Comparison of fire extinguishing performance of four halon substitutes and Halon 1301

被引:15
|
作者
Wang, Yawei [1 ]
Zou, Gaowan [1 ]
Liu, Conglin [1 ]
Gao, Y. [1 ]
机构
[1] Harbin Engn Univ, Coll Aerosp & Civil Engn, 145 Nantong St, Harbin 150001, Heilongjiang, Peoples R China
关键词
ISO9705; room; fire extinguishing tests; halon substitutes; fire extinguishing efficiency; OXYGEN-CONSUMPTION; HEAT RELEASE; AGENTS;
D O I
10.1177/07349041211030188
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The Halon 1301 fixed gas fire extinguishing system used in ship engine rooms has been banned from production all over the world, because halon destroys the ozone layer. Therefore, it is necessary to find an environmentally friendly, compatible and efficient alternative firefighting system. In this study, we performed fire extinguishing tests in an ISO9705 standard room for four alternative fire extinguishing agents, as well as Halon 1301. The fire extinguishing efficiency of each agent was determined based on its cooling effect, dilution effect of oxygen concentration, the extinguishing time of the oil pool fire and the re-ignition probability of the wood stack. The test results provide data support for the selection of alternatives of Halon 1301 from the aspect of fire extinguishing efficiency. Among these results, Novec 1230 had the best ability to put out the oil pool fire, and HFC-227ea suppressed the wood stack fire the best. The difference between the cooling ability of each fire extinguishing agent was small, and the inert gas (IG-541) displayed the best ability to dilute oxygen. Hot aerosol required the longest time to extinguish fire. Consequently, under the existing design standards, HFC-227ea had the better firefighting efficiency, more suitable to replace Halon 1301.
引用
收藏
页码:370 / 399
页数:30
相关论文
共 50 条
  • [1] AN ACCIDENTAL DISCHARGE OF A HALON 1301 TOTAL FLOODING FIRE EXTINGUISHING SYSTEM
    SASSKORTSAK, AM
    HOLNESS, DL
    STOPPS, GJ
    [J]. AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1985, 46 (11): : 670 - 673
  • [2] REVIEW ON TOXICOLOGICAL INVESTIGATIONS CONCERNING THE FIRE EXTINGUISHING AGENTS HALON-1301 AND HALON-1211 AND THEIR DECOMPOSITIONS PRODUCTS
    HUTTENHAIN, SH
    [J]. ZENTRALBLATT FUR HYGIENE UND UMWELTMEDIZIN, 1989, 189 (03): : 193 - 204
  • [3] Halon 1301 Fire Extinguishing Systems Pipeline Pressure Calculation Software Realization
    Rong, Jianzhong
    Tao, Tiejun
    Wang, Jian
    [J]. 2011 3RD WORLD CONGRESS IN APPLIED COMPUTING, COMPUTER SCIENCE, AND COMPUTER ENGINEERING (ACC 2011), VOL 4, 2011, 4 : 569 - +
  • [4] COMBAT SURVIVAL WITHOUT HALON-1301 - HALON AS A CFC ISSUE
    LEVY, R
    [J]. JOURNAL OF THE IES, 1992, 35 (05): : 14 - 14
  • [5] CFD investigation on flowing and discharging characteristics of airborne Halon 1301 fire-extinguishing agent at varied altitudes
    Yang, Qi
    Wang, Xinyu
    Liu, Jingjing
    Zhou, Xiaomeng
    Zhang, Haijun
    [J]. Case Studies in Thermal Engineering, 2024, 63
  • [6] Flammable Liquid Storerooms: Fire protection without Halon 1301
    Maranghides, A
    Sheinson, RS
    [J]. PROCESS SAFETY PROGRESS, 1999, 18 (01) : 31 - 34
  • [7] Impact of Pipe Diameter on the Discharge Process of Halon1301 in a Fire Extinguishing System with Horizontal Straight Pipe
    Chen, Ye
    Zhao, Chenxi
    Huang, Qiurui
    Li, Songyang
    Huang, Jiahui
    Ni, Xiaomin
    Wang, Jian
    [J]. FIRE-SWITZERLAND, 2023, 6 (08):
  • [8] USE OF HALON-1301 IN A HOSPITAL
    TOBACMAN, JK
    FORDHAM, L
    GEIGER, M
    [J]. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1984, 26 (09) : 632 - &
  • [9] TOXICOLOGICAL PROPERTIES OF HALON SUBSTITUTES
    SKAGGS, SR
    DIERDORF, DS
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 208 : 282 - ENVR
  • [10] HALON 1301 PROTECTS CITIBANK COMPUTERS
    不详