Flammable Liquid Storerooms: Fire protection without Halon 1301

被引:2
|
作者
Maranghides, A
Sheinson, RS
机构
[1] GEO Ctr Inc, Ft Washington, MD 20749 USA
[2] USN, Res Lab, Navy Technol Ctr Safety & Survivabil, Combust Dynam Sect, Washington, DC 20375 USA
关键词
D O I
10.1002/prs.680180107
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Flammable Liquid Storerooms (FLSRs) Pose a significant loss prevention challenge. The fire protection engineer must design the fire protection system for a very diverse fuel population. Furthermore, Sor military applications, provision must De made for In ige temperanture fluctuations in the operating environment and very strict suppression system space and weight requirements. Halon 1301 is a very, effective fire suppression agent used extensively in the military and commercial sectors for over. two decades. There are more than 2200 shipboard Halon 1301 fire suppression systems. However production of stratospheric ozone depleting halon has been banned but the Montreal Protocol and the U.S. Clean Air Act amendments since December 31, 1993.
引用
收藏
页码:31 / 34
页数:4
相关论文
共 38 条
  • [1] FIRE PROTECTION IN CHEMISTRY HOT CELLS BY USE OF HALON-1301
    FRANCK, TE
    YOUNGQUI.CH
    [J]. TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1967, 10 (02): : 679 - &
  • [2] Comparison of fire extinguishing performance of four halon substitutes and Halon 1301
    Wang, Yawei
    Zou, Gaowan
    Liu, Conglin
    Gao, Y.
    [J]. JOURNAL OF FIRE SCIENCES, 2021, 39 (05) : 370 - 399
  • [3] COMBAT SURVIVAL WITHOUT HALON-1301 - HALON AS A CFC ISSUE
    LEVY, R
    [J]. JOURNAL OF THE IES, 1992, 35 (05): : 14 - 14
  • [4] FIRE PROTECTION OF FLAMMABLE LIQUID RISKS BY FOAMS
    CORRIE, JG
    [J]. CHEMICAL ENGINEER-LONDON, 1974, (291): : 705 - 706
  • [5] FIRE PROTECTION OF FLAMMABLE LIQUID STORAGES WITH WATER SPRAYS
    NASH, P
    [J]. CHEMICAL ENGINEER-LONDON, 1974, (291): : 705 - 705
  • [6] AN ACCIDENTAL DISCHARGE OF A HALON 1301 TOTAL FLOODING FIRE EXTINGUISHING SYSTEM
    SASSKORTSAK, AM
    HOLNESS, DL
    STOPPS, GJ
    [J]. AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1985, 46 (11): : 670 - 673
  • [7] Halon 1301 Fire Extinguishing Systems Pipeline Pressure Calculation Software Realization
    Rong, Jianzhong
    Tao, Tiejun
    Wang, Jian
    [J]. 2011 3RD WORLD CONGRESS IN APPLIED COMPUTING, COMPUTER SCIENCE, AND COMPUTER ENGINEERING (ACC 2011), VOL 4, 2011, 4 : 569 - +
  • [8] REVIEW ON TOXICOLOGICAL INVESTIGATIONS CONCERNING THE FIRE EXTINGUISHING AGENTS HALON-1301 AND HALON-1211 AND THEIR DECOMPOSITIONS PRODUCTS
    HUTTENHAIN, SH
    [J]. ZENTRALBLATT FUR HYGIENE UND UMWELTMEDIZIN, 1989, 189 (03): : 193 - 204
  • [9] Seek alternative to halon for gas turbine fire protection
    Swanekamp, R
    [J]. POWER, 1996, 140 (02) : 54 - &
  • [10] USE OF HALON AND ALTERNATIVES FOR FIRE PROTECTION IN CONTROL ROOMS
    THORNTON, AJ
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1993, 29 (03) : 584 - 589