Dept Radiol, Philadelphia, PA 19107 USA
[3] Chinese Acad Med Sci, Peking Union Med Coll Hosp, Dept Surg, Beijing 100730, Peoples R China
[4] Chinese Acad Med Sci, Peking Union Med Coll Hosp, Dept Pathol, Beijing 100730, Peoples R China
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2007年 / 33卷 / 12期
关键词
breast; contrast-enhanced ultrasound; tumor measurement; pathology;
D O I
10.1016/j.ultrasmedbio.2007.06.002
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Accurate assessment of tumor size is necessary when selecting patients for breast-conserving surgery. In the study of breast contrast-enhanced ultrasound (CEUS), we found that tumor size discrepancy between CEUS and conventional ultrasound (US) existed in some breast lesions, for which the reasons are not clear. Breast CEUS examinations were performed in 104 patients with breast lesions. The measurement of the 104 breast tumors on conventional US was obtained and compared with the measurement on CEUS. A difference in measuring tumor size of > 3 mm for tumors up to 1.7 cm and 4 mm for tumors >= 1.7 cm, was defined as a significant discrepancy between conventional US and CEUS. The histopathological examination of size discrepancy was performed and the margin characteristics of breast cancers with larger measurements were compared with those with unchanged measurements. Among the 104 lesions (43 malignant, 60 benign, I borderline), the size of 27 breast cancers and one granulomatous mastitis appeared larger at CEUS. Pathologic examinations of the region corresponding to the measurement discrepancy were mainly ductal carcinomas in situ (DCIS), invasive carcinoma with a DCIS component, adenosis with lobular hyperplasia in breast cancers and inflammatory cell infiltration in one granulomatous mastitis. Well-defined margin characteristics were significantly different between breast cancers with larger measurements at CEUS and those with unchanged measurements of size (p = 0.002), whereas no significant difference was found between the two groups in ill-defined, spiculated, hyperechoic halo, microlobulated and angulated margins (p = 0.463, 0.117, 0.194, 0.666 and 0.780, respectively). This initial study suggests that significant discrepancy of breast lesion measurement between conventional US and CEUS is more likely presented in breast cancer than benign lesions. The pathologic findings corresponding to the region of size increased at CEUS are malignant in most malignant lesions and benign in benign lesions. It is difficult to predict whether the size measurement of the breast cancer increases at CEUS based on the margin characteristics showed on conventional US. (E-mail: yuxinjiangxh@yahoo.com.cn) (c) 2007 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1873 / 1881
页数:9
相关论文
共 50 条
  • [41] Contrast-enhanced ultrasound (CEUS) in spinal tumor surgery
    Prada, Francesco
    Vetrano, Ignazio G.
    DiMeco, Francesco
    ACTA NEUROCHIRURGICA, 2018, 160 (09) : 1869 - 1871
  • [42] Brain tumor classification on intraoperative contrast-enhanced ultrasound
    Ritschel, Kai
    Pechlivanis, Ioannis
    Winter, Susanne
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2015, 10 (05) : 531 - 540
  • [43] Bladder Tumor Staging: Comparison of Contrast-Enhanced and Gray-Scale Ultrasound
    Caruso, Giuseppe
    Salvaggio, Giuseppe
    Campisi, Antonella
    Melloni, Darwin
    Midiri, Massimo
    Bertolotto, Michele
    Lagalla, Roberto
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (01) : 151 - 156
  • [44] Contrast-enhanced ultrasound for guidance of local tumor ablation
    Brown, JM
    Chaloupka, J
    Taylor, KJW
    Quedens-Case, C
    Alderman, J
    Greener, Y
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (08): : 1213 - 1219
  • [45] Intraoperative Contrast-Enhanced Ultrasound for Brain Tumor Surgery
    Prada, Francesco
    Perin, Alessandro
    Martegani, Alberto
    Aiani, Luca
    Solbiati, Luigi
    Lamperti, Massimo
    Casali, Cecilia
    Legnani, Federico
    Mattei, Luca
    Saladino, Andrea
    Saini, Marco
    DiMeco, Francesco
    NEUROSURGERY, 2014, 74 (05) : 542 - 552
  • [46] Baseline and Contrast-Enhanced Ultrasound of the Liver in Tumor Patients
    Oldenburg, A.
    Albrecht, T.
    ULTRASCHALL IN DER MEDIZIN, 2008, 29 (05): : 488 - 498
  • [47] Using Contrast-Enhanced Ultrasound for Brain Tumor Surgery
    Oliveira, Marcelo de Lima
    Picarelli, Helder
    Menezes, Marcos R.
    Teixeira, Manoel J.
    Bor-Seng-Shu, Edson
    NEUROSURGERY, 2015, 76 (01) : E104 - E105
  • [48] Brain tumor classification on intraoperative contrast-enhanced ultrasound
    Kai Ritschel
    Ioannis Pechlivanis
    Susanne Winter
    International Journal of Computer Assisted Radiology and Surgery, 2015, 10 : 531 - 540
  • [49] Contrast-enhanced ultrasound of breast tumors: an initial experience
    Kristiansen, Merete U.
    Martiniussen, Marit A.
    Larsen, Anne Sofie F.
    ACTA RADIOLOGICA OPEN, 2022, 11 (04)
  • [50] Contrast-enhanced ultrasound of breast fibromatosis: a case report
    Lin, Shanhong
    Cao, Yong
    Chen, Libin
    Chen, Mei
    Zhang, Shengmin
    Jia, Xiupeng
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2021, 49 (05)