Analysis of the accuracy of methods for the direct measurement of emissivity

被引:56
|
作者
Perez-Saez, Raul B. [1 ,2 ]
del Campo, Leire [1 ]
Tello, Manuel J. [1 ,2 ]
机构
[1] Univ Basque Country, Fac Ciencias & Tecnol, Dept Fis Mat Condensada, Leioa 48940, Bizkaia, Spain
[2] Univ Basque Country, Inst Sintesis & Estudio Mat, E-48080 Bilbao, Spain
关键词
direct measurement; emissivity; radiometry; systematic error;
D O I
10.1007/s10765-008-0402-4
中图分类号
O414.1 [热力学];
学科分类号
摘要
Emissivity measurements are of great interest for both theoretical studies and technological applications. Emissivity is a property that specifies how much radiation a real body emits as compared to a blackbody. The emissivity determination of a sample should be an easy task: a simple comparison between the sample and blackbody radiation at the same temperature. Unfortunately, when measuring the emissivity, some practical problems arise due to the differences between the true emitted radiation and the detected quantity. To clarify this point, an analysis of different direct methods for emissivity measurement is presented. Furthermore, a method that includes multiple reflections is developed. The systematic errors associated with each method are computed theoretically as a function of wavelength, sample temperature, and emissivity, and the surrounding enclosure temperature and emissivity. In general, the error is very high for small sample enclosures, but it strongly decreases when the enclosure area increases. Although at short wavelengths all the analyzed methods produce similar errors, noticeable differences appear under other conditions, and methods considering more radiation terms do not always produce lower errors.
引用
收藏
页码:1141 / 1155
页数:15
相关论文
共 50 条
  • [21] Correction Methods of Temperature Drift for Infrared Spectral Emissivity Measurement System
    Zhang Yu-feng
    Dai Jing-min
    Lu Xiao-dong
    Shao Zhu-feng
    Wu Yuan-qing
    [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36 (09) : 3003 - 3007
  • [22] Methods and results of measurement of reflectance and emissivity properties of spacecraft coatings and materials
    Vasiliev, VN
    [J]. PROCEEDINGS OF THE 9TH INTERNATIONAL SYMPOSIUM ON MATERIALS IN A SPACE ENVIRONMENT, 2003, 540 : 699 - 701
  • [23] ERROR ANALYSIS FOR EMISSIVITY MEASUREMENT USING FTIR SPECTROMETER
    Yan, Kai
    Ren, Huazhong
    Hu, Ronghai
    Mu, Xihan
    Liu, Zhao
    Yan, Guangjian
    [J]. 2013 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2013, : 3080 - 3083
  • [24] Accuracy, economy claimed for direct pipe measurement
    Leaversuch, RD
    [J]. MODERN PLASTICS, 1998, 75 (08): : 37 - 38
  • [25] Direct measurement of the accuracy of clock synchronisation algorithms
    Mackenzie, J
    Ashton, P
    [J]. PROCEEDINGS OF THE 21ST AUSTRALASIAN COMPUTER SCIENCE CONFERENCE, ACSC'98, 1998, 20 (01): : 563 - 574
  • [26] DIRECT MEASUREMENT OF SPECTRAL EMISSIVITY OF LIQUID SI IN THE RANGE OF VISIBLE-LIGHT
    TAKASUKA, E
    TOKIZAKI, E
    TERASHIMA, K
    KIMURA, S
    [J]. APPLIED PHYSICS LETTERS, 1995, 67 (02) : 152 - 154
  • [27] On the accuracy of direct forcing immersed boundary methods with projection methods
    Guy, Robert D.
    Hartenstine, David A.
    [J]. JOURNAL OF COMPUTATIONAL PHYSICS, 2010, 229 (07) : 2479 - 2496
  • [28] Emissivity measurement comparison
    Saxton, PC
    Moran, AL
    Rutledge, SK
    [J]. AMERICAN CERAMIC SOCIETY BULLETIN, 1999, 78 (10): : 55 - 58
  • [29] EMISSIVITY AND TEMPERATURE MEASUREMENT
    QUINN, TJ
    [J]. REVUE INTERNATIONALE DES HAUTES TEMPERATURES ET DES REFRACTAIRES, 1970, 7 (03): : 180 - +
  • [30] SPECTRAL EMISSIVITY MEASUREMENT
    DOMINGUEZ, KS
    WYNNYCKYJ, JR
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1989, 32 (08) : 1575 - 1580